Design and construction of a carbon fiber gondola for the SPIDER balloon-borne telescope
We introduce the light-weight carbon fiber and aluminum gondola designed for
the SPIDER balloon-borne telescope. SPIDER is designed to measure the
polarization of the Cosmic Microwave Background radiation with unprecedented
sensitivity and control of systematics in search of the imprint of inflation: a
period of exponential expansion in the early Universe. The requirements of this
balloon-borne instrument put tight constrains on the mass budget of the
payload. The SPIDER gondola is designed to house the experiment and guarantee
its operational and structural integrity during its balloon-borne flight, while
using less than 10% of the total mass of the payload. We present a construction
method for the gondola based on carbon fiber reinforced polymer tubes with
aluminum inserts and aluminum multi-tube joints. We describe the validation of
the model through Finite Element Analysis and mechanical tests.Comment: 16 pages, 11 figures. Presented at SPIE Ground-based and Airborne
Telescopes V, June 23, 2014. To be published in Proceedings of SPIE Volume
914
The Thermal Design, Characterization, and Performance of the SPIDER Long-Duration Balloon Cryostat
We describe the SPIDER flight cryostat, which is designed to cool six
millimeter-wavelength telescopes during an Antarctic long-duration balloon
flight. The cryostat, one of the largest to have flown on a stratospheric
payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6
K. Stainless steel capillaries facilitate a high flow impedance connection
between the main liquid helium tank and a smaller superfluid tank, allowing the
latter to operate at 1.6 K as long as there is liquid in the 4.2 K main tank.
Each telescope houses a closed cycle helium-3 adsorption refrigerator that
further cools the focal planes down to 300 mK. Liquid helium vapor from the
main tank is routed through heat exchangers that cool radiation shields,
providing negative thermal feedback. The system performed successfully during a
17 day flight in the 2014-2015 Antarctic summer. The cryostat had a total hold
time of 16.8 days, with 15.9 days occurring during flight.Comment: 15 pgs, 17 fig
Design of 280 GHz feedhorn-coupled TES arrays for the balloon-borne polarimeter SPIDER
We describe 280 GHz bolometric detector arrays that instrument the
balloon-borne polarimeter SPIDER. A primary science goal of SPIDER is to
measure the large-scale B-mode polarization of the cosmic microwave background
in search of the cosmic-inflation, gravitational-wave signature. 280 GHz
channels aid this science goal by constraining the level of B-mode
contamination from galactic dust emission. We present the focal plane unit
design, which consists of a 1616 array of conical, corrugated feedhorns
coupled to a monolithic detector array fabricated on a 150 mm diameter silicon
wafer. Detector arrays are capable of polarimetric sensing via waveguide
probe-coupling to a multiplexed array of transition-edge-sensor (TES)
bolometers. The SPIDER receiver has three focal plane units at 280 GHz, which
in total contains 765 spatial pixels and 1,530 polarization sensitive
bolometers. By fabrication and measurement of single feedhorns, we demonstrate
14.7 FHWM Gaussian-shaped beams with 1% ellipticity in a 30%
fractional bandwidth centered at 280 GHz. We present electromagnetic
simulations of the detection circuit, which show 94% band-averaged,
single-polarization coupling efficiency, 3% reflection and 3% radiative loss.
Lastly, we demonstrate a low thermal conductance bolometer, which is
well-described by a simple TES model and exhibits an electrical noise
equivalent power (NEP) = 2.6 10 W/,
consistent with the phonon noise prediction.Comment: Proceedings of SPIE Astronomical Telescopes + Instrumentation 201
280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2 Suborbital Polarimeter
We describe the construction and characterization of the 280 GHz bolometric
focal plane units (FPUs) to be deployed on the second flight of the
balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary
science goal of detecting or placing an upper limit on the amplitude of the
primordial gravitational wave signature in the cosmic microwave background
(CMB) by constraining the B-mode contamination in the CMB from Galactic dust
emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated
silicon feedhorns coupled to an array of aluminum-manganese transition-edge
sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the
three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial
pixels) optimized for the low loading environment in flight and read out by
time-division SQUID multiplexing. In this paper we describe the mechanical,
thermal, and magnetic shielding architecture of the focal planes and present
cryogenic measurements which characterize yield and the uniformity of several
bolometer parameters. The assembled FPUs have high yields, with one array as
high as 95% including defects from wiring and readout. We demonstrate high
uniformity in device parameters, finding the median saturation power for each
TES array to be ~3 pW at 300 mK with a less than 6% variation across each array
at one standard deviation. These focal planes will be deployed alongside the 95
and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo
Station in Antarctica in December 2018
A Measurement of the CMB Temperature Power Spectrum and Constraints on Cosmology from the SPT-3G 2018 TT/TE/EE Data Set
We present a sample-variance-limited measurement of the temperature power
spectrum () of the cosmic microwave background (CMB) using observations of
a field made by SPT-3G in 2018. We report
multifrequency power spectrum measurements at 95, 150, and 220GHz covering the
angular multipole range . We combine this
measurement with the published polarization power spectrum measurements from
the 2018 observing season and update their associated covariance matrix to
complete the SPT-3G 2018 data set. This is the first analysis to
present cosmological constraints from SPT , , and power spectrum
measurements jointly. We blind the cosmological results and subject the data
set to a series of consistency tests at the power spectrum and parameter level.
