35 research outputs found
Project for the analysis of technology transfer
The special task of preparing technology transfer profiles during the first six months of 1971 produced two major results: refining a new method for identifying and describing technology transfer activities, and generating practical insights into a number of issues associated with transfer programs
Project for the analysis of technology transfer Quarterly reports, 1 Jul. - 31 Dec. 1970
Summary of research activities of Project for Analysis of Technology Transfer for period 1 July - 31 Dec. 197
Accessing numeric data via flags and tags: A final report on a real world experiment
An experiment is reported which: extended the concepts of data flagging and tagging to the aerospace scientific and technical literature; generated experience with the assignment of data summaries and data terms by documentation specialists; and obtained real world assessments of data summaries and data terms in information products and services. Inclusion of data summaries and data terms improved users' understanding of referenced documents from a subject perspective as well as from a data perspective; furthermore, a radical shift in document ordering behavior occurred during the experiment toward proportionately more requests for data-summarized items
Applications of aerospace technology in industry, a technology transfer profile: Fire safety
The fire safety field is considered as being composed of three parts: an industry, a technology base, and a user base. An overview of the field is presented, including a perspective on the magnitude of the national fire safety problem. Selected NASA contributions to the technology of fire safety are considered. Communication mechanisms, particularly conferences and publications, used by NASA to alert the community to new developments in the fire safety field, are reviewed. Several examples of nonaerospace applications of NASA-generated fire safety technology are also presented. Issues associated with attempts to transfer this technology from the space program to other sectors of the American economy are outlined
Applications of aerospace technology in industry, a technology transfer profile: Lubrication
Technology transfer in the lubrication field is discussed in terms of the movement of NASA-generated lubrication technology into the private sector as affected by evolving industrial requirements. An overview of the field is presented, and NASA technical contributions to lubrication technology are described. Specific examples in which these technologies have been used in the private sector are summarized
Program for transfer research and impact studies
Research activities conducted under the Program for Transfer Research and Impact Studies (TRIS) during 1972 included: (1) preparation of 10,196 TSP requests for TRIS application analysis; (2) interviews with over 500 individuals concerning the technical, economic, and social impacts of NASA-generated technology; (3) preparation of 38 new technology transfer example files and 101 new transfer cases; and (4) maintenance of a technology transfer library containing more than 2,900 titles. Six different modes of technology utilization are used to illustrate the pervasiveness of the transfer and diffusion of aerospace innovations. These modes also provide a basis for distinguishing the unique characteristics of the NASA Technology Utilization Program. An examination is reported of the ways in which NASA-generated technology is contributing to beneficial social change in five major areas of human concern: health, environment, safety, transportation, and communication
Recommended from our members
Optimizing surface acoustic wave sensors for trace chemical detection
This paper describes several recent advances for fabricating coated surface acoustic wave (SAW) sensors for applications requiring trace chemical detection. Specifically, we have demonstrated that high surface area microporous oxides can provide 100-fold improvements in SAW sensor responses compared with more typical polymeric coatings. In addition, we fabricated GaAs SAW devices with frequencies up to 500 MHz to provide greater sensitivity and an ideal substrate for integration with high-frequency electronics
Recommended from our members
Design and Testing of a Micro Thermal Conductivity Detector (TCD) System
This work describes the design, simulation, fabrication and characterization of a microfabricated thermal conductivity detector to be used as an extension of the {micro}ChemLab{trademark}. The device geometry was optimized by simulating the heat transfer in the device, utilizing a boundary element algorithm. In particular it is shown that within microfabrication constraints, a micro-TCD optimized for sensitivity can be readily calculated. Two flow patterns were proposed and were subsequently fabricated into nine-promising geometries. The microfabricated detector consists of a slender metal film, supported by a suspended thin dielectric film over a pyramidal or trapezoidal silicon channel. It was demonstrated that the perpendicular flow, where the gas directly impinges on the