60 research outputs found

    Narrow linewidth, single frequency semiconductor laser with a phase conjugate external cavity mirror

    Get PDF
    We measure the spectral characteristics of an external cavity semiconductor laser which uses a phase conjugate mirror for its external reflection. This device has significant advantages over the conventional external cavity system owing to the self-aligning nature of the phase conjugate mirror. The fiber delay line self-heterodyne technique is used to measure the fundamental linewidth for single mode operation of this device. It shows the linewidth to be at least as narrow as the instrumental resolution of 100 kHz

    Impact of mediastinal, liver and lung 123I-metaiodobenzylguanidine (123I-MIBG) washout on calculated 123I-MIBG myocardial washout

    Get PDF
    PURPOSE: In planar (123)I-metaiodobenzylguanidine ((123)I-MIBG) myocardial imaging mediastinum (M) activity is often used as a background correction in calculating "washout" (WO). However, the most likely sources for counts that might produce errors in estimating myocardial (Myo) activity are lung (Lu) and liver (Li), which typically have higher counts/pixel (cpp) than M. The present study investigated the relationship between changes in Lu, Li and Myo activity between early and late planar (123)I-MIBG images, with comparison to M as the best estimator of non-specific background activity. METHODS: Studies on 98 subjects with both early (e) and late (l) planar (123)I-MIBG images were analysed. There were 68 subjects with chronic heart failure (CHF), 14 with hypertension (HTN) but no known heart disease and 16 controls (C). For each image, regions of interest (ROIs) were drawn: an irregular whole Myo, Lu, upper M and Li. For each ROI, WO was calculated as [(cpp(e)-cpp(l:decay corrected))/cpp(e)]x100%. RESULTS: Multivariable forward stepwise regression analysis showed that overall a significant proportion of the variation in Myo WO could be explained by a model containing M WO and Lu WO (37%, p < 0.001). Only in controls was M WO the sole variable explaining a significant proportion of the variation in Myo WO (27%, p = 0.023). CONCLUSION: Although increased Myo WO in CHF subjects reflects disease severity, part of the count differences measured on planar (123)I-MIBG myocardial images likely reflects changes in the adjacent and surrounding Lu tissue. The results for the controls suggest that this is the only group where a mediastinum correction alone may be appropriate for cardiac WO calculation

    Novel iodinated tracers, MIBG and BMIPP, for nuclear cardiology

    Get PDF
    With the rapid growth of molecular biology, in vivo imaging of such molecular process (i.e., molecular imaging) has been well developed. The molecular imaging has been focused on justifying advanced treatments and for assessing the treatment effects. Most of molecular imaging has been developed using PET camera and suitable PET radiopharmaceuticals. However, this technique cannot be widely available and we need alternative approach. 123I-labeled compounds have been also suitable for molecular imaging using single-photon computed tomography (SPECT) 123I-labeled meta-iodobenzylguanidine (MIBG) has been used for assessing severity of heart failure and prognosis. In addition, it has a potential role to predict fatal arrhythmia, particularly for those who had and are planned to receive implantable cardioverter-defibrillator treatment. 123I-beta-methyl-iodophenylpentadecanoic acid (BMIPP) plays an important role for identifying ischemia at rest, based on the unique capability to represent persistent metabolic alteration after recovery of ischemia, so called ischemic memory. Since BMIPP abnormalities may represent severe ischemia or jeopardized myocardium, it may permit risk analysis in CAD patients, particularly for those with chronic kidney disease and/or hemodialysis patients. This review will discuss about recent development of these important iodinated compounds

    Variations in 123I-metaiodobenzylguanidine (MIBG) late heart mediastinal ratios in chronic heart failure: a need for standardisation and validation

    Get PDF
    BACKGROUND: There is lack of validation and standardisation of acquisition parameters for myocardial (123)I-metaiodobenzylguanidine (MIBG). This lack of standardisation hampers large scale implementation of (123)I-MIBG parameters in the evaluation of patients with chronic heart failure (CHF). METHODS: In a retrospective multi-centre study (123)I-MIBG planar scintigrams obtained on 290 CHF patients (82% male; 58% dilated cardiomyopathy; New York Heart Association [NYHA classification] > I) were reanalysed to determine the late heart-to-mediastinum ratio (H/M). RESULTS: There was a large variation in acquisition parameters. Multivariate forward stepwise regression showed that a significant proportion (31%, p < 0.001) of the variation in late H/M could be explained by a model containing patient-related variables and acquisition parameters. Left ventricular ejection fraction (p < 0.001), type of collimation (p < 0.001), acquisition duration (p = 0.001), NYHA class (p = 0.028) and age (p = 0.034) were independent predictors of late H/M. CONCLUSIONS: Acquisitions parameters are independent contributors to the variation of semi-quantitative measurements of cardiac (123)I-MIBG uptake. Improved standardisation of cardiac (123)I-MIBG imaging parameters would contribute to increased clinical applicability for this procedur
    • ā€¦
    corecore