5 research outputs found

    Preoperative imaging in primary hyperparathyroidism patients using 4DCT subtraction maps, a report of three cases

    Get PDF
    Four-dimensional computed tomography (4DCT) is one of the preoperative imaging modalities that can be used to localize a parathyroid adenoma in primary hyperparathyroidism patients however, sensitivity differs in literature and could be improved especially for multiglandular hyperplasia or double adenomas. The most robust feature on the 4DCT for the differentiation between parathyroid adenoma and thyroid gland tissue is arterial enhancement. To make this better visible, we have developed a subtraction map that shows arterial enhancement as a color scale to increase sensitivity for 4DCT. In this report of 3 cases, we present the usefulness of this subtraction map in a 54-year-old male, a 57-year-old female and a 51-year-old male. Subtraction maps may increase sensitivity for 4DCT, especially for multiglandular hyperplasia or double adenomas.</p

    Reversal of the hanging protocol of Contrast Enhanced Mammography leads to similar diagnostic performance yet decreased reading times

    Get PDF
    Objectives: Contrast-enhanced mammography (CEM) was found superior to Full-Field Digital Mammography (FFDM) for breast cancer detection. Current hanging protocols show low-energy (LE, similar to FFDM) images first, followed by recombined (RC) images. However, evidence regarding which hanging protocol leads to the most efficient reading process and highest diagnostic performance is lacking. This study investigates the effects of hanging-protocol ordering on the reading process and diagnostic performance of breast radiologists using eye-tracking methodology. Furthermore, it investigates differences in reading processes and diagnostic performance between LE, RC and FFDM images. Materials and methods: Twenty-seven breast radiologists were randomized into three reading groups: LE–RC (commonly used hangings), RC-LE (reversed hangings) and FFDM. Thirty cases (nine malignant) were used. Fixation count, net dwell time and time-to-first fixation on malignancies as visual search measures were registered by the eye-tracker. Reading time per image was measured. Participants clicked on suspicious lesions to determine sensitivity and specificity. Area-under-the-ROC-curve (AUC) values were calculated. Results: RC-LE scored identical on visual search measures, t(16)= -1.45, p =.17 or higher-p values, decreased reading time with 31%, t(16)= -2.20, p =.04, while scoring similar diagnostic performance compared to LE-RC, t(13.2)= -1.39, p -.20 or higher p-values. The reading process was more efficient on RC compared to LE. Diagnostic performance of CEM was superior to FFDM; F (2,26)= 16.1, p <.001. Average reading time did not differ between the three groups, F (2,25)= 3.15, p =.06. Conclusion: The reversed CEM hanging protocol (RC-LE) scored similar on diagnostic performance compared to LE-RC, while reading time was a third faster. Abnormalities were interpreted quicker on RC images. A RC-LE hanging protocol is therefore recommended for clinical practice and training. Diagnostic performance of CEM was (again) superior to FFDM

    Preoperative imaging in primary hyperparathyroidism patients using 4DCT subtraction maps, a report of three cases

    No full text
    Four-dimensional computed tomography (4DCT) is one of the preoperative imaging modalities that can be used to localize a parathyroid adenoma in primary hyperparathyroidism patients however, sensitivity differs in literature and could be improved especially for multiglandular hyperplasia or double adenomas. The most robust feature on the 4DCT for the differentiation between parathyroid adenoma and thyroid gland tissue is arterial enhancement. To make this better visible, we have developed a subtraction map that shows arterial enhancement as a color scale to increase sensitivity for 4DCT. In this report of 3 cases, we present the usefulness of this subtraction map in a 54-year-old male, a 57-year-old female and a 51-year-old male. Subtraction maps may increase sensitivity for 4DCT, especially for multiglandular hyperplasia or double adenomas

    Reversal of the hanging protocol of Contrast Enhanced Mammography leads to similar diagnostic performance yet decreased reading times

    No full text
    Objectives: Contrast-enhanced mammography (CEM) was found superior to Full-Field Digital Mammography (FFDM) for breast cancer detection. Current hanging protocols show low-energy (LE, similar to FFDM) images first, followed by recombined (RC) images. However, evidence regarding which hanging protocol leads to the most efficient reading process and highest diagnostic performance is lacking. This study investigates the effects of hanging-protocol ordering on the reading process and diagnostic performance of breast radiologists using eye-tracking methodology. Furthermore, it investigates differences in reading processes and diagnostic performance between LE, RC and FFDM images. Materials and methods: Twenty-seven breast radiologists were randomized into three reading groups: LE–RC (commonly used hangings), RC-LE (reversed hangings) and FFDM. Thirty cases (nine malignant) were used. Fixation count, net dwell time and time-to-first fixation on malignancies as visual search measures were registered by the eye-tracker. Reading time per image was measured. Participants clicked on suspicious lesions to determine sensitivity and specificity. Area-under-the-ROC-curve (AUC) values were calculated. Results: RC-LE scored identical on visual search measures, t(16)= -1.45, p =.17 or higher-p values, decreased reading time with 31%, t(16)= -2.20, p =.04, while scoring similar diagnostic performance compared to LE-RC, t(13.2)= -1.39, p -.20 or higher p-values. The reading process was more efficient on RC compared to LE. Diagnostic performance of CEM was superior to FFDM; F (2,26)= 16.1, p <.001. Average reading time did not differ between the three groups, F (2,25)= 3.15, p =.06. Conclusion: The reversed CEM hanging protocol (RC-LE) scored similar on diagnostic performance compared to LE-RC, while reading time was a third faster. Abnormalities were interpreted quicker on RC images. A RC-LE hanging protocol is therefore recommended for clinical practice and training. Diagnostic performance of CEM was (again) superior to FFDM

    Reversal of the hanging protocol of Contrast Enhanced Mammography leads to similar diagnostic performance yet decreased reading times

    No full text
    Objectives: Contrast-enhanced mammography (CEM) was found superior to Full-Field Digital Mammography (FFDM) for breast cancer detection. Current hanging protocols show low-energy (LE, similar to FFDM) images first, followed by recombined (RC) images. However, evidence regarding which hanging protocol leads to the most efficient reading process and highest diagnostic performance is lacking. This study investigates the effects of hanging-protocol ordering on the reading process and diagnostic performance of breast radiologists using eye-tracking methodology. Furthermore, it investigates differences in reading processes and diagnostic performance between LE, RC and FFDM images. Materials and methods: Twenty-seven breast radiologists were randomized into three reading groups: LE–RC (commonly used hangings), RC-LE (reversed hangings) and FFDM. Thirty cases (nine malignant) were used. Fixation count, net dwell time and time-to-first fixation on malignancies as visual search measures were registered by the eye-tracker. Reading time per image was measured. Participants clicked on suspicious lesions to determine sensitivity and specificity. Area-under-the-ROC-curve (AUC) values were calculated. Results: RC-LE scored identical on visual search measures, t(16)= -1.45, p =.17 or higher-p values, decreased reading time with 31%, t(16)= -2.20, p =.04, while scoring similar diagnostic performance compared to LE-RC, t(13.2)= -1.39, p -.20 or higher p-values. The reading process was more efficient on RC compared to LE. Diagnostic performance of CEM was superior to FFDM; F (2,26)= 16.1, p <.001. Average reading time did not differ between the three groups, F (2,25)= 3.15, p =.06. Conclusion: The reversed CEM hanging protocol (RC-LE) scored similar on diagnostic performance compared to LE-RC, while reading time was a third faster. Abnormalities were interpreted quicker on RC images. A RC-LE hanging protocol is therefore recommended for clinical practice and training. Diagnostic performance of CEM was (again) superior to FFDM
    corecore