37 research outputs found

    Embolization using warmed glue via the triaxial microballoon occlusion system for various vascular disorders

    Get PDF
    PURPOSE:We aimed to illustrate the benefits of using warmed glue for viscosity reduction via the triaxial microballoon system for the treatment of various vascular disorders.METHODS:Seven patients who underwent 10 treatment sessions for hemoptysis, type II endoleak, post-pancreatic surgical bleeding, spontaneous retroperitoneal bleeding, or ovarian tumor bleeding were evaluated based on technical and clinical outcomes. In the procedure, the triaxial system, consisting of a 4.5-Fr guiding catheter, a 2.8-Fr microballoon catheter, and a 1.9-Fr no-taper microcatheter, was advanced into the target lesion. Glue (33% n-butyl cyanoacrylate mixed with Lipiodol) warmed to 40°C was injected under balloon occlusion.RESULTS:The common hepatic, right bronchial, intercostals, internal mammary, costocervical, lateral thoracic, superior thoracic, thoracoacromial, inferior thyroid, iliolumbar, lumbar, internal pudendal arteries, and branch of the inferior mesenteric artery were successfully embolized; 100% technical success and 100% clinical success were obtained after each session.CONCLUSION:Our modified balloon-occluded glue embolization may lead to better handling with more distal glue penetration capability

    Reproducibility of Standardized Uptake Values Including Volume Metrics Between TOF-PET-MR and TOF-PET-CT.

    Get PDF
    Purpose To investigate the reproducibility of tracer uptake measurements, including volume metrics, such as metabolic tumor volume (MTV) and tumor lesion glycolysis (TLG) obtained by TOF-PET-CT and TOF-PET-MR. Materials and Methods Eighty consecutive patients with different oncologic diagnoses underwent TOF-PET-CT (Discovery 690; GE Healthcare) and TOF-PET-MR (SIGNA PET-MR; GE Healthcare) on the same day with single dose-18F-FDG injection. The scan order, PET-CT following or followed by PET-MR, was randomly assigned. A spherical volume of interest (VOI) of 30 mm was placed on the liver in accordance with the PERCIST criteria. For liver, the maximum and mean standard uptake value for body weight (SUV) and lean body mass (SUL) were obtained. For tumor delineation, VOI with a threshold of 40 and 50% of SUVmax was used (VOI40 and VOI50). The SUVmax, SUVmean, SUVpeak, MTV and TLG were calculated. The measurements were compared between the two scanners. Results In total, 80 tumor lesions from 35 patients were evaluated. There was no statistical difference observed in liver regions, whereas in tumor lesions, SUVmax, SUV mean, and SUVpeak of PET-MR were significantly underestimated (p < 0.001) in both VOI40 and VOI50. Among volume metrics, there was no statistical difference observed except TLG on VOI50 (p = 0.03). Correlation between PET-CT and PET-MR of each metrics were calculated. There was a moderate correlation of the liver SUV and SUL metrics (r = 0.63-0.78). In tumor lesions, SUVmax and SUVmean had a stronger correlation with underestimation in PET-MR on VOI 40 (SUVmax and SUVmean; r = 0.92 and 0.91 with slope = 0.71 and 0.72, respectively). In the evaluation of MTV and TLG, the stronger correlations were observed both on VOI40 (MTV and TLG; r = 0.75 and 0.92) and VOI50 (MTV and TLG; r = 0.88 and 0.95) between PET-CT and PET-MR. Conclusion PET metrics on TOF-PET-MR showed a good correlation with that of TOF-PET-CT. SUVmax and SUVpeak of tumor lesions were underestimated by 16% on PET-MRI. MTV with % threshold can be regarded as identical volumetric markers for both TOF-PET-CT and TOF-PET-MR

    Management of Gastric Varices Unsuccessfully Treated by Balloon-Occluded Retrograde Transvenous Obliteration: Long-Term Follow-Up and Outcomes

    Get PDF
    Our aim was to evaluate the long-term efficacy and safety of percutaneous transhepatic obliteration (PTO) alone and combined with balloon-occluded retrograde transvenous obliteration (BRTO) for gastroesophageal varices refractory to BRTO alone. Between July 1999 and December 2010, 13 patients with gastroesophageal varices refractory to BRTO were treated with PTO (n = 6) or a combination of PTO and BRTO (n = 7). We retrospectively investigated the rates of survival, recurrence, or worsening of the varices; hepatic function before and after the procedure; and complications. The procedure achieved complete obliteration or significant reduction of the varices in all 13 patients without major complications. During follow-up, the varices had recurred in 2 patients, of which one had hepatocellular carcinoma, and the other died suddenly from variceal rebleeding 7 years after PTO. The remaining 11 patients did not experience worsening of the varices and showed significant improvements in the serum ammonia levels and prothrombin time. The mean follow-up period was 90 months, and the cumulative survival rate at 1, 3, and 5 years was 92.9%, 85.7%, and 85.7%, respectively. Both PTO and combined PTO and BRTO seem as safe and effective procedures for the treatment of gastroesophageal varices refractory to BRTO alone

    In vivo evaluation of a monodisperse solid-in-oil-in-water miriplatin/ lipiodol emulsion in transcatheter arterial chemoembolization using a rabbit VX2 tumor model.

