451 research outputs found

    Nerve tolerance to high-dose-rate brachytherapy in patients with soft tissue sarcoma: a retrospective study

    Get PDF
    BACKGROUND: Brachytherapy, interstitial tumor bed irradiation, following conservative surgery has been shown to provide excellent local control and limb preservation in patients with soft tissue sarcomas (STS), whereas little is known about the tolerance of peripheral nerves to brachytherapy. In particular, nerve tolerance to high-dose-rate (HDR) brachytherapy has never been properly evaluated. In this study, we examined the efficacy and radiation neurotoxicity of HDR brachytherapy in patients with STS in contact with neurovascular structures. METHODS: Between 1995 and 2000, seven patients with STS involving the neurovascular bundle were treated in our institute with limb-preserving surgery, followed by fractionated HDR brachytherapy. Pathological examination demonstrated that 6 patients had high-grade lesions with five cases of negative margins and one case with positive margins, and one patient had a low-grade lesion with a negative margin. Afterloading catheters placed within the tumor bed directly upon the preserved neurovascular structures were postoperatively loaded with Iridium-192 with a total dose of 50 Gy in 6 patients. One patient received 30 Gy of HDR brachytherapy combined with 20 Gy of adjuvant external beam radiation. RESULTS: With a median follow-up of 4 years, the 5-year actuarial overall survival, disease-free survival, and local control rates were 83.3, 68.6, and 83.3%, respectively. None of the 7 patients developed HDR brachytherapy-induced peripheral neuropathy. Of 5 survivors, 3 evaluable patients had values of motor nerve conduction velocity of the preserved peripheral nerve in the normal range. CONCLUSION: In this study, there were no practical and electrophysiological findings of neurotoxicity of HDR brachytherapy. Despite the small number of patients, our encouraging results are valuable for limb-preserving surgery of unmanageable STS involving critical neurovascular structures

    Quantum dynamics in strong fluctuating fields

    Full text link
    A large number of multifaceted quantum transport processes in molecular systems and physical nanosystems can be treated in terms of quantum relaxation processes which couple to one or several fluctuating environments. A thermal equilibrium environment can conveniently be modelled by a thermal bath of harmonic oscillators. An archetype situation provides a two-state dissipative quantum dynamics, commonly known under the label of a spin-boson dynamics. An interesting and nontrivial physical situation emerges, however, when the quantum dynamics evolves far away from thermal equilibrium. This occurs, for example, when a charge transferring medium possesses nonequilibrium degrees of freedom, or when a strong time-dependent control field is applied externally. Accordingly, certain parameters of underlying quantum subsystem acquire stochastic character. Herein, we review the general theoretical framework which is based on the method of projector operators, yielding the quantum master equations for systems that are exposed to strong external fields. This allows one to investigate on a common basis the influence of nonequilibrium fluctuations and periodic electrical fields on quantum transport processes. Most importantly, such strong fluctuating fields induce a whole variety of nonlinear and nonequilibrium phenomena. A characteristic feature of such dynamics is the absence of thermal (quantum) detailed balance.Comment: review article, Advances in Physics (2005), in pres

    Influence of electrolyte co-additives on the performance of dye-sensitized solar cells

    Get PDF
    The presence of specific chemical additives in the redox electrolyte results in an efficient increase of the photovoltaic performance of dye-sensitized solar cells (DSCs). The most effective additives are 4-tert-butylpyridine (TBP), N-methylbenzimidazole (NMBI) and guanidinium thiocyanate (GuNCS) that are adsorbed onto the photoelectrode/electrolyte interface, thus shifting the semiconductor's conduction band edge and preventing recombination with triiodides. In a comparative work, we investigated in detail the action of TBP and NMBI additives in ionic liquid-based redox electrolytes with varying iodine concentrations, in order to extract the optimum additive/I2 ratio for each system. Different optimum additive/I2 ratios were determined for TBP and NMBI, despite the fact that both generally work in a similar way. Further addition of GuNCS in the optimized electrolytic media causes significant synergistic effects, the action of GuNCS being strongly influenced by the nature of the corresponding co-additive. Under the best operation conditions, power conversion efficiencies as high as 8% were obtained

    The effect of an external magnetic force on cell adhesion and proliferation of magnetically labeled mesenchymal stem cells

