84 research outputs found

    The bright and the dark sides of brachytherapy: mechanisms of stenosis reduction and findings of intracoronary β-radiation therapy revealed by IVUS-3D and QCA

    Get PDF
    Sincethe first percutaneous coronary intervention, 24 years ago, the field of interventional cardiology has continued to grow rapidly. Although PTCA has demonstrated superiority to medical therapy in alleviating angina, restenosis and acute closure of the treated vessel remained major limitations. Stent has improved both problems by preventing residual dissection, elastic recoil and negative remodeling. However, the occurrence of restenosis after stenting remains unresolved. Furthermore, in-stent restenosis has become a new enemy in the field of interventional cardiology, since the conventional treatment of in-stent restenosis is rather disappointing with high restenosis rates (around 30 - 70%). Therefore, the holy grail to overcome this immense enemy went unabated. Intracoronary brachytherapy is a powerful therapy to prevent restenosis after percutaneous transluminal coronary intervention. The purpose of this thesis is to explore the mechanism of action of intracoronary radiation and the problems related to this procedure. For this purpose, three-dimensional intravascular ultrasound (IVUS) and quantitative coronary angiography (QCA) were applied as investigational tools. This thesis consists of 2 parts; the first part deals with the positive aspect of intracoronary brachytherapy which explains its increasing application (Chapter 2) and its mechanistic interpretation (Chapters 3-7). The second part reports on the dark sides of intracoronary brachytherapy (Chapters 8-12)

    Radioactive stents delay but do not prevent in-stent neointimal hyperplasia

    Get PDF
    BACKGROUND: Restenosis after conventional stenting is almost exclusively caused by neointimal hyperplasia. Beta-particle-emitting radioactive stents decrease in-stent neointimal hyperplasia at 6-month follow-up. The purpose of this study was to evaluate the 1-year outcome of (32)P radioactive stents with an initial activity of 6 to 12 microCi using serial quantitative coronary angiography and volumetric ECG-gated 3D intravascular ultrasound (IVUS). METHODS AND RESULTS: Of 40 patients undergoing initial stent implantation, 26 were event-free after the 6-month follow-up period and 22 underwent repeat catheterization and IVUS at 1 year; they comprised half of the study population. Significant luminal deterioration was observed within the stents between 6 months and 1 year, as evidenced by a decrease in the angiographic minimum lumen diameter (-0.43+/-0.56 mm; P:=0.028) and in the mean lumen diameter in the stent (-0.55+/-0. 63 mm; P:=0.001); a significant increase in in-stent neointimal hyperplasia by IVUS (18.16+/-12.59 mm(3) at 6 months to 27.75+/-11. 99 mm(3) at 1 year; P:=0.001) was also observed. Target vessel revascularization was performed in 5 patients (23%). No patient experienced late occlusion, myocardial infarction, or death. By 1 year, 21 of the initial 40 patients (65%) remained event-free. CONCLUSIONS: Neointimal proliferation is delayed rather than prevented by radioactive stent implantation. Clinical outcome 1 year after the implantation of stents with an initial activity of 6 to 12 microCi is not favorable when compared with conventional stenting

    Geographic miss: a cause of treatment failure in radio-oncology applied to intracoronary radiation therapy

    Get PDF
    BACKGROUND: A recognized limitation of endovascular beta-radiation therapy is the development of new stenosis at the edges of the irradiated area. The combination of injury and low-dose radiation may be the precursor of this phenomenon. We translated the radio-oncological concept of "geographic miss" to define cases in which the radiation source did not fully cover the injured area. The aims of the study were to determine the incidence and causes of geographic miss and evaluate the impact of this inadequate treatment on the outcome of patients treated with intracoronary beta-radiation. METHODS AND RESULTS: We analyzed 50 consecutive patients treated with beta-radiation after percutaneous coronary intervention. The prescribed dose ranged between 12 and 20 Gy at 2 mm from the source axis. By means of quantitative coronary angiography, the irradiated segment (IRS) and both edges were studied before and after intervention and at 6-month follow-up. Edges that were injured during the procedure constituted the geographic miss edges. Twenty-two edges were injured during the intervention, mainly because of procedural complications that extended the treatment beyond the margins of the IRS. Late loss was significantly higher in geographic miss edges than in IRSs and uninjured edges (0.84+/-0.6 versus 0.15+/-0.4 and 0.09+/-0.4 mm, respectively; P<0.0001). Similarly, restenosis rate was significantly higher in the injured edges (10% within IRS, 40.9% in geographic miss edges, and 1.9% in uninjured edges; P<0.001). CONCLUSIONS: These data support the hypothesis that the combination of injury and low-dose beta-radiation induces deleterious outcome

    Geographic Miss

    Get PDF
    Background—A recognized limitation of endovascular ß-radiation therapy is the development of new stenosis at the edges of the irradiated area. The combination of injury and low-dose radiation may be the precursor of this phenomenon. We translated the radio-oncological concept of "geographic miss" to define cases in which the radiation source did not fully cover the injured area. The aims of the study were to determine the incidence and causes of geographic miss and evaluate the impact of this inadequate treatment on the outcome of patients treated with intracoronary ß-radiation. Methods and Results—We analyzed 50 consecutive patients treated with ß-radiation after percutaneous coronary intervention. The prescribed dose ranged between 12 and 20 Gy at 2 mm from the source axis. By means of quantitative coronary angiography, the irradiated segment (IRS) and both edges were studied before and after intervention and at 6-month follow-up. Edges that were injured during the procedure constituted the geographic miss edges. Twenty-two edges were injured during the intervention, mainly because of procedural complications that extended the treatment beyond the margins of the IRS. Late loss was significantly higher in geographic miss edges than in IRSs and uninjured edges (0.84±0.6 versus 0.15±0.4 and 0.09±0.4 mm, respectively; P<0.0001). Similarly, restenosis rate was significantly higher in the injured edges (10% within IRS, 40.9% in geographic miss edges, and 1.9% in uninjured edges; P<0.001). Conclusions—These data support the hypothesis that the combination of injury and low-dose ß-radiation induces deleterious outcome
    corecore