23 research outputs found
In Vivo Microwave Ablation of Normal Swine Lung at High-power, Short-duration Settings
To evaluate the volume and heat-sink effects of microwave ablation (MWA) in the ablation zone of the normal swine lung. MWA at 100 W was performed for 1, 2, and 3 min in 7, 5, and 5 lung zones, respectively. We assessed the histopathology in the ablation zones and other outcome measures: namely, length of the longest long and short axes, sphericity, ellipsoid area, and ellipsoid volume. The mean long- and short-axis diameters were 22.0 and 14.1 mm in the 1-min ablation zone, 27.6 and 20.2 mm in the 2-min ablation zone; and 29.2 and 21.2 mm in the 3-min ablation zone, respectively. All measures, except sphericity, were significantly less with 1-min ablation than with either 2- or 3-min ablation. There were no significant differences between the 2- and 3-min ablation zones, but all measures except sphericity were larger with 3-min ablation. Although there were no blood vessels that resulted in a heat-sink effect within the ablation zones, the presence of bronchi nearby in 5 lung ablation zones resulted in reduced ablation size. In high-power, short-duration MWA, the lung ablation volume was affected by ablation time. Some ablations showed that a heat-sink effect by a neighboring bronchus might occur
Zerobot®: A Remote-controlled Robot for Needle Insertion in CT-guided Interventional Radiology Developed at Okayama University
Since 2012, we have been developing a remote-controlled robotic system (Zerobot®) for needle insertion during computed tomography (CT)-guided interventional procedures, such as ablation, biopsy, and drainage. The system was designed via a collaboration between the medical and engineering departments at Okayama University, including various risk control features. It consists of a robot with 6 degrees of freedom that is manipulated using an operation interface to perform needle insertions under CT-guidance. The procedure includes robot positioning, needle targeting, and needle insertion. Phantom experiments have indicated that robotic insertion is equivalent in accuracy to manual insertion, without physician radiation exposure. Animal experiments have revealed that robotic insertion of biopsy introducer needles and various ablation needles is safe and accurate in vivo. The first in vivo human trial, therefore, began in April 2018. After its completion, a larger clinical study will be conducted for commercialization of the robot. This robotic procedure has many potential advantages over a manual procedure: 1) decreased physician fatigue; 2) stable and accurate needle posture without tremor; 3) procedure automation; 4) less experience required for proficiency in needle insertion skills; 5) decreased variance in technical skills among physicians; and 6) increased likelihood of performing the procedure at remote hospitals (i.e., telemedicine)
Robotic CT-guided out-of-plane needle insertion: comparison of angle accuracy with manual insertion in phantom and measurement of distance accuracy in animals
Objectives
To evaluate the accuracy of robotic CT-guided out-of-plane needle insertion in phantom and animal experiments.
Methods
A robotic system (Zerobot), developed at our institution, was used for needle insertion. In the phantom experiment, 12 robotic needle insertions into a phantom at various angles in the XY and YZ planes were performed, and the same insertions were manually performed freehand, as well as guided by a smartphone application (SmartPuncture). Angle errors were compared between the robotic and smartphone-guided manual insertions using Student’s t test. In the animal experiment, 6 robotic out-of-plane needle insertions toward targets of 1.0 mm in diameter placed in the kidneys and hip muscles of swine were performed, each with and without adjustment of needle orientation based on reconstructed CT images during insertion. Distance accuracy was calculated as the distance between the needle tip and the target center.
Results
In the phantom experiment, the mean angle errors of the robotic, freehand manual, and smartphone-guided manual insertions were 0.4°, 7.0°, and 3.7° in the XY plane and 0.6°, 6.3°, and 0.6° in the YZ plane, respectively. Robotic insertions in the XY plane were significantly (p
Conclusion
Robotic CT-guided out-of-plane needle insertions were more accurate than smartphone-guided manual insertions in the phantom and were also accurate in the in vivo procedure, particularly with adjustment during insertion
Combined Laparoscopic and CT Monitoring of the Ice-Ball Margin during Cryoablation for Renal Cell Carcinoma Associated with von Hippel-Lindau Disease: First Case
We report a 47-year-old Japanese female with 10 previous treatments for multiple bilateral renal cell carcinoma (RCC) associated with von Hippel-Lindau disease. The 14-mm right lower pole renal tumor was in contact with the right ureter. Laparoscopic cryoablation was performed to protect the ureter wrapped with gauze. Computed tomography (CT) monitoring was used to confirm the precise ≥ 6 mm ice-ball margin. There was no local progression at 6-months post-surgery. The serum creatinine has been stable. This is apparently the first report of combined laparoscopic and CT monitoring of an ice-ball formation and its margin during cryoablation for RCC
In Vivo Microwave Ablation of Normal Swine Lung at High-power, Short-duration Settings
To evaluate the volume and heat-sink effects of microwave ablation (MWA) in the ablation zone of the normal swine lung. MWA at 100 W was performed for 1, 2, and 3 min in 7, 5, and 5 lung zones, respectively. We assessed the histopathology in the ablation zones and other outcome measures: namely, length of the longest long and short axes, sphericity, ellipsoid area, and ellipsoid volume. The mean long- and short-axis diameters were 22.0 and 14.1 mm in the 1-min ablation zone, 27.6 and 20.2 mm in the 2-min ablation zone; and 29.2 and 21.2 mm in the 3-min ablation zone, respectively. All measures, except sphericity, were significantly less with 1-min ablation than with either 2- or 3-min ablation. There were no significant differences between the 2- and 3-min ablation zones, but all measures except sphericity were larger with 3-min ablation. Although there were no blood vessels that resulted in a heat-sink effect within the ablation zones, the presence of bronchi nearby in 5 lung ablation zones resulted in reduced ablation size. In high-power, short-duration MWA, the lung ablation volume was affected by ablation time. Some ablations showed that a heat-sink effect by a neighboring bronchus might occur
A Nationwide Survey on Danon Disease in Japan
Danon disease, an X-linked dominant cardioskeletal myopathy, is caused by primary deficiency of lysosome-associated membrane protein-2 (LAMP-2). To clarify the clinicopathological features and management, we performed the first nationwide, questionnaire-based survey on Danon disease in Japan. A total of 39 patients (17 males, 22 females) from 20 families were identified in the analysis. All patients had cardiomyopathy. Of the 21 patients who died, 20 (95%) died of cardiac failure or sudden cardiac arrest. Most patients had hypertrophic cardiomyopathy. Wolf⁻Parkinson⁻White syndrome was present at a comparatively high incidence (54% in males, 22% in females). Only one female patient received a heart transplant, which is the most effective therapy. Histopathologically, all male patients showed autophagic vacuoles with sarcolemmal features in muscle. Half of the probands showed de novo mutations. Male patients showed completely absent LAMP-2 expression in muscle. In contrast, female patients showed decreased LAMP-2 expression, which is suggested to reflect LAMP-2 haploinsufficiency due to a heterozygous null mutation. In conclusion, Danon disease is an extremely rare muscular disorder in Japan. Cardiomyopathy is the most significant prognostic factor and the main cause of death. Our findings suggest that the present survey can extend our understanding of the clinical features of this rare disease