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>As the strategy for tissue regeneration using mesenchymal stem cells (MSCs) for transplantation, it is necessary that MSCs be accumulated and kept in the target area. To accumulate MSCs effectively, we developed a novel technique for a magnetic targeting system with magnetically labeled MSCs and an external magnetic force. In this study, we examined the effect of an external magnetic force on magnetically labeled MSCs in terms of cell adhesion and proliferation.</p> <p>Methods</p> <p>Magnetically labeled MSCs were plated at the bottom of an insert under the influence of an external magnetic force for 1 hour. Then the inserts were turned upside down for between 1 and 24 hours, and the number of MSCs which had fallen from the membrane was counted. The gene expression of MSCs affected magnetic force was analyzed with microarray. In the control group, the same procedure was done without the external magnetic force.</p> <p>Results</p> <p>At 1 hour after the inserts were turned upside down, the average number of fallen MSCs in the magnetic group was significantly smaller than that in the control group, indicating enhanced cell adhesion. At 24 hours, the average number of fallen MSCs in the magnetic group was also significantly smaller than that in control group. In the magnetic group, integrin alpha2, alpha6, beta3 BP, intercellular adhesion molecule-2 (ICAM-2), platelet/endothelial cell adhesion molecule-1 (PECAM-1) were upregulated. At 1, 2 and 3 weeks after incubation, there was no statistical significant difference in the numbers of MSCs in the magnetic group and control group.</p> <p>Conclusions</p> <p>The results indicate that an external magnetic force for 1 hour enhances cell adhesion of MSCs. Moreover, there is no difference in cell proliferation after using an external magnetic force on magnetically labeled MSCs.</p

    Promoting Effect of Layered Titanium Phosphate on the Electrochemical and Photovoltaic Performance of Dye-Sensitized Solar Cells

    Get PDF
    We reported a composite electrolyte prepared by incorporating layered α-titanium phosphate (α-TiP) into an iodide-based electrolyte using 1-ethyl-3-methylimidazolium tetrafluoroborate(EmimBF4) ionic liquid as solvent. The obtained composite electrolyte exhibited excellent electrochemical and photovoltaic properties compared to pure ionic liquid electrolyte. Both the diffusion coefficient of triiodide (I3−) in the electrolyte and the charge-transfer reaction at the electrode/electrolyte interface were improved markedly. The mechanism for the enhanced electrochemical properties of the composite electrolyte was discussed. The highest conversion efficiency of dye-sensitized solar cell (DSSC) was obtained for the composite electrolyte containing 1wt% α-TiP, with an improvement of 58% in the conversion efficiency than the blank one, which offered a broad prospect for the fabrication of stable DSSCs with a high conversion efficiency

    Between-day reliability of electromechanical delay of selected neck muscles during performance of maximal isometric efforts

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The purpose of this study was to assess the between-day reliability of the electromechanical delay (EMD) of selected neck muscles during the performance of maximal isometric contractions in five different directions.</p> <p>Methods</p> <p>Twenty-one physically active males participated in two testing sessions separated by seven to eight days. Using a custom-made fixed frame dynamometer, cervical force and surface electromyography (EMG) were recorded bilaterally from the splenius capitis, upper trapezius and sternocleidomastoid muscles during the performance of efforts in extension, flexion, left and right lateral bending, and protraction. The EMD was extracted using the Teager-Kaiser Energy Operator. Reliability indices calculated for each muscle in each testing direction were: the difference in scores between the two testing sessions and corresponding 95% confidence intervals, the standard error of measurement (SEM) and intra-class correlation coefficients (ICC).</p> <p>Results</p> <p>EMD values showed no evidence of systematic difference between the two testing sessions across all muscles and testing directions. The SEM for extension, flexion and lateral bending efforts ranged between 2.5 ms to 4.8 ms, indicating a good level of measurement precision. For protraction, SEM values were higher and considered to be imprecise for research and clinical purposes. ICC values for all muscles across all testing directions ranged from 0.23 to 0.79.</p> <p>Conclusion</p> <p>EMD of selected neck muscles can be measured with sufficient precision for the assessment of neck muscle function in an athletic population in the majority of directions tested.</p

    Electron spin coherence exceeding seconds in high purity silicon

    Full text link
    Silicon is undoubtedly one of the most promising semiconductor materials for spin-based information processing devices. Its highly advanced fabrication technology facilitates the transition from individual devices to large-scale processors, and the availability of an isotopically-purified 28^{28}Si form with no magnetic nuclei overcomes what is a main source of spin decoherence in many other materials. Nevertheless, the coherence lifetimes of electron spins in the solid state have typically remained several orders of magnitude lower than what can be achieved in isolated high-vacuum systems such as trapped ions. Here we examine electron spin coherence of donors in very pure 28^{28}Si material, with a residual 29^{29}Si concentration of less than 50 ppm and donor densities of 10141510^{14-15} per cm3^3. We elucidate three separate mechanisms for spin decoherence, active at different temperatures, and extract a coherence lifetime T2T_2 up to 2 seconds. In this regime, we find the electron spin is sensitive to interactions with other donor electron spins separated by ~200 nm. We apply a magnetic field gradient in order to suppress such interactions and obtain an extrapolated electron spin T2T_2 of 10 seconds at 1.8 K. These coherence lifetimes are without peer in the solid state by several orders of magnitude and comparable with high-vacuum qubits, making electron spins of donors in silicon ideal components of a quantum computer, or quantum memories for systems such as superconducting qubits.Comment: 18 pages, 4 figures, supplementary informatio
    corecore