67,153 research outputs found
Biomass production and nitrogen dynamics in an integrated aquaculture/agriculture system
A combined aquaculture/agriculture system that brings together the three major components of a Controlled Ecological Life Support System (CELSS) - biomass production, biomass processing, and waste recycling - was developed to evaluate ecological processes and hardware requirements necessary to assess the feasibility of and define design criteria for integration into the Kennedy Space Center (KSC) Breadboard Project. The system consists of a 1 square meter plant growth area, a 500 liter fish culture tank, and computerized monitoring and control hardware. Nutrients in the hydrophonic solution were derived from fish metabolites and fish food leachate. In five months of continuous operation, 27.0 kg of lettuce tops, 39.9 kg of roots and biofilm, and 6.6 kg of fish (wet weights) were produced with 12.7 kg of fish food input. Based on dry weights, a biomass conversion index of 0.52 was achieved. A nitrogen budget was derived to determine partitioning of nitrogen within various compartments of the system. Accumulating nitrogen in the hypoponic solution indicated a need to enlarge the plant growth area, potentially increasing the biomass production and improving the biomass conversion index
The principle of equivalence and projective structure in space-times
This paper discusses the extent to which one can determine the space-time
metric from a knowledge of a certain subset of the (unparametrised) geodesics
of its Levi-Civita connection, that is, from the experimental evidence of the
equivalence principle. It is shown that, if the space-time concerned is known
to be vacuum, then the Levi-Civita connection is uniquely determined and its
associated metric is uniquely determined up to a choice of units of
measurement, by the specification of these geodesics. It is further
demonstrated that if two space-times share the same unparametrised geodesics
and only one is assumed vacuum then their Levi-Civita connections are again
equal (and so the other metric is also a vacuum metric) and the first result
above is recovered.Comment: 23 pages, submitted to Classical and Quantum Gravit
Test results of the STI GPS time transfer receiver
Global time transfer, or synchronization, between a user clock and USNO UTC time can be performed using the Global Positioning System (GPS), and commercially available time transfer receivers. This paper presents the test results of time transfer using the GPS system and a Stanford Telecommunications, Inc. (STI) Time Transfer System (TTS) Model 502. Tests at the GPS Master Control Site (MCS) in Vandenburg, California and at the United States Naval Observatory (USNO) in Washington, D.C. are described. An overview of GPS, and the STI TTS 502 is presented. A discussion of the time transfer process and test concepts is included
On the Theory of Killing Orbits in Space-Time
This paper gives a theoretical discussion of the orbits and isotropies which
arise in a space-time which admits a Lie algebra of Killing vector fields. The
submanifold structure of the orbits is explored together with their induced
Killing vector structure. A general decomposition of a space-time in terms of
the nature and dimension of its orbits is given and the concept of stability
and instability for orbits introduced. A general relation is shown linking the
dimensions of the Killing algebra, the orbits and the isotropies. The
well-behaved nature of "stable" orbits and the possible miss-behaviour of the
"unstable" ones is pointed out and, in particular, the fact that independent
Killing vector fields in space-time may not induce independent such vector
fields on unstable orbits. Several examples are presented to exhibit these
features. Finally, an appendix is given which revisits and attempts to clarify
the well-known theorem of Fubini on the dimension of Killing orbits.Comment: Latex, 19 pages, no figur
Investigation of plane-strain flaw growth in thick-walled tanks Final report, 26 Jun. 1964 - 26 Oct. 1965
Flaw growth rates and fracture toughness data for materials used in thick walled cylindrical tank
Carbon Dioxide Observational Platform System (CO-OPS), feasibility study
The Carbon Dioxide Observational Platform System (CO-OPS) is a near-space, geostationary, multi-user, unmanned microwave powered monitoring platform system. This systems engineering feasibility study addressed identified existing requirements such as: carbon dioxide observational data requirements, communications requirements, and eye-in-the-sky requirements of other groups like the Defense Department, the Forestry Service, and the Coast Guard. In addition, potential applications in: earth system science, space system sciences, and test and verification (satellite sensors and data management techniques) were considered. The eleven month effort is summarized. Past work and methods of gathering the required observational data were assessed and rough-order-of magnitude cost estimates have shown the CO-OPS system to be most cost effective (less than $30 million within a 10 year lifetime). It was also concluded that there are no technical, schedule, or obstacles that would prevent achieving the objectives of the total 5-year CO-OPS program
Flavor changing interactions mediated by scalars at the weak scale
The quark and lepton mass matrices possess approximate flavor symmetries.
Several results follow if the interactions of new scalars possess these
approximate symmetries. Present experimental bounds allow these exotic scalars
to have a weak scale mass. The Glashow-Weinberg criterion is rendered
unnecessary. Finally, rare leptonic B meson decays provide powerful probes of
these scalars, especially if they are leptoquarks.Comment: 13 pages, report LBL-3234
Aerodynamics of lift fan V/STOL aircraft
Aerodynamic characteristics of lift fan installation for direct lift V/STOL aircraf
Optical transfer cavity stabilization using current-modulated injection-locked diode lasers
It is demonstrated that RF current modulation of a frequency stabilized
injection-locked diode laser allows the stabilization of an optical cavity to
adjustable lengths, by variation of the RF frequency. This transfer cavity may
be used to stabilize another laser at an arbitrary wavelength, in the absence
of atomic or molecular transitions suitable for stabilization. Implementation
involves equipment and techniques commonly used in laser cooling and trapping
laboratories, and does not require electro- or acousto-optic modulators. With
this technique we stabilize a transfer cavity using a RF current-modulated
diode laser which is injection locked to a 780 nm reference diode laser. The
reference laser is stabilized using polarization spectroscopy in a Rb cell. A
Ti:sapphire ring laser at 960 nm is locked to this transfer cavity and may be
precisely scanned by varying the RF modulation frequency. We demonstrate the
suitability of this system for the excitation of laser cooled Rb atoms to
Rydberg states
- …