1,198 research outputs found

    Does Anyone Remember Fingerprints on an X-Ray?

    Get PDF

    Doppler Contrast Echocardiography

    Get PDF

    Tricuspid annular plane systolic excursion (TAPSE) revisited using CMR

    Get PDF
    This observational pilot project was performed as background to eventually create a rapid, automated and accurate assessment of RV systolic function in variable clinical subgroups. We propose new parameters that characterize the global systolic function of the right ventricle with a simple linear measurement

    ST-Segment Elevation in a Patient With Nausea, Vomiting, and Intracerebral Hemorrhage

    Get PDF
    A 60-year-old man who presented with nausea, vomiting, and intracerebral hemorrhage developed inferior ST-segment elevation and angina. Coronary angiography showed no coronary obstruction. The patient was found to have a small bowel obstruction causing superior translocation of the heart. Relief of obstruction caused immediate resolution of electrocardiographic changes and symptoms. (Level of Difficulty: Beginner.

    On-orbit Metrology and Calibration Requirements for Space Station Activities Definition Study

    Get PDF
    The Space Station is the focal point for the commercial development of space. The long term routine operation of the Space Station and the conduct of future commercial activities suggests the need for in-space metrology capabilities analogous when possible to those on-Earth. The ability to perform periodic calibrations and measurements with proper traceability is imperative for the routine operation of the Space Station. An initial review, however, indicated a paucity of data related to metrology and calibration requirements for in-space operations. This condition probably exists because of the highly developmental aspect of space activities to date, their short duration, and nonroutine nature. The on-orbit metrology and calibration needs of the Space Station were examined and assessed. In order to achieve this goal, the following tasks were performed: an up-to-date literature review; identification of on-orbit calibration techniques; identification of sensor calibration requirements; identification of calibration equipment requirements; definition of traceability requirements; preparation of technology development plans; and preparation of the final report. Significant information and major highlights pertaining to each task is presented. In addition, some general (generic) conclusions/observations and recommendations that are pertinent to the overall in-space metrology and calibration activities are presented

    Influence of Smartphones and Software on Acoustic Voice Measures.

    Get PDF
    This study assessed the within-subject variability of voice measures captured using different recording devices (i.e., smartphones and head mounted microphone) and software programs (i.e., Analysis of Dysphonia in Speech and Voice (ADSV), Multi-dimensional Voice Program (MDVP), and Praat).  Correlations between the software programs that calculated the voice measures were also analyzed.  Results demonstrated no significant within-subject variability across devices and software and that some of the measures were highly correlated across software programs.  The study suggests that certain smartphones may be appropriate to record daily voice measures representing the effects of vocal loading within individuals.  In addition, even though different algorithms are used to compute voice measures across software programs, some of the programs and measures share a similar relationship.

    Prognostic value of echocardiography with particular reference to patients with valvular heart disease

    Get PDF
    Echocardiography is comparatively inexpensive relative to other modern cardiovascular imaging tools. It is widely available, even in poor countries, and provides a comprehensive evaluation of cardiac structure and function. It is an ideal tool for the evaluation of patients with valvular heart disease and provides important prognostic information. This review of recent literature highlights reports on outcomes data and provides a clinically valuable summary in table format

    Renal peroxiredoxin 6 interacts with anion exchanger 1 and plays a novel role in pH homeostasis.

    Get PDF
    Peroxiredoxin 6 (PRDX6) is one of the six members of the PRDX family, which have peroxidase and antioxidant activity. PRDX6 is unique, containing only one conserved cysteine residue (C47) rather than the two found in other PRDXs. A yeast two-hybrid screen found PRDX6 to be a potential binding partner of the C-terminal tail of anion exchanger 1 (AE1), a Cl(-)/HCO(3)(-) exchanger basolaterally expressed in renal α-intercalated cells. PRDX6 immunostaining in human kidney was both cytoplasmic and peripheral and colocalized with AE1. Analysis of native protein showed that it was largely monomeric, whereas expressed tagged protein was more dimeric. Two methionine oxidation sites were identified. In vitro and ex vivo pull-downs and immunoprecipitation assays confirmed interaction with AE1, but mutation of the conserved cysteine resulted in loss of interaction. Prdx6 knockout mice had a baseline acidosis with a major respiratory component and greater AE1 expression than wild-type animals. After an oral acid challenge, PRDX6 expression increased in wild-type mice, with preservation of AE1. However, AE1 expression was significantly decreased in knockout animals. Kidneys from acidified mice showed widespread proximal tubular vacuolation in wild-type but not knockout animals. Knockdown of PRDX6 by siRNA in mammalian cells reduced both total and cell membrane AE1 levels. Thus, PRDX6-AE1 interaction contributes to the maintenance of AE1 during cellular stress such as during metabolic acidosis.Human kidney sections were prepared by Suzy Haward, Addenbrooke's Human Research Tissue Bank, which is supported by the Cambridge Biomedical Research Centre. We thank Dr. Aron Fisher (Institute for Environmental Science, University of Pennsylvania) for the kind gift of Prdx6−/− mice and reagents, Carsten Wagner (Zurich) for antisera, Jane Clarke (University of Cambridge) for modified pRSET-A vector, and Kamburapola Jayawardena for mass spectrometry (CIMR). This work was funded by the Wellcome Trust (award 088489/Z/09/Z to FEKF and Strategic award 100140/Z/12/Z to the Cambridge Institute for Medical Research), and the Jack Kent Cooke Foundation (scholarship to SLS).This is the author accepted manuscript. The final version is available from Nature Publishing Group via http://dx.doi.org/10.1038/ki.2015.27
    • …
    corecore