22 research outputs found
The Migration and Wear of Reverse Total Shoulder Arthroplasty
Reverse total shoulder arthroplasty (RTSA) inverts the ball and socket geometry of the shoulder. Though projected to become the most common shoulder replacement in the next decade, RTSA suffers from a high complication and revision rate, with implant loosening requiring revision. As the number of indications and demand from younger patients for RTSA continues to grow, there is the need to identify implant fixation techniques that promote longevity.
Radiostereometric analysis (RSA) is the current standard for measuring implant migration, which, if continuous in the first year postoperatively is highly predictive of later loosening and failure. RSA has also been used to measure polyethylene wear, known to contribute to implant loosening through periprosthetic bone resorption. The objectives of this thesis were to compare early implant migration between different RTSA fixation techniques, and to assess the in vivo polyethylene wear rate of RTSA at mid-to-long-term follow-up.
To accomplish these objectives, the use of RSA for RTSA was first validated using a phantom setup. Subsequently, patients were prospectively randomized to compare cemented to press-fit humeral stems, and bone graft to porous metal-augmented glenosphere baseplates. Imaging was acquired postoperatively through one year. Separately, patients with an implant term-of-service greater than five years were recruited and imaged at a single timepoint. All migration analyses were performed in model-based RSA, with the addition of an in-house software for wear analysis.
Significantly greater migration was observed with press-fit compared to cemented stems six months and one year postoperatively, though both groups demonstrated stability from six months onward. There were no differences at any time point between glenosphere lateralization groups. Polyethylene wear was measurable and multidirectional, with values comparable to simulation studies.
The primary contribution of this work is the first-ever clinical RSA for RTSA study, the results of which provide the best possible evidence on the predicted longevity of cemented vs. press-fit humeral fixation, and bony vs. porous metal glenosphere lateralization. The secondary contribution is the first evaluation of in vivo RTSA polyethylene wear; the results from both studies influencing clinical care and the design of next-generation shoulder implants
Sensory ways to indigenous multimodal literacies : Hands and feet tell the story
This chapter reports original research that asks the question: What are the ways of knowing, being, and communicating that are valued and practiced in Indigenous communities? Literacy curricula, internationally and nationally, typically do not take into account the multi-sensorial dimensions of non-Western forms of representation that go beyond narrow conceptions of print. For example, literacies are often conceived as drawing on print, visual, spatial, gestural, and audio modes, but the role of haptics and locomotion has typically received little attention. This chapter highlights examples of the multi-sensoriality of Indigenous literacies observed in participatory community research with an Indigenous school. It extends recent theories of sensory studies in the history and cultural anthropology of the senses, applying these principles to literacy education. Sensory literacies is a theoretical perspective that gives priority to the sensorial dimensions of the body and its role in communication in literacy practice, because without a sensing body, we cannot know about or communicate with the world. The data demonstrates how the forgotten role of the hands and feet in dominant theories of communication is central to Indigenous identity and literacies. Written by a white academic with an Indigenous researcher, the chapter problematises the privileging of narrow, logocentric, and Western forms of literacy and its implications for rethinking the role of the whole body in literacy and the literacy curriculum for Indigenous students
Impact of renal impairment on atrial fibrillation: ESC-EHRA EORP-AF Long-Term General Registry
