15 research outputs found

    Six weeks Use of a Wearable Soft-robotic Glove During ADL:Preliminary Results of Ongoing Clinical Study

    Get PDF
    In this ongoing study, an assistive wearable soft-robotic glove, named Carbonhand, is tested at home for 6 weeks by subjects with decreased handgrip strength to receive a first insight in the therapeutic effect of using this assistive grip-supporting glove during ADLs. Preliminary results of the first 13 participants showed that participants appreciated use of the glove to assist them with daily life activities. Even more, grip strength without glove improved and functional performance showed increases as well. These preliminary findings hold promise for observing a clinical effect of using the soft-robotic glove as assistance in ADLs upon completion of data collection

    Therapy effect on hand function after home use of a wearable assistive soft-robotic glove supporting grip strength

    Get PDF
    Background Soft-robotic gloves with an assist-as-needed control have the ability to assist daily activities where needed, while stimulating active and highly functional movements within the user’s possibilities. Employment of hand activities with glove support might act as training for unsupported hand function. Objective To evaluate the therapeutic effect of a grip-supporting soft-robotic glove as an assistive device at home during daily activities. Methods This multicentre intervention trial consisted of 3 pre-assessments (averaged if steady state = PRE), one post-assessment (POST), and one follow-up assessment (FU). Participants with chronic hand function limitations were included. Participants used the Carbonhand glove during six weeks in their home environment on their most affected hand. They were free to choose which activities to use the glove with and for how long. The primary outcome measure was grip strength, secondary outcome measures were pinch strength, hand function and glove use time. Results 63 patients with limitations in hand function resulting from various disorders were included. Significant improvements (difference PRE-POST) were found for grip strength (+1.9 kg, CI 0.8 to 3.1; p = 0.002) and hand function, as measured by Jebson-Taylor Hand Function Test (-7.7 s, CI -13.4 to -1.9; p = 0.002) and Action Research Arm Test (+1.0 point, IQR 2.0; p≤0.001). Improvements persisted at FU. Pinch strength improved slightly in all fingers over six-week glove use, however these differences didn’t achieve significance. Participants used the soft-robotic glove for a total average of 33.0 hours (SD 35.3), equivalent to 330 min/week (SD 354) or 47 min/day (SD 51). No serious adverse events occurred. Conclusion The present findings showed that six weeks use of a grip-supporting soft-robotic glove as an assistive device at home resulted in a therapeutic effect on unsupported grip strength and hand function. The glove use time also showed that this wearable, lightweight glove was able to assist participants with the performance of daily tasks for prolonged periods

    Assessment of a two-channel implantable peroneal nerve stimulator post-stroke

    Get PDF
    Thesis outline and aims: to progress towards evidence based application of PNS to improve lower extremity function, the aim of the present thesis is to evaluate an implantable two-channel peroneal nerve stimulator versus conventional splinting as a treatment option for chronic stroke patients with a dropped foot. In chapter 2 a systematic review is described on the available evidence on the improvement of walking in stroke patients with a dropped foot when using PNS. Trials were identified that investigated the orthotic effect of FES on walking. All included studies were scored on methodological quality and studies that measured walking speed were pooled and a pooled difference including confidence interval was calculated. The review concludes that PNS seems to have a positive orthotic effect on walking speed in stroke patients with a dropped foot

    The Sensitivity and Selectivity of an Implantable Two-Channel Peroneal Nerve Stimulator System for Restoration of Dropped Foot

    Get PDF
    The objective of this study was to evaluate the stimulation responses on each channel of an implantable two-channel stimulator that stimulates the peroneal nerve branches innervating the muscles for dorsiflexion and eversion movements. Currently five Dutch patients and five English patients have been implanted with this system. Isometric ankle torque measurements were carried out in the patient with the longest follow-up period (1 y). A force sensor measured the three components of moment generated at the ankle joint. Stimulation intensity can be adjusted with great accuracy. Dorsiflexion moments are almost entirely determined by the setting of channel 1. Eversion moments are determined mainly by channel 2 and to a lesser extent by channel 1. Both channels determined abduction/adduction moments. We conclude that stimulation responses in both dorsiflexion and eversion direction can be set individually and with great accuracy and are reproducible over a prolonged period

