2 research outputs found

    Circulating Cardiac Troponin T Exhibits a Diurnal Rhythm

    Get PDF
    ObjectivesThe goal of this study was to test the unverified assumption that chronically elevated cardiac troponin T (cTnT) levels fluctuate randomly around a homeostatic set point.BackgroundThe introduction of high-sensitivity cardiac troponin (cTn) assays has improved sensitivity for acute myocardial infarction (AMI). However, many patients with a single positive cTn test result do not have AMI. Therefore, the diagnosis of AMI relies strongly on serial testing and interpretation of cTn kinetics. Essential in this regard is a profound understanding of the biological variation of cTn.MethodsTwo studies were conducted to assess biological cTnT variation and to investigate the presence of a diurnal rhythm of cTnT. Study 1 comprised 23 male subjects with type 2 diabetes, with no acute cardiovascular disease. Serial venous blood samples were drawn over an 11-h period (8:30 am to 7:30 pm). In study 2, the presence of a diurnal cTnT rhythm was investigated by hourly sampling of 7 subjects from study 1 over 25 h.ResultsIn study 1, we observed a gradual decrease in cTnT concentrations during the day (24 ± 2%). This decrease was present in all participants and was most prominent in subjects with the highest baseline cTnT values (Pearson’s R 0.93). Diurnal variation of cTnT, as assessed in study 2, was characterized by peak concentrations during morning hours (8:30 am, 17.1 ± 2.9 ng/l), gradually decreasing values during daytime (8:30 pm, 11.9 ± 1.6 ng/l), and rising concentrations during nighttime (8:30 am the next day, 16.9 ± 2.8 ng/l).ConclusionsA diurnal cTnT rhythm substantiates the recommendation that all dynamic changes in cTnT should be interpreted in relation to the clinical presentation. Epidemiological studies and risk-stratification protocols with the use of cTnT may benefit from standardized sampling times. (Exercise and Glycemic Control in Type 2 Diabetes; NCT00945165

    Clinical interpretation of prostate-specific antigen values: type of applied cut-off value exceeds methods bias as the major source of variation

    No full text
    Background: Prostate-specific antigen is the biochemical gold standard for the (early) detection and monitoring of prostate cancer. Interpretation of prostate-specific antigen is both dependent on the method and cut-off. The aim of this study was to examine the effect of method-specific differences and cut-off values in a national external quality assessment scheme (EQAS). Methods: The Dutch EQAS for prostate-specific antigen comprised an annual distribution of 12 control materials. The results of two distributions were combined with the corresponding cut-off value. Differences between methods were quantified by simple linear regression based on the all laboratory trimmed mean. To assess the clinical consequence of method-specific differences and cut-off values, a clinical data-set of 1040 patients with an initial prostate-specific antigen measurement and concomitant conclusive prostate biopsy was retrospectively collected. Sensitivity and specificity for prostate cancer were calculated for all EQAS participants individually. Results: In the Netherlands, seven different prostate-specific antigen methods are used. Interestingly, 67% of these laboratories apply age-specific cut-off values. Methods showed a maximal relative difference of 26%, which were not reflected in the cut-off values. The largest differences were caused by the type of cut-off, for example in the Roche group the cut-off value differed maximal 217%. Clinically, a fixed prostate-specific antigen cut-off has a higher sensitivity than an age-specific cut-off (mean 89% range 86–93% versus 79% range 63–95%, respectively). Conclusions: This study shows that the differences in cut-off values exceed the method-specific differences. These results emphasize the need for (inter)national harmonization/standardization programmes including cut-off values to allow for laboratory-independent clinical decision-making
    corecore