529 research outputs found

    DARTS-ASR: Differentiable Architecture Search for Multilingual Speech Recognition and Adaptation

    Full text link
    In previous works, only parameter weights of ASR models are optimized under fixed-topology architecture. However, the design of successful model architecture has always relied on human experience and intuition. Besides, many hyperparameters related to model architecture need to be manually tuned. Therefore in this paper, we propose an ASR approach with efficient gradient-based architecture search, DARTS-ASR. In order to examine the generalizability of DARTS-ASR, we apply our approach not only on many languages to perform monolingual ASR, but also on a multilingual ASR setting. Following previous works, we conducted experiments on a multilingual dataset, IARPA BABEL. The experiment results show that our approach outperformed the baseline fixed-topology architecture by 10.2% and 10.0% relative reduction on character error rates under monolingual and multilingual ASR settings respectively. Furthermore, we perform some analysis on the searched architectures by DARTS-ASR.Comment: Accepted at INTERSPEECH 202

    Prevalence of latent tuberculosis infection in BCG-vaccinated healthcare workers by using an interferon-gamma release assay and the tuberculin skin test in an intermediate tuberculosis burden country

    Get PDF
    BackgroundThe risk of healthcare workers (HCWs) acquiring tuberculosis (TB) infection is high. We determined the prevalence of latent TB infection (LTBI) in HCWs with a high Bacille Calmette-Guérin (BCG) vaccine coverage in an intermediate TB burden country by using an interferon-gamma release assay [QuantiFERON-TB Gold (QFT-G)] and by using the tuberculin skin test (TST). Risk factors associated with a positive test were determined.MethodsThis prospective cross-sectional study enrolled HCWs from a medical center in Taiwan. Participants were grouped into workers without exposure (Group 1) and workers who self-reported a history of TB exposure (Group 2). All participants completed a questionnaire to collect demographic information and risk factors for acquiring TB. The QFT-G test and the TST were administered and risk factors for a positive test were analyzed.ResultsWe recruited 193 HCWs [149 (77.2%) female workers] with a mean age of 35.6 years. All were BCG-vaccinated. The prevalence of LTBI was 88.8% (based on the TST) and 14.5% (based on the QFT-G test). There was no difference between HCWs with and without known exposure to TB. Agreement between the tests was poor (i.e., the kappa value was less than 0.05). Multivariable logistic regression showed that only the QFT-G test was associated with age (35 years or greater) (adjusted OR, 2.53; p = 0.03).ConclusionBy using the QFT-G test or TST, this study found a similar prevalence of LTBI in HCWs with and without known exposure to TB. This suggests that in intermediate TB burden countries exposure to TB may occur within the hospital and within the community. Compared to the TST, the QFT-G test was correlated better with age, which is a known risk factor for latent TB infection

    Delayed Airway Obstruction after Internal Jugular Venous Catheterization in a Patient with Anticoagulant Therapy

    Get PDF
    Delayed onset of neck hematoma following central venous catheterization without arterial puncture is uncommon. Herein, we present a patient who developed a delayed neck hematoma after repeated attempts at right internal jugular venous puncture and subsequent enoxaparin administration. Progressive airway obstruction occurred on the third day after surgery. Ultrasound examination revealed diffuse hematoma of the right neck, and fibreoptic examination of the airway revealed pharyngeal edema. After emergent surgical removal of the hematoma, the patient was extubated uneventfully

    Attenuation of Guided Wave Propagation by the Insulation Pipe

    Get PDF
    Pipeline systems are widely used in gas, refinery, chemical and petro-chemical industries, which usually carry high pressure, high temperature or even highly corrosive fluids. Cracks and corrosion are often found at the outer or inner surface of pipeline and can lead to a serious thinning of wall thickness. Leaks or sudden failures of pipes can cause injuries, fatalities and environmental damage. Ultrasonic nondestructive techniques are available for the detection of wall loss associated with defects in the pipe. Unfortunately, a high proportion in pipelines of these industrial are insulated, so that even external corrosion cannot readily be detected by the conventional ultrasonic testing (single position measurement) without the removal of the insulation, which in most case is time-consuming and cost expensive. Especially in typically industrial plants, there are hundreds of kilometers of pipelines can be in operation. Making inspection of full pipelines is virtually impossible in industrial plants. There is therefore a quick reliable method for the detection of corrosion under insulation (CUI). This technique, called guided wave, employs a pulseecho system applied at a single location of a pipe where only a small section of insulation need to be removed, using waves propagation along the pipe wall. The changes in the response signal indicate the presence of an impedance change in the pipe. The shape and axial location of defects and features in the pipe are also determined by reflected signals and their arrival times. Propagation distance of many tens of meters can readily be obtained in steel pipes [1-6]. Since these guided waves are cylindrical Lamb waves along the pipe, no lateral spreading can occur and the propagation is essentially one-dimensional. In a uniform pipe, their amplitude with propagation distance is therefore only reduced by the material attenuation of the steel [7]
    corecore