We find excellent agreement between frequencies and spectrum types and our
results are robust to the modeling of astrophysical foregrounds. We report
results for CDM and a series of extensions, drawing on the following
parameters: the amplitude of the gravitational lensing effect on primary power
spectra , the effective number of neutrino species
, the primordial helium abundance , and the
baryon clumping factor due to primordial magnetic fields . We find that the
SPT-3G 2018 data are well fit by CDM with a
probability-to-exceed of . For CDM, we constrain the expansion
rate today to and the
combined structure growth parameter to . The SPT-based
results are effectively independent of Planck, and the cosmological parameter
constraints from either data set are within of each other.
(abridged)Comment: 35 Pages, 17 Figures, 11 Table
The Design and Integrated Performance of SPT-3G
SPT-3G is the third survey receiver operating on the South Pole Telescope
dedicated to high-resolution observations of the cosmic microwave background
(CMB). Sensitive measurements of the temperature and polarization anisotropies
of the CMB provide a powerful dataset for constraining cosmology. Additionally,
CMB surveys with arcminute-scale resolution are capable of detecting galaxy
clusters, millimeter-wave bright galaxies, and a variety of transient
phenomena. The SPT-3G instrument provides a significant improvement in mapping
speed over its predecessors, SPT-SZ and SPTpol. The broadband optics design of
the instrument achieves a 430 mm diameter image plane across observing bands of
95 GHz, 150 GHz, and 220 GHz, with 1.2 arcmin FWHM beam response at 150 GHz. In
the receiver, this image plane is populated with 2690 dual-polarization,
tri-chroic pixels (~16000 detectors) read out using a 68X digital
frequency-domain multiplexing readout system. In 2018, SPT-3G began a multiyear
survey of 1500 deg of the southern sky. We summarize the unique optical,
cryogenic, detector, and readout technologies employed in SPT-3G, and we report
on the integrated performance of the instrument.Comment: 25 pages, 11 figures. Submitted to ApJ
Constraints on CDM Extensions from the SPT-3G 2018 and Power Spectra
We present constraints on extensions to the CDM cosmological model
from measurements of the -mode polarization auto-power spectrum and the
temperature--mode cross-power spectrum of the cosmic microwave background
(CMB) made using 2018 SPT-3G data. The extensions considered vary the
primordial helium abundance, the effective number of relativistic degrees of
freedom, the sum of neutrino masses, the relativistic energy density and mass
of a sterile neutrino, and the mean spatial curvature. We do not find clear
evidence for any of these extensions, from either the SPT-3G 2018 dataset alone
or in combination with baryon acoustic oscillation and \textit{Planck} data.
None of these model extensions significantly relax the tension between
Hubble-constant, , constraints from the CMB and from distance-ladder
measurements using Cepheids and supernovae. The addition of the SPT-3G 2018
data to \textit{Planck} reduces the square-root of the determinants of the
parameter covariance matrices by factors of across these models,
signaling a substantial reduction in the allowed parameter volume. We also
explore CMB-based constraints on from combined SPT, \textit{Planck}, and
ACT DR4 datasets. While individual experiments see some indications of
different values between the , , and spectra, the combined
constraints are consistent between the three spectra. For the full
combined datasets, we report , which is the tightest constraint on
from CMB power spectra to date and in tension with the most
precise distance-ladder-based measurement of . The SPT-3G survey is
planned to continue through at least 2023, with existing maps of combined 2019
and 2020 data already having lower noise than the maps used in
this analysis.Comment: Submitted to PRD; 19 pages, 7 figure
Performance and characterization of the SPT-3G digital frequency-domain multiplexed readout system using an improved noise and crosstalk model
The third generation South Pole Telescope camera (SPT-3G) improves upon its predecessor (SPTpol) by an order of magnitude increase in detectors on the focal plane. The technology used to read out and control these detectors, digital frequency-domain multiplexing (DfMUX), is conceptually the same as used for SPTpol, but extended to accommodate more detectors. A nearly 5x expansion in the readout operating bandwidth has enabled the use of this large focal plane, and SPT-3G performance meets the forecasting targets relevant to its science objectives. However, the electrical dynamics of the higher-bandwidth readout differ from predictions based on models of the SPTpol system. To address this, we present an updated derivation for electrical crosstalk in higher-bandwidth DfMUX systems, and identify two previously uncharacterized contributions to readout noise. The updated crosstalk and noise models successfully describe the measured crosstalk and readout noise performance of SPT-3G, and suggest improvements to the readout system for future experiments using DfMUX, such as the LiteBIRD space telescope
- …