67,153 research outputs found

    Biomass production and nitrogen dynamics in an integrated aquaculture/agriculture system

    Get PDF
    A combined aquaculture/agriculture system that brings together the three major components of a Controlled Ecological Life Support System (CELSS) - biomass production, biomass processing, and waste recycling - was developed to evaluate ecological processes and hardware requirements necessary to assess the feasibility of and define design criteria for integration into the Kennedy Space Center (KSC) Breadboard Project. The system consists of a 1 square meter plant growth area, a 500 liter fish culture tank, and computerized monitoring and control hardware. Nutrients in the hydrophonic solution were derived from fish metabolites and fish food leachate. In five months of continuous operation, 27.0 kg of lettuce tops, 39.9 kg of roots and biofilm, and 6.6 kg of fish (wet weights) were produced with 12.7 kg of fish food input. Based on dry weights, a biomass conversion index of 0.52 was achieved. A nitrogen budget was derived to determine partitioning of nitrogen within various compartments of the system. Accumulating nitrogen in the hypoponic solution indicated a need to enlarge the plant growth area, potentially increasing the biomass production and improving the biomass conversion index

    The principle of equivalence and projective structure in space-times

    Get PDF
    This paper discusses the extent to which one can determine the space-time metric from a knowledge of a certain subset of the (unparametrised) geodesics of its Levi-Civita connection, that is, from the experimental evidence of the equivalence principle. It is shown that, if the space-time concerned is known to be vacuum, then the Levi-Civita connection is uniquely determined and its associated metric is uniquely determined up to a choice of units of measurement, by the specification of these geodesics. It is further demonstrated that if two space-times share the same unparametrised geodesics and only one is assumed vacuum then their Levi-Civita connections are again equal (and so the other metric is also a vacuum metric) and the first result above is recovered.Comment: 23 pages, submitted to Classical and Quantum Gravit

    Test results of the STI GPS time transfer receiver

    Get PDF
    Global time transfer, or synchronization, between a user clock and USNO UTC time can be performed using the Global Positioning System (GPS), and commercially available time transfer receivers. This paper presents the test results of time transfer using the GPS system and a Stanford Telecommunications, Inc. (STI) Time Transfer System (TTS) Model 502. Tests at the GPS Master Control Site (MCS) in Vandenburg, California and at the United States Naval Observatory (USNO) in Washington, D.C. are described. An overview of GPS, and the STI TTS 502 is presented. A discussion of the time transfer process and test concepts is included

    On the Theory of Killing Orbits in Space-Time

    Full text link
    This paper gives a theoretical discussion of the orbits and isotropies which arise in a space-time which admits a Lie algebra of Killing vector fields. The submanifold structure of the orbits is explored together with their induced Killing vector structure. A general decomposition of a space-time in terms of the nature and dimension of its orbits is given and the concept of stability and instability for orbits introduced. A general relation is shown linking the dimensions of the Killing algebra, the orbits and the isotropies. The well-behaved nature of "stable" orbits and the possible miss-behaviour of the "unstable" ones is pointed out and, in particular, the fact that independent Killing vector fields in space-time may not induce independent such vector fields on unstable orbits. Several examples are presented to exhibit these features. Finally, an appendix is given which revisits and attempts to clarify the well-known theorem of Fubini on the dimension of Killing orbits.Comment: Latex, 19 pages, no figur

    Investigation of plane-strain flaw growth in thick-walled tanks Final report, 26 Jun. 1964 - 26 Oct. 1965

    Get PDF
    Flaw growth rates and fracture toughness data for materials used in thick walled cylindrical tank

    Carbon Dioxide Observational Platform System (CO-OPS), feasibility study

    Get PDF
    The Carbon Dioxide Observational Platform System (CO-OPS) is a near-space, geostationary, multi-user, unmanned microwave powered monitoring platform system. This systems engineering feasibility study addressed identified existing requirements such as: carbon dioxide observational data requirements, communications requirements, and eye-in-the-sky requirements of other groups like the Defense Department, the Forestry Service, and the Coast Guard. In addition, potential applications in: earth system science, space system sciences, and test and verification (satellite sensors and data management techniques) were considered. The eleven month effort is summarized. Past work and methods of gathering the required observational data were assessed and rough-order-of magnitude cost estimates have shown the CO-OPS system to be most cost effective (less than $30 million within a 10 year lifetime). It was also concluded that there are no technical, schedule, or obstacles that would prevent achieving the objectives of the total 5-year CO-OPS program

    Flavor changing interactions mediated by scalars at the weak scale

    Full text link
    The quark and lepton mass matrices possess approximate flavor symmetries. Several results follow if the interactions of new scalars possess these approximate symmetries. Present experimental bounds allow these exotic scalars to have a weak scale mass. The Glashow-Weinberg criterion is rendered unnecessary. Finally, rare leptonic B meson decays provide powerful probes of these scalars, especially if they are leptoquarks.Comment: 13 pages, report LBL-3234

    Aerodynamics of lift fan V/STOL aircraft

    Get PDF
    Aerodynamic characteristics of lift fan installation for direct lift V/STOL aircraf

    Optical transfer cavity stabilization using current-modulated injection-locked diode lasers

    Get PDF
    It is demonstrated that RF current modulation of a frequency stabilized injection-locked diode laser allows the stabilization of an optical cavity to adjustable lengths, by variation of the RF frequency. This transfer cavity may be used to stabilize another laser at an arbitrary wavelength, in the absence of atomic or molecular transitions suitable for stabilization. Implementation involves equipment and techniques commonly used in laser cooling and trapping laboratories, and does not require electro- or acousto-optic modulators. With this technique we stabilize a transfer cavity using a RF current-modulated diode laser which is injection locked to a 780 nm reference diode laser. The reference laser is stabilized using polarization spectroscopy in a Rb cell. A Ti:sapphire ring laser at 960 nm is locked to this transfer cavity and may be precisely scanned by varying the RF modulation frequency. We demonstrate the suitability of this system for the excitation of laser cooled Rb atoms to Rydberg states
    corecore