    Therapeutic effect of an implantable peroneal nerve stimulator in subjects with chronic stroke and footdrop: A randomized controlled trial

    Get PDF
    Background and Purpose: Footdrop, characterized by a person's inability to raise the foot at the ankle, is a common problem in patients with stroke. A randomized controlled trial was performed to determine the therapeutic effect of using a new implantable, 2-channel peroneal nerve stimulator for 6 months versus an ankle-foot orthosis (AFO). \ud \ud Subjects: Twenty-nine patients with chronic stroke and footdrop participated in the study. The mean time from stroke was 7.3 years (SD=7.3), and all subjects were community ambulators. \ud \ud Methods: The study used a randomized controlled trial design. The functional electrical stimulation (FES) group received the implantable stimulation system for correction of their footdrop. The control group continued using their conventional walking device (ie, AFO, orthopedic shoes, or no walking device). All subjects were measured at baseline and at weeks 4, 8, 12, and 26 in the gait laboratory. The therapeutic effect of FES on the maximum value of the root mean square (RMSmax) of the tibialis anterior (TA) muscle with both flexed and extended knees and walking speed were selected as the primary outcome measures. The RMSmax of the peroneus longus (PL), gastrocnemius (GS), and soleus (SL) muscles with both flexed and extended knees and muscle activity of the TA muscle of the affected leg during the swing phase of gait were selected as secondary outcome measures. \ud \ud Results: A significantly higher RMSmax of the TA muscle with extended knee was found after using FES. No change in walking speed was found when the stimulator was not switched on. A significantly increased RMSmax of the GS muscle with both flexed and extended knees was found after using FES. \ud \ud Discussion and Conclusion: Functionally, no therapeutic effect of implantable peroneal nerve stimulation was found. However, the significantly increased voluntary muscle output of the TA and GS muscles after the use of FES suggests that there was a certain extent of plasticity in the subjects in this study. \u

    Applying a soft-robotic glove as assistive device and training tool with games to support hand function after stroke: Preliminary results on feasibility and potential clinical impact

    Get PDF
    Recent technological developments regarding wearable soft-robotic devices extend beyond the current application of rehabilitation robotics and enable unobtrusive support of the arms and hands during daily activities. In this light, the HandinMind (HiM) system was developed, comprising a soft-robotic, grip supporting glove with an added computer gaming environment. The present study aims to gain first insight into the feasibility of clinical application of the HiM system and its potential impact. In order to do so, both the direct influence of the HiM system on hand function as assistive device and its therapeutic potential, of either assistive or therapeutic use, were explored. A pilot randomized clinical trial was combined with a cross-sectional measurement (comparing performance with and without glove) at baseline in 5 chronic stroke patients, to investigate both the direct assistive and potential therapeutic effects of the HiM system. Extended use of the soft-robotic glove as assistive device at home or with dedicated gaming exercises in a clinical setting was applicable and feasible. A positive assistive effect of the soft-robotic glove was proposed for pinch strength and functional task performance 'lifting full cans' in most of the five participants. A potential therapeutic impact was suggested with predominantly improved hand strength in both participants with assistive use, and faster functional task performance in both participants with therapeutic application

    The Orthotic Effect of Functional Electrical Stimulation on the Improvement of Walking in Stroke Patients with a Dropped Foot: A Systematic Review\ud

    Get PDF
    Objective  Analysis of the available evidence on the improvement of walking in stroke patients with a dropped foot when using peroneus stimulation.\ud \ud Methods  A systematic review was performed to identify trials that investigated the orthotic effect of functional electrical stimulation (FES) on walking in stroke patients with a dropped foot. Two independent raters scored the methodological quality of the included articles. Walking speed and physiological cost index (PCI) were selected as the primary outcome measures. Studies that measured walking speed were pooled and a pooled difference including confidence interval was calculated.\ud \ud Results  Eight studies were included in the review, of which one was a randomized controlled trial. Methodological score ranged from 8 to 18 out of 19. Six studies measured walking speed. The pooled improvement in walking speed was 0.13 m/s (0.07–0.2) or 38% (22.18–53.8).\ud \ud Conclusions  The present review suggests a positive orthotic effect of functional electrical stimulation on walking speed\u
    corecore