8,693 research outputs found
DT Sector Collector electronics design and construction
The CMS detector at LHC is equipped with Drift Tubes (DT) chambers for muon detection and triggering in the barrel region. The Sector Collector (SC) modules collect the track segments reconstructed by on-chamber trigger electronics. Data from different chambers are aligned in time and sent to the subsequent reconstruction processors via optical links. Several FPGA devices performing the processing of the data were designed in VHDL, including spy features to monitor the trigger data flow. A test jig was set up with custom hardware and software in order to fully validate final production boards. Installation and commissioning in CMS provided first experience with the synchronization and monitoring tools
Perfil dos consumidores de produtos orgânicos no Distrito Federal.
bitstream/item/103085/1/cot-40.pd
Recommended from our members
Personalized Genetic Risk Counseling to Motivate Diabetes Prevention: A randomized trial
OBJECTIVE To examine whether diabetes genetic risk testing and counseling can improve diabetes prevention behaviors. RESEARCH DESIGN AND METHODS We conducted a randomized trial of diabetes genetic risk counseling among overweight patients at increased phenotypic risk for type 2 diabetes. Participants were randomly allocated to genetic testing versus no testing. Genetic risk was calculated by summing 36 single nucleotide polymorphisms associated with type 2 diabetes. Participants in the top and bottom score quartiles received individual genetic counseling before being enrolled with untested control participants in a 12-week, validated, diabetes prevention program. Middle-risk quartile participants were not studied further. We examined the effect of this genetic counseling intervention on patient self-reported attitudes, program attendance, and weight loss, separately comparing higher-risk and lower-risk result recipients with control participants. RESULTS The 108 participants enrolled in the diabetes prevention program included 42 participants at higher diabetes genetic risk, 32 at lower diabetes genetic risk, and 34 untested control subjects. Mean age was 57.9 ± 10.6 years, 61% were men, and average BMI was 34.8 kg/m2, with no differences among randomization groups. Participants attended 6.8 ± 4.3 group sessions and lost 8.5 ± 10.1 pounds, with 33 of 108 (30.6%) losing ≥5% body weight. There were few statistically significant differences in self-reported motivation, program attendance, or mean weight loss when higher-risk recipients and lower-risk recipients were compared with control subjects (P > 0.05 for all but one comparison). CONCLUSIONS Diabetes genetic risk counseling with currently available variants does not significantly alter self-reported motivation or prevention program adherence for overweight individuals at risk for diabetes
Status of the Super-B factory Design
The SuperB international team continues to optimize the design of an
electron-positron collider, which will allow the enhanced study of the origins
of flavor physics. The project combines the best features of a linear collider
(high single-collision luminosity) and a storage-ring collider (high repetition
rate), bringing together all accelerator physics aspects to make a very high
luminosity of 10 cm sec. This asymmetric-energy collider
with a polarized electron beam will produce hundreds of millions of B-mesons at
the (4S) resonance. The present design is based on extremely low
emittance beams colliding at a large Piwinski angle to allow very low
without the need for ultra short bunches. Use of crab-waist
sextupoles will enhance the luminosity, suppressing dangerous resonances and
allowing for a higher beam-beam parameter. The project has flexible beam
parameters, improved dynamic aperture, and spin-rotators in the Low Energy Ring
for longitudinal polarization of the electron beam at the Interaction Point.
Optimized for best colliding-beam performance, the facility may also provide
high-brightness photon beams for synchrotron radiation applications
Simvastatin inhibits TLR8 signaling in primary human monocytes and spontaneous TNF production from rheumatoid synovial membrane cultures
Simvastatin has been shown to have anti-inflammatory effects that are independent of its serum cholesterol lowering action, but the mechanisms by which these anti-inflammatory effects are mediated have not been elucidated. To explore the mechanism involved, the effect of simvastatin on Toll-like receptor (TLR) signalling in primary human monocytes was investigated. A short pre-treatment with simvastatin dose-dependently inhibited the production of tumor necrosis factor-α (TNF) in response to TLR8 (but not TLRs 2, 4, or 5) activation. Statins are known inhibitors of the cholesterol biosynthetic pathway, but intriguingly TLR8 inhibition could not be reversed by addition of mevalonate or geranylgeranyl pyrophosphate; downstream products of cholesterol biosynthesis. TLR8 signalling was examined in HEK 293 cells stably expressing TLR8, where simvastatin inhibited IKKα/β phosphorylation and subsequent NF-κB activation without affecting the pathway to AP-1. Since simvastatin has been reported to have anti-inflammatory effects in RA patients and TLR8 signalling contributes to TNF production in human RA synovial tissue in culture, simvastatin was tested in these cultures. Simvastatin significantly inhibited the spontaneous release of TNF in this model which was not reversed by mevalonate. Together, these results demonstrate a hitherto unrecognized mechanism of simvastatin inhibition of TLR8 signalling that may in part explain its beneficial anti-inflammatory effects
Measurement of the branching fraction for the decay KS --> pi e nu
We present a measurement of the branching ratio BR(KS --> pi e nu) performed
using the KLOE detector. KS mesons are produced in the reaction e+ e- --> phi
--> KS KL at the DAFNE collider. In a sample of about 5 million KS-tagged
events we find 624 +- 30 semileptonic KS decays. Normalizing to the KS --> pi+
pi- count in the same data sample, we obtain BR(KS --> pi e nu) = (6.91 +-
0.37) 10^-4, in agreement with the Standard Model expectation.Comment: 9 pages, 5 Encapsulated Postscript figures. Submitted to Phys. Lett.
Study of the Decay phi --> eta pi0 gamma with the KLOE detector
In a sample of 5.3x10^7 phi-decays observed with the KLOE detector at the
Frascati phi-factory Dafne we find 605 eta pi0 gamma events with eta -->
gamma\gamma and 197 eta pi0 gamma events with eta --> pi+ pi- pi0. The decay
phi --> eta pi0 gamma is dominated by the process phi --> a0 gamma. From a fit
to the eta pi0 mass spectrum we find BR(phi --> ao(980) gamma)= (7.4 +-
0.7)x10^-5.Comment: 12 pages, 6 figures, submitted to Phys.Lett.
A novel application of Fiber Bragg Grating (FBG) sensors in MPGD
We present a novel application of Fiber Bragg Grating (FBG) sensors in the
construction and characterisation of Micro Pattern Gaseous Detector (MPGD),
with particular attention to the realisation of the largest triple (Gas
electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the
CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of
about 0.5 m2 active area each, employing three GEM foils per chamber, to be
installed in the forward region of the CMS endcap during the long shutdown of
LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM
foils that are mechanically stretched in order to secure their flatness and the
consequent uniform performance of the GE1/1 chamber across its whole active
surface. So far FBGs have been used in high energy physics mainly as high
precision positioning and re-positioning sensors and as low cost, easy to
mount, low space consuming temperature sensors. FBGs are also commonly used for
very precise strain measurements in material studies. In this work we present a
novel use of FBGs as flatness and mechanical tensioning sensors applied to the
wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used
to determine the optimal mechanical tension applied and to characterise the
mechanical tension that should be applied to the foils. We discuss the results
of the test done on a full-sized GE1/1 final prototype, the studies done to
fully characterise the GEM material, how this information was used to define a
standard assembly procedure and possible future developments.Comment: 4 pages, 4 figures, presented by Luigi Benussi at MPGD 2015 (Trieste,
Italy). arXiv admin note: text overlap with arXiv:1512.0848
- …