190 research outputs found

    Performance of the PADME calorimeter prototype at the DAΦ\PhiNE BTF

    Full text link
    The PADME experiment at the DAΦ\PhiNE Beam-Test Facility (BTF) aims at searching for invisible decays of the dark photon by measuring the final state missing mass in the process e+e−→γ+A′e^+e^- \to \gamma+ A', with A′A' undetected. The measurement requires the determination of the 4-momentum of the recoil photon, performed using a homogeneous, highly segmented BGO crystals calorimeter. We report the results of the test of a 5×\times5 crystals prototype performed with an electron beam at the BTF in July 2016

    The Frascati Beam Test Facility

    Full text link
    From 2004 the Frascati Beam Test Facility (BTF) in the DAFNE accelerator complex provides to the external user up to 1E10 electrons per bunch or up to 10E9 positrons per bunch to develop their detectors. After an upgrade program terminated in 2020 of the beam test facility a description of the status and available beam lines will be done.Comment: Talk presented at the International Workshop on Future Linear Colliders (LCWS 2023), 15-19 May 2023. C23-05-15.

    Performance of the diamond active target prototype for the PADME experiment at the DAΦ\PhiNE BTF

    Full text link
    The PADME experiment at the DAΦ\PhiNE Beam-Test Facility (BTF) is designed to search for the gauge boson of a new U(1)\rm U(1) interaction in the process e+^+e−→γ^-\rightarrow\gamma+A′\rm A', using the intense positron beam hitting a light target. The A′\rm A', usually referred as dark photon, is assumed to decay into invisible particles of a secluded sector and it can be observed by searching for an anomalous peak in the spectrum of the missing mass measured in events with a single photon in the final state. The measurement requires the determination of the 4-momentum of the recoil photon, performed by a homogeneous, highly segmented BGO crystals calorimeter. A significant improvement of the missing mass resolution is possible using an active target capable to determine the average position of the positron bunch with a resolution of less than 1 mm. This report presents the performance of a real size (2x2cm2)\rm (2x2 cm^2) PADME active target made of a thin (50 μ\mum) diamond sensor, with graphitic strips produced via laser irradiation on both sides. The measurements are based on data collected in a beam test at the BTF in November 2015.Comment: 7 pages, 10 figure

    The Frascati LINAC beam test facility performances and upgrades

    Get PDF
    The Beam-Test Facility (BTF) of the DAΦNE accelerator complex, in the Frascati National Laboratory of the INFN is in operation since 2004 for the high-energy particle and accelerator community. The performance of the BTF is discussed and the plans for the future upgrade of the facility are introduced

    Exploring a New Paradigm for Accelerators and Large Experimental Apparatus Control Systems

    Full text link
    International audienceThe integration of web technologies and web services has been, in the recent years, one of the major trends in upgrading and developing control systems for accelerators and large experimental apparatuses. Usually, web technologies have been introduced to complement the control systems with smart add-ons and user friendly services or, for instance, to safely allow access to the control system to users from remote sites. In spite of this still narrow spectrum of employment, some software technologies developed for high performance web services, although originally intended and optimized for these particular applications, deserve some features that would allow their deeper integration in a control system and, eventually, use them to develop some of the control system's core components. In this paper we present the conclusion of the preliminary investigations of a new paradigm for an accelerator control system and associated machine data acquisition system (DAQ), based on a synergic combination of network distributed cache memory and a non-relational key/value database. We investigated these technologies with particular interest on performances, namely speed of data storage and retrieve for the network memory, data throughput and queries execution time for the database and, especially, how much this performances can benefit from their inherent scalability. The work has been developed in a collaboration between INFN-LNF and INFN-Roma Tor Vergata

    Characterization and Performance of PADME's Cherenkov-Based Small-Angle Calorimeter

