13 research outputs found

    Late onset of new conduction disturbances requiring permanent pacemaker implantation following TAVI

    Get PDF
    Background: The timing of onset and associated predictors of late new conduction disturbances (CDs) leading to permanent pacemaker implantation (PPI) following transcatheter aortic valve implantation (TAVI) are still unknown, however, essential for an early and safe discharge. This study aimed to investigate the timing of onset and associated predictors of late onset CDs in patients requiring PPI (LCP) following TAVI. Methods and results: We performed retrospective analysis of prospectively collected data from five large volume centres in Europe. Post-TAVI electrocardiograms and telemetry data were evaluated in patients with a PPI post-TAVI to identify the onset of new advanced CDs. Early onset CDs were defined as within 48 hours after procedure, and late onset CDs as after 48 hours. A total of 2804 patients were included for analysis. The PPI rate was 12%, of which 18% was due to late onset CDs (>48 hours). Independent predictors for LCP were pre-existing non-specific intraventricular conduction delay, pre-existing right bundle branch block, self-expandable valves and predilation. At least one of these risk factors was present in 98% of patients with LCP. Patients with a balloon-expandable valve without predilation did not develop CDs requiring PPI after 48 hours. Conclusions: Safe early discharge might be feasible in patients without CDs in the first 48 hours after TAVI if no risk factors for LCP are present

    Comparison of the Sapien 3 versus the ACURATE neo valve system: A propensity score analysis

    Get PDF
    Objectives: To compare the outcomes of transfemoral ACURATE neo (NEO) and Sapien 3 (S3) patients in terms of device success and clinical safety outcomes using a propensity score analysis. Background: Differences in clinical outcomes between the latest-generation balloon-expandable S3 and self-expanding NEO in a “real-world transfemoral TAVI population” are still unclear. Methods: We compared up to 6 months clinical outcomes using a propensity s

    Comparison of the Sapien 3 versus the ACURATE neo valve system: A propensity score analysis

    Get PDF
    Objectives: To compare the outcomes of transfemoral ACURATE neo (NEO) and Sapien 3 (S3) patients in terms of device success and clinical safety outcomes using a propensity score analysis. Background: Differences in clinical outcomes between the latest-generation balloon-expandable S3 and self-expanding NEO in a “real-world transfemoral TAVI population” are still unclear. Methods: We compared up to 6 months clinical outcomes using a propensity score analysis (inverse probability of treatment weighting [IPTW]) to account for differences in baseline characteristics. Results: A total of 345 patients underwent transfemoral transcatheter aortic valve implantation (TAVI) with either NEO or S3 at two centers in the Netherlands. Composite device success and early safety endpoints were comparable between NEO and S3 (Device success: IPTW-adjusted OR: 0.35 [95% CI: 0.12–1.18], and early safety: IPTW-adjusted OR: 0.51 [95% CI: 0.19–1.38]). Six-months mortality was 5.3 versus 3.6%, stroke was 2.8 versus 3.3%, and pacemaker rate was 6.1 versus 8.6%, respectively with p = NS. Mean aortic gradient was lower in the NEO group (5.72 ± 2.47 vs. 9.05 ± 3.48; p = <.001), with a comparable rate of moderate or severe paravalvular leak (0 versus 2.1%; p = NS). Conclusions: Device success and clinical safety outcomes were comparable for both valves. Up to 6-months follow-up clinical outcomes and mortality rate remained excellent. Mean aortic gradient was lower after ACURATE neo implantation

    Intraoperative hypotension and delirium among older adults undergoing transcatheter aortic valve replacement

