128 research outputs found
Epizootiological-and-Epidemiological Situation in Natural Tularemia Foci of the Siberian and Far Eastern Federal Districts in 2011, and Prognosis for 2012
Presented is a piece of information about the situation in natural tularemia foci and human morbidity in the territory of Siberia and Far East in 2011. Outlined is the prognosis of epizootic situation for 2012. In 2011, sporadic morbidity was registered in the Novosibirsk, Tomsk, Kemerovo, and Omsk Regions. Isolated cases of the disease were identified in the Altai Territory, in the Khanty-Mansiisk autonomous district, and the Sakhalin Region. Specified is the fact that in 2011 epizooties were of a local scale, and the situation on tularemia on the whole was favorable. Nevertheless, the possibility of aggravation of the situation in some territories in 2012 is not ruled out completely
Status of the Super-B factory Design
The SuperB international team continues to optimize the design of an
electron-positron collider, which will allow the enhanced study of the origins
of flavor physics. The project combines the best features of a linear collider
(high single-collision luminosity) and a storage-ring collider (high repetition
rate), bringing together all accelerator physics aspects to make a very high
luminosity of 10 cm sec. This asymmetric-energy collider
with a polarized electron beam will produce hundreds of millions of B-mesons at
the (4S) resonance. The present design is based on extremely low
emittance beams colliding at a large Piwinski angle to allow very low
without the need for ultra short bunches. Use of crab-waist
sextupoles will enhance the luminosity, suppressing dangerous resonances and
allowing for a higher beam-beam parameter. The project has flexible beam
parameters, improved dynamic aperture, and spin-rotators in the Low Energy Ring
for longitudinal polarization of the electron beam at the Interaction Point.
Optimized for best colliding-beam performance, the facility may also provide
high-brightness photon beams for synchrotron radiation applications
Analysis of the Epizootiological Situation in the Amur Region in Autumn, 2013 Formed under the Influence of High Water over the Small Mammals
Objective of the work was to estimate the number and state of the small mammal populations after the summer flood, 2013 in the territory of the Amur Region and make short-term forecasting of the epidemiological situation development. Carried out was small animals capturing using Gero traps with bread as a bait. Epizootiological surveillance in August-September 2013 indicated that the numbers of small mammals did not differ from the average annual rates, but the process of active reproduction in the populations was being underway. In October-November a sharp increase in the animal abundance rate was registered, reproduction process terminated. Large-scale flooding resulted in the formation of local settlements with a high animal density. Stress, aggressiveness and food ration change along with seasonal migration of rodents into human buildings predetermined epizootiological and epidemiological premises for onset of natural-focal infections. Therewith the conclusion was made up that it was necessary to perform epizootiological monitoring of the small mammal populations and realization of measures aimed at the rodent extermination in human settlements in 2014
EPIDEMIOLOGICAL AND EPIZOOTIOLOGICAL ANALYSIS OF THE SITUATION ON TULAREMIA IN THE RUSSIAN FEDERATION IN 2016 AND FORECAST FOR 2017
123 cases of human infection with Francisella tularensis were registered in the territory of the Russian Federation in 2016. 90 % of the total number was reported by three Federal Districts: North-Western, Siberian, and Central ones. Epizootic manifestations of varying intensity were detected in 56 regions. A considerable number of tularemia cases were observed in the Republic of Karelia, Nenets Autonomous District, Omsk and Ryazan Regions, and in Saint-Petersburg. Conspicuous are some recent peculiarities of tularemia manifestations: non-specificity of clinical symptoms, especially at early stages of the disease, their increasing variability against the background of mixed infections with tularemia and other natural-focal infections agents. The most expressed symptoms are fever and lymphatic adenitis; the patients are diagnosed with tularemia during initial days of the sought treatment in 40-45 % of the cases. Based on the data on morbidity rates in humans, epizootiological condition of natural tularemia foci, the numbers of isolated cultures and incidence of the vectors and carriers of the agent, as well as taking into consideration the scope of preventive vaccination in the regions, identified were the territories in which epidemic complication are most likely to occur in 2017
Precise measurement of and between 1.84 and 3.72 GeV at the KEDR detector
The present work continues a series of the KEDR measurements of the value
that started in 2010 at the VEPP-4M collider. By combining new data
with our previous results in this energy range we measured the values of
and at nine center-of-mass energies between 3.08 and 3.72
GeV. The total accuracy is about or better than at most of energy
points with a systematic uncertainty of about . Together with the
previous precise measurement at KEDR in the energy range 1.84-3.05 GeV, it
constitutes the most detailed high-precision measurement near the
charmonium production threshold.Comment: arXiv admin note: text overlap with arXiv:1610.02827 and substantial
text overlap with arXiv:1510.0266
Measurement of decay rate and parameters at KEDR
Using the inclusive photon spectrum based on a data sample collected at the
peak with the KEDR detector at the VEPP-4M collider, we
measured the rate of the radiative decay as well
as mass and width. Taking into account an asymmetric photon
lineshape we obtained keV, MeV/, MeV.Comment: 6 pages, 3 figure
Measurement of J/psi to eta_c gamma at KEDR
We present a study of the inclusive photon spectra from 5.9 million J/psi
decays collected with the KEDR detector at the VEPP-4M e+e- collider. We
measure the branching fraction of radiative decay J/psi to eta_c gamma, eta_c
width and mass. Our preliminary results are: M(eta_c) = 2979.4+-1.5+-1.9 MeV,
G(eta_c) = 27.8+-5.1+-3.3 MeV, B(J/psi to eta_c gamma) = (2.34+-0.15+-0.40)%.Comment: To be published in Proceedings of the PhiPsi09, Oct. 13-16, 2009,
Beijing, Chin
Measurement of B(J/psi->eta_c gamma) at KEDR
We present a study of the inclusive photon spectrum from 6.3 million J/psi
decays collected with the KEDR detector at the VEPP-4M e+e- collider. We
measure the branching fraction of the radiative decay J/psi -> eta_c gamma,
eta_c width and mass. Taking into account an asymmetric photon line shape we
obtain: M(eta_c) = (2978.1 +- 1.4 +- 2.0) MeV/c^2, Gamma(eta_c) = (43.5 +- 5.4
+- 15.8) MeV, B(J/psi->eta_c gamma) = (2.59 +- 0.16 +- 0.31)%$.Comment: 6 pages, 1 figure. To be published in the proceedings of the 4th
International Workshop on Charm Physics (Charm2010), October 21-24, 2010,
IHEP, Beijin
SuperB: next-generation e+e- B-factory collider
International audienceThe SuperB international team continues to optimize the design of an electron-positron collider, which will allow the enhanced study of the origins of ïŹavor physics. The project combines the best features of a linear collider (high single- collision luminosity) and a storage-ring collider (high rep- etition rate), bringing together all accelerator physics as- pects to make a very high luminosity of 10^36 cm^â2 sec^â1 . This asymmetric-energy collider with a polarized electron beam will produce hundreds of millions of B-mesons at the ΄(4S) resonance. The present design is based on ex- tremely low emittance beams colliding at a large Piwin- ski angle to allow very low ÎČây without the need for ultra short bunches. Use of crab-waist sextupoles will enhance the luminosity, suppressing dangerous resonances and al- lowing for a higher beam-beam parameter. The project has ïŹexible beam parameters, improved dynamic aperture, and spin-rotators in the Low Energy Ring for longitudinal po- larization of the electron beam at the Interaction Point. Op- timized for best colliding-beam performance, the facility may also provide high-brightness photon beams for syn- chrotron radiation applications
- âŠ