    Full text link
    The PADME experiment, at the Laboratori Nazionali di Frascati (LNF), in Italy, will search for invisible decays of the hypothetical dark photon via the process e+e−→γA′e^+e^-\rightarrow \gamma A', where the A′A' escapes detection. The dark photon mass range sensitivity in a first phase will be 1 to 24 MeV. We report here on measurement and simulation studies of the performance of the Small-Angle Calorimeter, a component of PADME's detector dedicated to rejecting 2- and 3-gamma backgrounds. The crucial requirement is a timing resolution of less than 200 ps, which is satisfied by the choice of PbF2_2 crystals and the newly released Hamamatsu R13478UV photomultiplier tubes (PMTs). We find a timing resolution of 81 ps (with double-peak separation resolution of 1.8 ns) and a single-crystal energy resolution of 5.7%/E\sqrt{E} with light yield of 2.07 photo-electrons per MeV, using 100 to 400 MeV electrons at the Beam Test Facility of LNF. We also propose the investigation of a two-PMT solution coupled to a single PbF2_2 crystal for higher-energy applications, which has potentially attractive features.Comment: 12 pages, 19 figures. v2: added section on radiation damage studie

    The Microcalorimeter Arrays for a Rhenium Experiment (MARE): a next-generation calorimetric neutrino mass experiment

    Full text link
    Neutrino oscillation experiments have proved that neutrinos are massive particles, but can't determine their absolute mass scale. Therefore the neutrino mass is still an open question in elementary particle physics. An international collaboration is growing around the project of Microcalorimeter Arrays for a Rhenium Experiment (MARE) for directly measuring the neutrino mass with a sensitivity of about 0.2eV/c2. Many groups are joining their experiences and technical expertise in a common effort towards this challenging experiment. We discuss the different scenarios and the impact of MARE as a complement of KATRIN.Comment: 3 pages, 1 figure Nucl. Instr. Meth. A, proceedings of LTD11 workshop, Tokyo 200

    The Air Microwave Yield (AMY) experiment - A laboratory measurement of the microwave emission from extensive air showers

    Full text link
    The AMY experiment aims to measure the microwave bremsstrahlung radiation (MBR) emitted by air-showers secondary electrons accelerating in collisions with neutral molecules of the atmosphere. The measurements are performed using a beam of 510 MeV electrons at the Beam Test Facility (BTF) of Frascati INFN National Laboratories. The goal of the AMY experiment is to measure in laboratory conditions the yield and the spectrum of the GHz emission in the frequency range between 1 and 20 GHz. The final purpose is to characterise the process to be used in a next generation detectors of ultra-high energy cosmic rays. A description of the experimental setup and the first results are presented.Comment: 3 pages -- EPS-HEP'13 European Physical Society Conference on High Energy Physics (July, 18-24, 2013) at Stockholm, Swede

    Double-beta decay of 130^{130}Te to the first 0+^{+} excited state of 130^{130}Xe with CUORICINO

    Get PDF
    The CUORICINO experiment was an array of 62 TeO2_{2} single-crystal bolometers with a total 130^{130}Te mass of 11.3 11.3\,kg. The experiment finished in 2008 after more than 3 years of active operating time. Searches for both 0ν0\nu and 2ν2\nu double-beta decay to the first excited 0+0^{+} state in 130^{130}Xe were performed by studying different coincidence scenarios. The analysis was based on data representing a total exposure of N(130^{130}Te)⋅\cdott=9.5×1025 9.5\times10^{25}\,y. No evidence for a signal was found. The resulting lower limits on the half lives are T1/22ν(130Te→130Xe∗)>1.3×1023 T^{2\nu}_{1/2}(^{130} Te\rightarrow^{130} Xe^{*})>1.3\times10^{23}\,y (90% C.L.), and T1/20ν(130Te→130Xe∗)>9.4×1023 T^{0\nu}_{1/2}(^{130} Te\rightarrow^{130} Xe^{*})>9.4\times10^{23}\,y (90% C.L.).Comment: 6 pages, 4 figure
    • …
    corecore