    No full text
    Transcatheter arterial chemoembolization (TACE) is a standard treatment for unresectable hepatocellular carcinoma; however, it does not always result in tumor control. Nevertheless, treatment outcome can be improved with monodisperse emulsions of anticancer agents. In this study, the distribution of a monodisperse miriplatin-Lipiodol emulsion in the tumor and its safety were evaluated in ten Japanese white rabbits. VX2 tumor was implanted into the left liver lobe. The animals were divided into control and experimental groups (of five animals each) and respectively administered a conventional miriplatin suspension or the emulsion via the left hepatic artery. Computed tomography (CT) was performed before, immediately after, and two days following TACE. All rabbits were sacrificed two days after the procedure. Each tumor was removed and cut in half for assessment of iodine concentration in one half by mass spectroscopy and evaluation of Lipiodol accumulation and adverse events in the other half. Mean Hounsfield unit (HU) values were measured using plain CT images taken before and after TACE. Iodine concentration was higher in the experimental group [1100 (750-1500) ppm, median (range)] than in the control group [840 (660-1800) ppm], although statistically not significant. Additionally, the HU value for the experimental group was higher than that for the control group immediately after [199.6 (134.0-301.7) vs. 165.3 (131.4-280.5)] and two days after [114.2 (56.1-229.8) vs. 58.3 (42.9-132.5)] TACE, although statistically not significant. Cholecystitis was observed in one rabbit in the control group. Ischemic bile duct injury was not observed in any group. The results show that Lipiodol accumulation and retention in VX2 tumor can possibly be improved with a monodisperse emulsion; however, it should be verified with a larger study. Moreover, no significant adverse events are associated with the use of the emulsion

    Diagnostic performance of hybrid cardiac SPECT/CT imaging for patients with takotsubo cardiomyopathy

    No full text
    Abstract Background The diagnostic performance of SPECT-only imaging for takotsubo cardiomyopathy (TC) is limited due to the lack of coronary artery distribution information. The aim of this study was to evaluate the diagnostic performance of hybrid cardiac SPECT/CT for patients with TC or acute coronary syndrome (ACS). Methods Twenty-two patients with apical ballooning left ventricular (LV) dysfunction who underwent cardiac perfusion SPECT using 99mTc-methoxy-isobutyl-isonitrile (MIBI), cardiac fatty-acid metabolism SPECT using 123I–beta-methyl-P-iodophenyl-pentadecanoic acid (BMIPP), cardiac CT, and hybrid cardiac SPECT/CT imaging were analyzed. On the SPECT images, MIBI and BMIPP defects were quantified using a 17-segment model with a 5-point grading system and a summed MIBI defect score (SMDS), summed BMIPP defect score (SBDS), and summed mismatch score (SMS) were calculated. Furthermore, apical and non-apical MDS, BDS, and mismatch scores (A- and NA-MDS, A- and NA-BDS, and A- and NA-MS) were calculated. These quantitative scores were compared between the TC (n = 11) and ACS (n = 11) groups, and the diagnostic performances of SPECT-only imaging and hybrid SPECT/CT imaging were compared. For all patients, the diagnoses of both SPECT-only and SPECT/CT imaging were categorized as TC: SPECT accumulation defects around apical LV wall deviated from the actual coronary artery territories, equivocal: unclear relationship of accumulation defects and the coronary artery territories, or non-TC: accumulation defects coincided with the coronary artery territories. Results SMDS and SBDS did not significantly differ between TC and ACS patients [SMDS: 5 (3–7) vs. 8 (4–16), p = 0.216; SBDS: 10 (8–12) vs. 18 (9–24), p = 0.354]. While A-MDS and A-BDS did not significantly differ between patients with TC and ACS (p = 0.567 and p = 0.386, respectively), NA-MDS and NA-BDS were significantly lower for patients with TC (p = 0.022 and p = 0.022, respectively). Compared with SPECT-only imaging (sensitivity: 30% and specificity: 81%), hybrid SPECT/CT imaging showed a higher accuracy (sensitivity: 90% and specificity: 100%) for the diagnosis of TC. Conclusions Hybrid cardiac SPECT/CT imaging may have superior diagnostic performance compared with SPECT-only imaging for patients with TC

    Coil embolization using microballoon assistance combined with the double-catheter technique for a large superior mesenteric arterial pseudoaneurysm and fistula secondary to acute pancreatitis

    No full text
    Pseudoaneurysm of the superior mesenteric artery (SMA) is rare and associated with the risk of massive fatal hemorrhage and acute mesenteric ischemia. We describe a 43-year-old man with acute pancreatitis who presented with an SMA pseudoaneurysm measuring 13 × 12 cm in diameter. The pseudoaneurysm originated between the first and second jejunal arteries and drained into the mesenteric vein. The SMA trunk between the first and second jejunal arteries was embolized with detachable coils using microballoon assistance. After coil placement, arteriography showed the collateral circulation and no perfusion delay of the distal SMA. This technique was useful for isolation of the SMA pseudoaneurysm
    corecore