276 research outputs found
Recommended from our members
Development of interconnected silicon micro-evaporators for the on-detector electronics cooling of the future ITS detector in the ALICE experiment at LHC
This paper was presented at the 4th Micro and Nano Flows Conference (MNF2014), which was held at University College, London, UK. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute, ASME Press, LCN London Centre for Nanotechnology, UCL University College London, UCL Engineering, the International NanoScience Community, www.nanopaprika.eu.The design of the future High Energy Physics (HEP) particle detectors for the upgrade of the LHC (Large Hadron Collider) experiments at CERN (European Organization for Nuclear Research) is pushing technological frontiers to the limit trying to reach unprecedented accuracy in particles identification and particle production dynamics in ultra-relativistic hadron collisions. The thermal management of the on-detector electronics and the development of low mass integrated cooling systems have become a crucial task in the design of silicon tracking detectors for HEP applications. In this paper, we present a novel concept of low mass interconnected silicon microchannel devices for the future Inner Tracking System of the ALICE (A Large Ion Collider Experiment) detector at LHC. This innovative design achieves the requirements of the detector while minimizing the total material budget
Development of a cooling prototype for the CBM Silicon Tracking System
Traumatic brain injury (TBI) frequently occurs during childhood and adolescence with long-term neuropsychological and behavioral effects. Greater personal awareness of injury is associated with better outcomes. However, personal awareness is often assessed using ratings obtained from family members or significant others. Surprisingly, the accuracy of family-ratings compared with self-ratings has not been well studied in the TBI population. Thus, the purpose of this study was to examine self versus family-ratings of frontal dysfunction and secondly, the association between self/family reported frontal dysfunction and measured executive function outcomes. A total of 60 participants, approximately 10 years post-TBI, comprised 3 groups including; moderate/severe TBI (N=26; mean age 22.9, SD=3.0), mild TBI (N=20; mean age, 21.7, SD=2.7), and control (N=14: mean age, 21.6, SD=3.7). Neuropsychological testing was used to obtain domain scores for executive function and working memory/attention for each participant, and nominated family members and participants with TBI were asked to complete the Frontal Systems Behaviour Scale (FrSBe), consisting of three sub-scales; apathy, disinhibition, and executive dysfunction. Using the FrSBe there was no significant difference between the groups in executive function score, but the moderate/severe and mild groups had significantly lower working memory/attention scores compared with the control group (p<0.05). Repeated measures analysis of variance showed higher self-ratings on all sub-scales compared with family in each group (p<0.05). Scores on executive function and working memory/attention domains correlated with self, but not family reported executive dysfunction. Self-rated executive dysfunction explained 36% of the variance in executive function (p<0.001). While agreement between self-rated and family-rated total FrSBe scores was significant in all groups (p<0.001), our results showed that self-ratings were of higher predictive utility for executive functioning compared with family ratings. Further, at 10 years post-TBI, patients show greater awareness of deficits compared with family who rate consistently closer to the normal functioning range
Pathophysiology of Crohn’s disease inflammation and recurrence
Chron's Disease is a chronic inflammatory intestinal disease, first described at the beginning of the last century. The disease is characterized by the alternation of periods of flares and remissions influenced by a complex pathogenesis in which inflammation plays a key role. Crohn's disease evolution is mediated by a complex alteration of the inflammatory response which is characterized by alterations of the innate immunity of the intestinal mucosa barrier together with a remodeling of the extracellular matrix through the expression of metalloproteins and increased adhesion molecules expression, such as MAcCAM-1. This reshaped microenvironment enhances leucocytes migration in the sites of inflammation, promoting a TH1 response, through the production of cytokines such as IL-12 and TNF-α. IL-12 itself and IL-23 have been targeted for the medical treatment of CD. Giving the limited success of medical therapies, the treatment of the disease is invariably surgical. This review will highlight the role of inflammation in CD and describe the surgical approaches for the prevention of the almost inevitable recurrence
Performance of the CMS Cathode Strip Chambers with Cosmic Rays
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device
in the CMS endcaps. Their performance has been evaluated using data taken
during a cosmic ray run in fall 2008. Measured noise levels are low, with the
number of noisy channels well below 1%. Coordinate resolution was measured for
all types of chambers, and fall in the range 47 microns to 243 microns. The
efficiencies for local charged track triggers, for hit and for segments
reconstruction were measured, and are above 99%. The timing resolution per
layer is approximately 5 ns
Performance and Operation of the CMS Electromagnetic Calorimeter
The operation and general performance of the CMS electromagnetic calorimeter
using cosmic-ray muons are described. These muons were recorded after the
closure of the CMS detector in late 2008. The calorimeter is made of lead
tungstate crystals and the overall status of the 75848 channels corresponding
to the barrel and endcap detectors is reported. The stability of crucial
operational parameters, such as high voltage, temperature and electronic noise,
is summarised and the performance of the light monitoring system is presented
Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to neq/cm. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trapping rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trapping rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trapping rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations
Test beam performance measurements for the Phase I upgrade of the CMS pixel detector
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is (99.95 ± 0.05) %, while the intrinsic spatial resolutions are (4.80 ± 0.25) μm and (7.99 ± 0.21) μm along the 100 μm and 150 μm pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.Peer reviewe
Time for a paradigm shift in shared decision-making in trauma and emergency surgery? Results from an international survey
Background: Shared decision-making (SDM) between clinicians and patients is one of the pillars of the modern patient-centric philosophy of care. This study aims to explore SDM in the discipline of trauma and emergency surgery, investigating its interpretation as well as the barriers and facilitators for its implementation among surgeons. Methods: Grounding on the literature on the topics of the understanding, barriers, and facilitators of SDM in trauma and emergency surgery, a survey was created by a multidisciplinary committee and endorsed by the World Society of Emergency Surgery (WSES). The survey was sent to all 917 WSES members, advertised through the society’s website, and shared on the society’s Twitter profile. Results: A total of 650 trauma and emergency surgeons from 71 countries in five continents participated in the initiative. Less than half of the surgeons understood SDM, and 30% still saw the value in exclusively engaging multidisciplinary provider teams without involving the patient. Several barriers to effectively partnering with the patient in the decision-making process were identified, such as the lack of time and the need to concentrate on making medical teams work smoothly. Discussion: Our investigation underlines how only a minority of trauma and emergency surgeons understand SDM, and perhaps, the value of SDM is not fully accepted in trauma and emergency situations. The inclusion of SDM practices in clinical guidelines may represent the most feasible and advocated solutions
- …