125 research outputs found

    A review of outcomes associated with femoral neck lengthening osteotomy in patients with coxa brevis

    Get PDF

    Complex tibial fractures are associated with lower social classes and predict early exit from employment and worse patient-reported QOL:a prospective observational study of 46 complex tibial fractures treated with a ring fixator

    Get PDF
    Abstract The long-term outcomes following complex fractures of the tibia are reported to carry a risk of knee pain, malalignment, articular injury and post-traumatic osteoarthritis. The main objective of this study was to account for the patient-reported quality of life (QOL) 12 months after ring fixator removal in patients with a complex tibial fracture. Secondary objectives included a review of the socio-economic characteristics of the patient group and the rate of return to work in the study period. A prospective follow-up study was conducted of 60 patients with complex fractures of the tibia treated with ring external fixation. Patient-reported outcomes, radiological outcomes and socio-economic status including employment status of the patients were obtained 12 months after frame removal. Forty-six patients completed the assessment 12 months after frame removal (77%). The mean age of the patient at the time of fracture was 54.6 years (range 31–86). There were 19 males and 27 females. At 12 months after frame removal, the mean EQ5D-5L index was 0.66 (CI 0.60–0.72). The mean EQ5D-5L VAS was 69 (CI 61–76). When this was compared to the established reference population from Denmark, the study population showed a significantly worse EQ5D-5L index. The majority of patients (87%) were in the lower social classes suggesting a higher degree of social deprivation in the study population. Twenty-seven per cent of patients who were employed prior to injury had returned to employment at approximately 19 months following fracture. The onset of post-traumatic osteoarthritis was present in the knee joint in 29% of patients following a proximal intra-articular fracture, whereas osteoarthritis was present at the ankle joint in 35% of patients following a distal intra-articular fracture 12 months after frame removal. This study indicates that at 12 months after frame removal there are poorer patient-reported QOL as when compared to reference populations. Furthermore, this study suggests that complex tibial fractures are associated with lower social classes and that only 27% of patients in this sample, who prior to injury were employed, had returned to employment at approximately 19 months after the injury

    Intrarater Reliability of Digital Thermography in Detecting Pin Site Infection:A Proof of Concept Study

    Get PDF
    AIM AND OBJECTIVE: The purpose of this study was to explore the capability and Intrarater reliability of thermography in detecting pin site infection. MATERIALS AND METHODS: This is an explorative proof of concept study. Clinical assessment of pin sites was performed by one examiner with the Modified Gordon Pin Infection Classification from grade 0 to 6. Thermography of the pin sites was performed with a FLIR C3 camera. The analysis of the thermographic images was done in the software FLIR Tools. The maximum skin temperature around the pin site and the maximum temperature for the whole thermographic picture were measured. An Intrarater agreement was established and test-retests were performed with different camera angles. RESULTS: Thirteen (four females, nine males) patients (age 9–72 years) were included. Indications for frames: Fracture (n=4), two deformity correction, one lengthening and six bone transport. Days from surgery to thermography ranged from 27 to 385 days. Overall, 231 pin sites were included. Eleven pin sites were diagnosed with early signs of infection: five grade 1, five grade 2 and one grade 3. Mean pin site temperature for each patient was calculated, varied between patients from 29.0°C to 35.4°C (mean 33.9°C). With 34°C as cut-off value for infection, sensitivity was 73%; specificity, 67%; positive predictive value, 10%; and negative predictive value, 98%. Intrarater agreement for thermography was ICC 0.85 (0.77–0.92). The temperature measured was influenced by the camera positioning in relation to the pin site with a variance of 0.2. CONCLUSIONS: Measurements of pin site temperature using the hand-held FLIR C3 infrared camera was a reliable method and the temperature was related to infection grading. CLINICAL SIGNIFICANCE: This study demonstrated that digital thermography with a hand-held camera might be used for monitoring the pin sites after operations to detect early infection. HOW TO CITE THIS ARTICLE: Rahbek O, Husum HC, Fridberg M, et al. Intrarater Reliability of Digital Thermography in Detecting Pin Site Infection: A Proof of Concept Study. Strategies Trauma Limb Reconstr 2021;16(1):1–7
    • …
    corecore