    Get PDF
    Background: Postoperative delirium (POD) is a frequently observed complication after transcatheter aortic valve replacement (TAVR). The effects of intraoperative hypotension (IOH) on POD occurrence are currently unclear. Methods: A retrospective observational cohort study of patients who underwent TAVR was conducted. We predefined IOH as area under the threshold (AUT) of five mean arterial blood pressures (MBP), varying from <100 to <60 mmHg. The AUT consisted of the combination of duration and depth under the MBP thresholds, expressed in mmHg*min. All MBP AUTs were computed based on the complete procedure, independent of procedural phase or duration. Results: This cohort included 675 patients who underwent TAVR under general anesthesia (n = 128, 19%) or procedural sedation (n = 547, 81%). Delirium occurred mostly during the first 2 days after TAVR, and was observed in n = 93 (14%) cases. Furthermore, 674, 672, 663, 630, and 518 patients had at least 1 min intraoperative MBP <100, <90, <80, <70, and <60 mmHg, respectively. Patients who developed POD had higher AUT based on all five MBP thresholds during TAVR. The penalized adjusted odds ratio varied between 1.08 (99% confidence interval [CI] 0.74–1.56) for the AUT based on MBP < 100 mmHg and OR 1.06 (99% CI 0.88–1.28) for the AUT based on MBP < 60 mmHg. Conclusions: Intraoperative hypotension is frequently observed during TAVR, but not independently associated with POD after TAVR. Other potential factors than intraoperative hypotension may explain the occurrence of delirium after TAVR

    From blood to lung tissue:effect of cigarette smoke on DNA methylation and lung function

    Get PDF
    Background: Genetic and environmental factors play a role in the development of COPD. The epigenome, and more specifically DNA methylation, is recognized as important link between these factors. We postulate that DNA methylation is one of the routes by which cigarette smoke influences the development of COPD. In this study, we aim to identify CpG-sites that are associated with cigarette smoke exposure and lung function levels in whole blood and validate these CpG-sites in lung tissue. Methods: The association between pack years and DNA methylation was studied genome-wide in 658 current smokers with >5 pack years using robust linear regression analysis. Using mediation analysis, we subsequently selected the CpG-sites that were also associated with lung function levels. Significant CpG-sites were validated in lung tissue with pyrosequencing and expression quantitative trait methylation (eQTM) analysis was performed to investigate the association between DNA methylation and gene expression. Results: 15 CpG-sites were significantly associated with pack years and 10 of these were additionally associated with lung function levels. We validated 5 CpG-sites in lung tissue and found several associations between DNA methylation and gene expression. Conclusion: This study is the first to validate a panel of CpG-sites that are associated with cigarette smoking and lung function levels in whole blood in the tissue of interest: lung tissue

    LV systolic dysfunction stands to gain the most post transcatheter aortic valve implantation (TAVI)

    No full text
    AIMS: We aimed to evaluate the extent of left ventricular (LV) recovery post transcatheter aortic valve implantation (TAVI) and its clinical predictors. METHODS AND RESULTS: This was a retrospective study on patients treated with TAVI from August 2008 to September 2017. Patients were sub-classified according to their baseline LV function as normal, mildly impaired, moderately impaired or severely impaired. Echo pre TAVI and early post TAVI were compared to assess LV function change. Predictors of LV function change were sought from univariate and multivariate ordinal logistic regression analyses. There were 662 patients included in this study. Nearly half of them, 323 patients (49%), had abnormal LV systolic dysfunction of various degrees. Of these, 193 (60%) showed LV function improvement post TAVI. Based on their pre-TAVI LV function, 55% of the mild LV dysfunction cohort, 62% of the moderate LV dysfunction cohort and 74% of the severe LV dysfunction cohort had LV function improvement post TAVI. Multivariate logistic regression analysis revealed baseline LV dysfunction as the only significant predictor of LV function improvement post TAVI. CONCLUSIONS: The majority of patients with baseline LV dysfunction had LV improvement post TAVI, more so those patients with severe LV dysfunction

    Ex Vivo Pilot Study of Cardiac Magnetic Resonance Velocity Mapping for Quantification of Aortic Regurgitation in a Porcine Model in the Presence of a Transcatheter Heart Valve

