3 research outputs found

    Functional intercomparison of intraoperative radiotherapy equipment โ€“ Photon Radiosurgery System

    Get PDF
    BACKGROUND: Intraoperative Radiotherapy (IORT) is a method by which a critical radiation dose is delivered to the tumour bed immediately after surgical excision. It is being investigated whether a single high dose of radiation will impart the same clinical benefit as a standard course of external beam therapy. Our centre has four Photon Radiosurgery Systems (PRS) currently used to irradiate breast and neurological sites. MATERIALS AND METHODS: The PRS comprises an x-ray generator, control console, quality assurance tools and a mobile gantry. We investigated the dosimetric characteristics of each source and its performance stability over a period of time. We investigated half value layer, output diminution factor, internal radiation monitor (IRM) reproducibility and depth-doses in water. The half value layer was determined in air by the broad beam method, using high purity aluminium attenuators. To quantify beam hardening at clinical depths, solid water attenuators of 5 and 10 mm were placed between the x-ray probe and attenuators. The ion chamber current was monitored over 30 minutes to deduce an output diminution factor. IRM reproducibility was investigated under various exposures. Depth-dose curves in water were obtained at distances up to 35 mm from the probe. RESULTS: The mean energies for the beam attenuated by 5 and 10 mm of solid water were derived from ICRU Report 17 and found to be 18 and 24 keV. The average output level over a period of 30 minutes was found to be 99.12%. The average difference between the preset IRM limit and the total IRM count was less than 0.5%. For three x-ray sources, the average difference between the calculated and actual treatment times was found to be 0.62% (n = 30). The beam attenuation in water varied by approximately 1/r(3). CONCLUSION: The x-ray sources are stable over time. Most measurements were found to lie within the manufacturer's tolerances and an intercomparison of these checks suggests that the four x-ray sources have similar performance characteristics

    Dosimetric Comparison and Potential for Improved Clinical Outcomes of Paediatric CNS Patients Treated with Protons or IMRT

    No full text
    Background: We compare clinical outcomes of paediatric patients with CNS tumours treated with protons or IMRT. CNS tumours form the second most common group of cancers in children. Radiotherapy plays a major role in the treatment of many of these patients but also contributes to late side effects in long term survivors. Radiation dose inevitably deposited in healthy tissues outside the clinical target has been linked to detrimental late effects such as neurocognitive, behavioural and vascular effects in addition to endocrine abnormalities and second tumours. Methods: A literature search was performed using keywords: protons, IMRT, CNS and paediatric. Of 189 papers retrieved, 10 were deemed relevant based on title and abstract screening. All papers directly compared outcomes from protons with photons, five papers included medulloblastoma, four papers each included craniopharyngioma and low grade gliomas and three papers included ependymoma. Results: This review found that while proton beam therapy offered similar clinical target coverage, there was a demonstrable reduction in integral dose to normal structures. Conclusions: This in turn suggests the potential for superior long term outcomes for paediatric patients with CNS tumours both in terms of radiogenic second cancers and out-of-field adverse effects
    corecore