29 research outputs found

    Plasma neutrophil gelatinase associated lipocalin (NGAL) is associated with kidney function in uraemic patients before and after kidney transplantation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Neutrophil gelatinase associated lipocalin (NGAL) is a biomarker of kidney injury. We examined plasma levels of NGAL in a cohort of 57 kidney allograft recipients (Tx group, 39 ± 13 years), a uraemic group of 40 patients remaining on the waiting list (47 ± 11 years) and a control group of 14 healthy subjects matched for age, sex and body mass index (BMI). The kidney graft recipients were studied at baseline before transplantation and 3 and 12 months after transplantation and the uraemic group at baseline and after 12 months.</p> <p>Methods</p> <p>NGAL was measured using a validated in-house Time-Resolved Immuno-flourometric assay (TRIFMA). Repeated measurements differed by < 10% and mean values were used for statistical analyses. Spearman rank order correlation analysis and the Kruskal-Wallis non-parametric test were used to evaluate the association of NGAL concentrations with clinical parameters.</p> <p>Results</p> <p>Plasma NGAL levels before transplantation in the Tx and uraemic groups were significantly higher than in the healthy controls (1,251 μg/L, 1,478 μg/L vs. 163 μg/L, p < 0.0001). In the Tx group NGAL concentrations were associated with serum creatinine (R = 0.51, p < 0.0001), duration of end-stage renal failure (R = 0.41, p = 0.002) and leukocyte count (R = 0.29, p < 0.026). At 3 and 12 months plasma NGAL concentrations declined to 223 μg/L and 243 μg/L, respectively and were associated with homocysteine (R = 0.39, p = 0.0051 and R = 0.47, p = 0.0007).</p> <p>Conclusions</p> <p>Plasma NGAL is a novel marker of kidney function, which correlates to duration of end-stage renal failure (ESRD) and serum creatinine in uraemic patients awaiting kidney transplantation. Plasma NGAL is associated with homocysteine in transplanted patients. The prognostic value of these findings requires further studies.</p

    Lanthanide-based time-resolved luminescence immunoassays

    Get PDF
    The sensitive and specific detection of analytes such as proteins in biological samples is critical for a variety of applications, for example disease diagnosis. In immunoassays a signal in response to the concentration of analyte present is generated by use of antibodies labeled with radioisotopes, luminophores, or enzymes. All immunoassays suffer to some extent from the problem of the background signal observed in the absence of analyte, which limits the sensitivity and dynamic range that can be achieved. This is especially the case for homogeneous immunoassays and surface measurements on tissue sections and membranes, which typically have a high background because of sample autofluorescence. One way of minimizing background in immunoassays involves the use of lanthanide chelate labels. Luminescent lanthanide complexes have exceedingly long-lived luminescence in comparison with conventional fluorophores, enabling the short-lived background interferences to be removed via time-gated acquisition and delivering greater assay sensitivity and a broader dynamic range. This review highlights the potential of using lanthanide luminescence to design sensitive and specific immunoassays. Techniques for labeling biomolecules with lanthanide chelate tags are discussed, with aspects of chelate design. Microtitre plate-based heterogeneous and homogeneous assays are reviewed and compared in terms of sensitivity, dynamic range, and convenience. The great potential of surface-based time-resolved imaging techniques for biomolecules on gels, membranes, and tissue sections using lanthanide tracers in proteomics applications is also emphasized
    corecore