Background: Atrial fibrillation (AF) and renal impairment share a bidirectional relationship with important pathophysiological interactions. We evaluated the impact of renal impairment in a contemporary cohort of patients with AF. Methods: We utilised the ESC-EHRA EORP-AF Long-Term General Registry. Outcomes were analysed according to renal function by CKD-EPI equation. The primary endpoint was a composite of thromboembolism, major bleeding, acute coronary syndrome and all-cause death. Secondary endpoints were each of these separately including ischaemic stroke, haemorrhagic event, intracranial haemorrhage, cardiovascular death and hospital admission. Results: A total of 9306 patients were included. The distribution of patients with no, mild, moderate and severe renal impairment at baseline were 16.9%, 49.3%, 30% and 3.8%, respectively. AF patients with impaired renal function were older, more likely to be females, had worse cardiac imaging parameters and multiple comorbidities. Among patients with an indication for anticoagulation, prescription of these agents was reduced in those with severe renal impairment, p <.001. Over 24 months, impaired renal function was associated with significantly greater incidence of the primary composite outcome and all secondary outcomes. Multivariable Cox regression analysis demonstrated an inverse relationship between eGFR and the primary outcome (HR 1.07 [95% CI, 1.01â1.14] per 10 ml/min/1.73 m2 decrease), that was most notable in patients with eGFR <30 ml/min/1.73 m2 (HR 2.21 [95% CI, 1.23â3.99] compared to eGFR â„90 ml/min/1.73 m2). Conclusion: A significant proportion of patients with AF suffer from concomitant renal impairment which impacts their overall management. Furthermore, renal impairment is an independent predictor of major adverse events including thromboembolism, major bleeding, acute coronary syndrome and all-cause death in patients with AF
Clinical complexity and impact of the ABC (Atrial fibrillation Better Care) pathway in patients with atrial fibrillation: a report from the ESC-EHRA EURObservational Research Programme in AF General Long-Term Registry
Background: Clinical complexity is increasingly prevalent among patients with atrial fibrillation (AF). The âAtrial fibrillation Better Careâ (ABC) pathway approach has been proposed to streamline a more holistic and integrated approach to AF care; however, there are limited data on its usefulness among clinically complex patients. We aim to determine the impact of ABC pathway in a contemporary cohort of clinically complex AF patients. Methods: From the ESC-EHRA EORP-AF General Long-Term Registry, we analysed clinically complex AF patients, defined as the presence of frailty, multimorbidity and/or polypharmacy. A K-medoids cluster analysis was performed to identify different groups of clinical complexity. The impact of an ABC-adherent approach on major outcomes was analysed through Cox-regression analyses and delay of event (DoE) analyses. Results: Among 9966 AF patients included, 8289 (83.1%) were clinically complex. Adherence to the ABC pathway in the clinically complex group reduced the risk of all-cause death (adjusted HR [aHR]: 0.72, 95%CI 0.58â0.91), major adverse cardiovascular events (MACEs; aHR: 0.68, 95%CI 0.52â0.87) and composite outcome (aHR: 0.70, 95%CI: 0.58â0.85). Adherence to the ABC pathway was associated with a significant reduction in the risk of death (aHR: 0.74, 95%CI 0.56â0.98) and composite outcome (aHR: 0.76, 95%CI 0.60â0.96) also in the high-complexity cluster; similar trends were observed for MACEs. In DoE analyses, an ABC-adherent approach resulted in significant gains in event-free survival for all the outcomes investigated in clinically complex patients. Based on absolute risk reduction at 1 year of follow-up, the number needed to treat for ABC pathway adherence was 24 for all-cause death, 31 for MACEs and 20 for the composite outcome. Conclusions: An ABC-adherent approach reduces the risk of major outcomes in clinically complex AF patients. Ensuring adherence to the ABC pathway is essential to improve clinical outcomes among clinically complex AF patients
Impact of clinical phenotypes on management and outcomes in European atrial fibrillation patients: a report from the ESC-EHRA EURObservational Research Programme in AF (EORP-AF) General Long-Term Registry
