6 research outputs found

    Deteriorated steel culvert under static loading

    No full text
    The paper describes full-scale tests of a 7,25 m long corrugated steel pipe with a diameter of 1.40 m. The corrugation pattern was 125x26mm and the steel was 2 mm thick. The backfill height over the pipe crown was 0,5 m. The deterioration of the tested steel pipe was simulated by removing a part of its bottom. Strain gauges and optical prisms were installed on the metal surface to determine the stresses, internal forces in the metal shell and additionally its deformation. The results of the measurements are presented as graphs and tables. The main goal of the full-scale tests was to assess the performance of the deteriorated steel pipe subjected to static loads and to evaluate the changes in the distribution of the internal forces, caused by the increasing corrosion of the bottom part of the tested pipe

    Deteriorated steel culvert under static loading

    No full text
    The paper describes full-scale tests of a 7,25 m long corrugated steel pipe with a diameter of 1.40 m. The corrugation pattern was 125x26mm and the steel was 2 mm thick. The backfill height over the pipe crown was 0,5 m. The deterioration of the tested steel pipe was simulated by removing a part of its bottom. Strain gauges and optical prisms were installed on the metal surface to determine the stresses, internal forces in the metal shell and additionally its deformation. The results of the measurements are presented as graphs and tables. The main goal of the full-scale tests was to assess the performance of the deteriorated steel pipe subjected to static loads and to evaluate the changes in the distribution of the internal forces, caused by the increasing corrosion of the bottom part of the tested pipe

    Ultracor - 1-st realization in Europe, design, erection, testing

    No full text
    This paper presents design, realization and testing process of 1-st UltraCor structure in Europe. The scope of the design and intalation is 25.50 m Span, 9.00 m Rise structural plate structure of 500x237mm corrugation with only 9.5 mm plate thickness. Structure will cary the heavy traffic of S7 express road. It was designed for the highest class of loads acc. to Polish Standard. Under the structure there is a local raod and animal crossing

    Ultracor - 1-st realization in Europe, design, erection, testing

    No full text
    This paper presents design, realization and testing process of 1-st UltraCor structure in Europe. The scope of the design and intalation is 25.50 m Span, 9.00 m Rise structural plate structure of 500x237mm corrugation with only 9.5 mm plate thickness. Structure will cary the heavy traffic of S7 express road. It was designed for the highest class of loads acc. to Polish Standard. Under the structure there is a local raod and animal crossing
    corecore