membrane, creates a device that is 3 times more sensitive than the parallel flow, where the gas passed over the membrane. This resulted in validation of the functionality of a microfabricated TCD as a trace-level detector, utilizing low power. the detector shows a consistent linear response to concentration and they are easily able to detect 100-ppm levels of CO in He. Comparison of noise levels for this analysis indicates that sub part per million (ppm) levels are achievable with the selection of the right set of conditions for the detector to operate under. This detector was originally proposed as part of a high-speed detection system for the petrochemical gas industry. This system was to be utilized as a process monitor to detect reactor ''upset'' conditions before a run away condition could occur (faster than current full-scale monitoring systems were able to achieve). Further outlining of requirements indicated that the detection levels likely achievable with a TCD detector would not be sufficient to meet the process condition needs. Therefore the designed and fabricated detector was integrated into a detection system to showcase some technologies that could further the development of components for the current gas phase {micro}ChemLab as well as future modifications for process monitoring work such as: pressurized connections, gas sampling procedures, and packed columns. Component integration of a microfabricated planar pre-concentrator, gas-chromatograph column and TCD in the separation/detection of hydrocarbons, such as benzene, toluene and xylene (BTX) was also demonstrated with this system
Recommended from our members
Modeling Transport in Gas Chromatography Columns for the Micro-ChemLab
The gas chromatography (GC) column is a critical component in the microsystem for chemical detection ({mu}ChemLab{trademark}) being developed at Sandia. The goal is to etch a meter-long GC column onto a 1-cm{sup 2} silicon chip while maintaining good chromatographic performance. Our design strategy is to use a modeling and simulation approach. We have developed an analytical tool that models the transport and surface interaction process to achieve an optimized design of the GC column. This analytical tool has a flow module and a separation module. The flow module considers both the compressibility and slip flow effects that may significantly influence the gas transport in a long and narrow column. The separation module models analyte transport and physico-chemical interaction with the coated surface in the GC column. It predicts the column efficiency and performance. Results of our analysis will be presented in this paper. In addition to the analytical tool, we have also developed a time-dependent adsorption/desorption model and incorporated this model into a computational fluid dynamics (CFD) code to simulate analyte transport and separation process in GC columns. CFD simulations can capture the complex three-dimensional flow and transport dynamics, whereas the analytical tool cannot. Different column geometries have been studied, and results will be presented in this paper. Overall we have demonstrated that the modeling and simulation approach can guide the design of the GC column and will reduce the number of iterations in the device development
Recommended from our members
Arsenic pilot plant operation and results : Anthony, New Mexico.
Sandia National Laboratories (SNL) is conducting pilot scale evaluations of the performance and cost of innovative water treatment technologies aimed at meeting the recently revised arsenic maximum contaminant level (MCL) for drinking water. The standard of 10 {micro}g/L (10 ppb) is effective as of January 2006. The pilot tests have been conducted in New Mexico where over 90 sites that exceed the new MCL have been identified by the New Mexico Environment Department. The pilot test described in this report was conducted in Anthony, New Mexico between August 2005 and December 2006 at Desert Sands Mutual Domestic Water Consumers Association (MDWCA) (Desert Sands) Well No.3. The pilot demonstrations are a part of the Arsenic Water Technology Partnership program, a partnership between the American Water Works Association Research Foundation (AwwaRF), SNL and WERC (A Consortium for Environmental Education and Technology Development). The Sandia National Laboratories pilot demonstration at the Desert Sands site obtained arsenic removal performance data for fourteen different adsorptive media under intermittent flow conditions. Well water at Desert Sands has approximately 20 ppb arsenic in the unoxidized (arsenite-As(III)) redox state with moderately high total dissolved solids (TDS), mainly due to high sulfate, chloride, and varying concentrations of iron. The water is slightly alkaline with a pH near 8. The study provides estimates of the capacity (bed volumes until breakthrough at 10 ppb arsenic) of adsorptive media in the same chlorinated water. Adsorptive media were compared side-by-side in ambient pH water with intermittent flow operation. This pilot is broken down into four phases, which occurred sequentially, however the phases overlapped in most cases