Background: Epidemiological studies in atrial fibrillation (AF) illustrate that clinical complexity increase the risk of major adverse outcomes. We aimed to describe European AF patients\u2019 clinical phenotypes and analyse the differential clinical course. Methods: We performed a hierarchical cluster analysis based on Ward\u2019s Method and Squared Euclidean Distance using 22 clinical binary variables, identifying the optimal number of clusters. We investigated differences in clinical management, use of healthcare resources and outcomes in a cohort of European AF patients from a Europe-wide observational registry. Results: A total of 9363 were available for this analysis. We identified three clusters: Cluster 1 (n = 3634; 38.8%) characterized by older patients and prevalent non-cardiac comorbidities; Cluster 2 (n = 2774; 29.6%) characterized by younger patients with low prevalence of comorbidities; Cluster 3 (n = 2955;31.6%) characterized by patients\u2019 prevalent cardiovascular risk factors/comorbidities. Over a mean follow-up of 22.5 months, Cluster 3 had the highest rate of cardiovascular events, all-cause death, and the composite outcome (combining the previous two) compared to Cluster 1 and Cluster 2 (all P <.001). An adjusted Cox regression showed that compared to Cluster 2, Cluster 3 (hazard ratio (HR) 2.87, 95% confidence interval (CI) 2.27\u20133.62; HR 3.42, 95%CI 2.72\u20134.31; HR 2.79, 95%CI 2.32\u20133.35), and Cluster 1 (HR 1.88, 95%CI 1.48\u20132.38; HR 2.50, 95%CI 1.98\u20133.15; HR 2.09, 95%CI 1.74\u20132.51) reported a higher risk for the three outcomes respectively. Conclusions: In European AF patients, three main clusters were identified, differentiated by differential presence of comorbidities. Both non-cardiac and cardiac comorbidities clusters were found to be associated with an increased risk of major adverse outcomes
Additively manufactured implant components for imaging validation studies
© 2018, IMechE 2018. Radiographic imaging is the current standard for evaluating postoperative joint replacements. Prior to application, such imaging methods need to be validated to determine the lower limits of performance under ideal conditions, using either a phantom or cadaver setup. Conventionally manufactured orthopedic implants for use in such studies are not always accessible and may be cost-prohibitive to purchase. We propose the use of additively manufactured implants as a cheaper, more accessible alternative for use in radiographic imaging validation studies. Bias and repeatability were compared between conventionally manufactured and additively manufactured reverse total shoulder implant sets under a standard model-based radiostereometric analysis phantom study environment. Measurements were compared using the humeral stem or glenosphere model relative to reference bone beads, and the humeral stem relative to the glenosphere model to measure implant relative displacement. Compared to the conventionally manufactured implants, the additively manufactured implants had less bias along the internalâexternal rotation axis (p \u3c 0.001), but greater bias along the abductionâadduction and flexionâextension rotation axes (p = 0.005, 0.011). Additively manufactured implants had greater repeatability along the internalâexternal rotation axis (p \u3c 0.001), but worse repeatability along the medialâlateral translation axis (p = 0.001) and the abductionâadduction rotation axis (p \u3c 0.001). Differences were on the orders of 0.01 mm and 0.5°. For the purpose of validating two-dimensionalâthree-dimensional radiographic imaging techniques of orthopedic implants, additively manufactured implants can be used in place of conventionally manufactured implants, assuming they are fabricated to the manufacturerâs specifications. Observed differences were within the errors of the measurement technique and not clinically meaningful
Validation of In Vivo Linear and Volumetric Wear Measurement for Reverse Total Shoulder Arthroplasty Using Model-Based Radiostereometric Analysis