    Get PDF
    Accuracy of aortic regurgitation (AR) quantification by magnetic resonance (MR) imaging in the presence of a transcatheter heart valve (THV) remains to be established. We evaluated the accuracy of cardiac MR velocity mapping for quantification of antegrade flow (AF) and retrograde flow (RF) across a THV and the optimal slice position to use in cardiac MR imaging. In a systematic and fully controlled laboratory ex vivo setting, two THVs (Edwards SAPIEN XT, Medtronic CoreValve) were tested in a porcine model (n = 1) under steady flow conditions. Results showed a high level of accuracy and precision. For both THVs, AF was best measured at left ventricular outflow tract level, and RF at ascending aorta level. At these levels, MR had an excellent repeatability (ICC > 0.99), with a tendency to overestimate (4.6 ± 2.4% to 9.4 ± 7.0%). Quantification of AR by MR velocity mapping in the presence of a THV was accurate, precise, and repeatable in this pilot study, when corrected for the systematic error and when the best MR slice position was used. Confirmation of these results in future clinical studies would be a step forward in increasing the accuracy of the assessment of paravalvular AR severity

    Ex Vivo Pilot Study of Cardiac Magnetic Resonance Velocity Mapping for Quantification of Aortic Regurgitation in a Porcine Model in the Presence of a Transcatheter Heart Valve

    No full text
    Accuracy of aortic regurgitation (AR) quantification by magnetic resonance (MR) imaging in the presence of a transcatheter heart valve (THV) remains to be established. We evaluated the accuracy of cardiac MR velocity mapping for quantification of antegrade flow (AF) and retrograde flow (RF) across a THV and the optimal slice position to use in cardiac MR imaging. In a systematic and fully controlled laboratory ex vivo setting, two THVs (Edwards SAPIEN XT, Medtronic CoreValve) were tested in a porcine model (n = 1) under steady flow conditions. Results showed a high level of accuracy and precision. For both THVs, AF was best measured at left ventricular outflow tract level, and RF at ascending aorta level. At these levels, MR had an excellent repeatability (ICC > 0.99), with a tendency to overestimate (4.6 ± 2.4% to 9.4 ± 7.0%). Quantification of AR by MR velocity mapping in the presence of a THV was accurate, precise, and repeatable in this pilot study, when corrected for the systematic error and when the best MR slice position was used. Confirmation of these results in future clinical studies would be a step forward in increasing the accuracy of the assessment of paravalvular AR severity

    Impact of baseline cigarette smoking status on clinical outcome after transcatheter aortic valve replacement

    No full text
    OBJECTIVES: To explore the prevalence of smoking, and its association with clinical and mortality outcome among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Less data exist regarding the effect of baseline smoking status on clinical and mortality outcome among patients undergoing TAVR. METHODS: Consecutive patients who underwent TAVR at two high volume Dutch centers were included. Smoking status was prospectively questioned by a structured interview at admission. Primary endpoint was 1-year all-cause mortality after TAVR. RESULTS: A total of 913 consecutive patients (80.1 ± 7.6 years; logistic EuroSCORE: 16.5 ± 9.9%) who underwent TAVR for severe aortic valve stenosis were included. There were 47% (n = 432) males, and 57% (n = 522) never-smokers, and 35% (n = 317) prior-smokers, and 8% (n = 74) current-smokers. Smokers (i.e., prior-smokers or current-smokers) were younger compared to never-smokers (78.9 ± 7.9 and 76.4 ± 8.0 vs. 81.3 ± 7.1, P < 0.000, respectively). Median follow-up time was 365 (interquartile range [IQR]: 280-365) days. Overall, prior-smoking was not associated with all-cause mortality at 1-year following TAVR (hazard ratio [HR] 0.83, 95% confidence interval [CI] 0.55-1.23). After stratification according to sex, male prior-smokers showed better 1-year survival after TAVR than male never-smokers (12% vs. 20%; P = 0.018, respectively, HR 0.52, 95% CI 0.29-0.89), while this reversed effect was not observed among female prior-smokers versus female never-smokers after TAVR (HR 1.70, 95% CI 0.95-3.05). CONCLUSIONS: Overall, baseline prior-smokers had similar 1-year mortality outcome after TAVR compared with baseline never-smokers. However, there was a reversed association between baseline prior-smoking status and 1-year mortality after TAVR among males, which could partially be explained due to the favorable baseline characteristics
    corecore