27 research outputs found

    Quark condensates in the chiral bag with the NJL interaction

    Get PDF
    We discuss the quark condensate of the vacuum inside the baryon. We analyze the 1+1 dimensional chiral bag in analogy with the realistic 3+1 dimensional one. The Nambu--Jona-Lasinio (NJL) type interaction is used to investigate the quark condensate in the chiral bag. Considering the strong meson-quark coupling, we solve the mean field solution to the scalar and pseudoscalar channels by including the chiral Casimir effects. The self-consistent equation allows a finite value of the quark condensate and hence a finite dynamical quark mass inside the bag. It is shown that an approximate Cheshire Cat picture holds for massive quarks

    Asian-Specific total knee system: 5-14 year follow-up study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Knee size and body size differ in Asians compared with Caucasians. Nevertheless, many total knee arthroplasty (TKA) prostheses used worldwide are made for Western Caucasian subjects. As a result, an Asian's knee might not fit these prostheses. We studied the Flexible Nichidai Knee (FNK) system, a new model of TKA for Asian patients. The purpose of this report is to investigate the outcomes of this prosthesis retrospectively.</p> <p>Methods</p> <p>We investigated 1055 primary TKAs in 595 patients who underwent FNK for osteoarthritis (OA) in Japan and were followed for > 5 years. The knee score and function score were used for clinical evaluation. We examined the range of motion (ROM) preoperatively and at final follow-up and radiographic assessments. In addition, postoperative complications were investigated. A survivorship analysis was also conducted using two endpoints: revision for any reason and aseptic failure.</p> <p>Results</p> <p>890 knees in 502 patients were available for study (follow-up rate of 96.0%). The mean follow-up term was 8.3 years (range, 5.0-14.1 years). The knee and function score significantly improved from 41.3 to 90.3 and from 39.1 to 76.2 points, respectively (p < 0.001). The mean ROM in FNK posterior cruciate retaining (CR) type and FNK posterior-stabilized (PS) type ameliorated significantly from 107.8° and 95.6° to 110.7° and 110.4°, respectively (p < 0.01). Ten knees underwent revision surgery (infection in 3 cases, instability in 2, loosening in 2, and non-union of femoral supracondylar fracture, severe pain, and recurrent hemarthrosis in 1 each). The survivorship rate was 99.4% (95% CI, 99.0-99.8) at 5 years (n = 952 patients at risk) and 96.2% (95% CI, 91.9-100) at 12.5 years (n = 49 patients at risk).</p> <p>Conclusion</p> <p>The FNK prosthesis for Asians achieved excellent mid- to long-term survivorship and clinical results.</p

    Penetration of an Inferior Vena Cava Filter into the Aorta

    No full text
    corecore