© 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. Presently, polyethylene wear measurement of reverse total shoulder arthroplasty (rTSA) is restricted to in vitro, in silico, and retrieval analysis, with no method for the quantification of in vivo wear of well-functioning implants. The purpose of this study was to validate the use of model-based radiostereometric analysis (MBRSA) as a measurement tool for in vivo rTSA wear using a phantom setup. Six additively manufactured polyethylene inserts were fabricated, one unworn control and five to represent known wear patterns, and individually fit within the rTSA components. Each insert was imaged using standard radiostereometric techniques and analyzed using MBRSA. From the position and orientation estimation provided by MBRSA, a micro-computed tomography model of the control insert was virtually placed within the metaphyseal tray. The apparent intersection of the glenosphere into the insert was recorded as wear. This method enables wear measurements with a linear precision of 0.21 mm and a bias of 0.36 ± 0.13 mm, and a volumetric precision of 49.3 mm3, with a bias of 48.9 ± 24.3 mm3. This technique allows for the in vivo measurement of polyethylene wear without the requirement of marker beads or baseline radiographs, expanding the potential for in vivo wear measurements to larger populations and retrospective analysis. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:1620â1627, 2019
Validation of radiostereometric analysis in six degrees of freedom for use with reverse total shoulder arthroplasty
© 2017 Elsevier Ltd A phantom study was conducted to determine bias in motion and bias at zero motion of radiostereometric analysis (RSA) for evaluating implant relative displacement in reverse total shoulder arthroplasty (RTSA). A Sawbones shoulder phantom was fitted with a RTSA implant set and 13 tantalum markers. The model was fixed to a manual micrometer, providing controlled movements though fifteen known increments in translation and twelve increments in rotation (0.02â5.00 mm and 0.1â6.0°), along each translation and rotation axis. Movement between the glenoid and humerus was assessed using beads vs. beads (B/B), model vs. beads (M/B), and model vs. model (M/M) measurement methods in a model-based RSA environment. Bias in motion and bias at zero motion were defined as the difference between measured and accepted reference values, and the difference between double examinations with a theoretical displacement of zero, respectively. Bias in motion ranged from 0.054 ± 0.010 to 0.129 ± 0.014 mm and 0.076 ± 0.025 to 0.126 ± 0.025° (B/B), 0.023 ± 0.009 to 0.126 ± 0.016 mm and 0.111 ± 0.033 to 0.794 ± 0.251° (M/B), and 0.029 ± 0.010 to 0.135 ± 0.030 mm and 0.243 ± 0.088 to 0.384 ± 0.153° (M/M). Bias at zero motion ranged from 0.120 to 0.156 mm and 0.075 to 0.206° (B/B), 0.074 to 0.149 mm and 0.067 to 1.953° (M/B), and 0.069 to 0.259 mm and 0.284 to 1.273° (M/M). This is the first RSA for RTSA study, with results comparable to those validating the use of RSA for hip and knee arthroplasties (accepted as 0.05â0.50 mm and 0.15â1.15°), justifying the potential use of RSA as a tool for measuring implant displacement in the shoulder
In vivo volumetric and linear wear measurement of reverse shoulder arthroplasty at minimum 5-year follow-up
© 2020 Background: Reverse shoulder arthroplasty is quickly becoming the most frequently performed glenohumeral joint replacement. The purpose of this study was to evaluate the volumetric and linear wear rates of ultrahigh-molecular-weight polyethylene humeral liners in vivo at a minimum 5-year follow-up. Methods: Radiostereometric analysis was used to image 15 patients at terminal range of motion in forward flexion, abduction, external rotation, and internal rotation and with the arm at the side. The relative position and orientation of the glenosphere and polyethylene were identified for each arm position. The apparent intersection of the glenosphere into the polyethylene was recorded as wear. Mean volumetric and linear wear rates were recorded, and Pearson correlation coefficients were applied to the 36-mm liners to assess the relationship between the wear rate and term of service. Results: The mean reverse shoulder arthroplasty term of service at the time of imaging was 8 ± 1 years (range, 6-11 years). The mean volumetric and linear wear rates for the 36-mm liners (n = 13) were 42 ± 22 mm3/yr (r = 0.688, P =.009) and 0.11 ± 0.03 mm/yr (r = 0.767, P =.002), respectively. The mean volumetric and linear wear rates for the 42-mm liners (n = 2) were 114 ± 44 mm3/yr and 0.17 ± 0.01 mm/yr, respectively. No single arm position was able to capture all recorded wear individually. Conclusion: This study showed volumetric and linear wear rates of approximately 40 mm3/yr and 0.1 mm/yr, respectively, for the 36-mm polyethylene liners. The 42-mm liners showed higher wear rates, although a greater number of subjects is required for conclusive results. In vivo wear of reverse total shoulder arthroplasty is multidirectional and perceptible