3 research outputs found

    Patients with acute coronary syndromes without persistent ST elevation undergoing percutaneous coronary intervention benefit most from early intervention with protection by a glycoprotein IIb/IIIa receptor blocker.

    Get PDF
    BACKGROUND: Many patients with acute coronary syndromes are offered percutaneous coronary intervention. However, the appropriate indications for, and optimal timing of, such procedures are uncertain. We analysed timing of intervention and associated events (death and myocardial infarction) in the PURSUIT trial in which 9461 patients received a platelet glycoprotein IIb/IIIa inhibitor, eptifibatide, or placebo for 72 h. Other treatment was left to the investigators. 2430 patients underwent percutaneous coronary intervention within 30 days. Four groups were distinguished, who underwent percutaneous coronary intervention on day 1; on days 2 or 3; at 4 to 7 days; or between 8 until 30 days, for eptifibatide- and placebo-treated patients. RESULTS: The four groups treated with placebo demonstrated total 30-

    Early percutaneous coronary intervention, platelet inhibition with eptifibatide, and clinical outcomes in patients with acute coronary syndromes. PURSUIT Investigators

    No full text
    BACKGROUND: Platelet glycoprotein (GP) IIb/IIIa antagonists prevent the composite end point of death or myocardial infarction (MI) in patients with acute coronary syndromes. There is uncertainty about whether this effect is confined to patients who have percutaneous coronary interventions (PCIs) and whether PCIs further prevent death or MI in patients already treated with GP IIb/IIIa antagonists. METHODS AND RESULTS: PURSUIT patients were treated with the GP IIb/IIIa antagonist eptifibatide or placebo; PCIs were performed according to physician practices. In 2253 of 9641 patients (23.4%), PCI was performed by 30 days. Early (<72 hours) PCI was performed in 1228 (12.7%). In 34 placebo patients (5.5%) and 10 treated with eptifibatide (1.7%) (P=0.001), MI preceded early PCI. In patients censored for PCI across the 30-day period, there was a significant reduction in the primary composite end point in eptifibatide patients (P=0.035). Eptifibatide reduced 30-day events in patients who had early PCI (11.6% versus 16.7%, P=0.01) and in patients who did not (14.6% versus 15.6%, P=0.23). After adjustment for PCI propensity, there was no evidence that eptifibatide treatment effect differed between patients with or without early PCI (P for interaction=0.634). PCI was not associated with a reduction of the primary composite end point but was associated with a reduced (nonspecified) composite of death or Q-wave MI. This association disappeared after adjustment for propensity for early PCI. CONCLUSIONS: Eptifibatide reduced the composite rates of death or MI in PCI patients and those managed conservatively

    Health status after transcatheter aortic valve replacement in patients at extreme surgical risk: Results from the CoreValve U.S. Trial

    Get PDF
    Objectives The purpose of this study was to characterize health status outcomes after transcatheter aortic valve replacement (TAVR) with a self-expanding bioprosthesis among patients at extreme surgical risk and to identify pre-procedural patient characteristics associated with a poor outcome. Background For many patients considering TAVR, improvement in quality of life may be of even greater importance than prolonged survival. Methods Patients with severe, symptomatic aortic stenosis who were considered to be at prohibitive risk for surgical aortic valve replacement were enrolled in the single-arm CoreValve U.S. Extreme Risk Study. Health status was assessed at baseline and at 1, 6, and 12 months after TAVR using the Kansas City Cardiomyopathy Questionnaire (KCCQ), the Short Form-12, and the EuroQol-5D. The overall summary scale of the KCCQ (range 0 to 100; higher scores = better health) was the primary health status outcome. A poor outcome after TAVR was defined as death, a KCCQ overall summary score (OS) <45, or a decline in KCCQ-OS of 10 points at 6-month follow-up. Results A total of 471 patients underwent TAVR via the transfemoral approach, of whom 436 (93%) completed the baseline health status survey. All health status measures demonstrated considerable impairment at baseline. After TAVR, there was substantial improvement in both disease-specific and generic health status measures, with an increase in the KCCQ-OS of 23.9 points (95% confidence interval [CI]: 20.3 to 27.5 points) at 1 month, 27.4 points (95% CI: 24.2 to 30.6 points) at 6 months, 27.4 points (95% CI: 24.1 to 30.8 points) at 12 months, along with substantial increases in Short Form-12 scores and EuroQol-5D utilities (all p < 0.003 compared with baseline). Nonetheless, 39% of patients had a poor outcome after TAVR. Baseline factors independently associated with poor outcome included wheelchair dependency, lower mean aortic valve gradient, prior coronary artery bypass grafting, oxygen dependency, very high predicted mortality with surgical aortic valve replacement, and low serum albumin. Conclusions Among patients with severe aortic stenosis, TAVR with a self-expanding bioprosthesis resulted in substantial improvements in both disease-specific and generic health-related quality of life, but there remained a large minority of patients who died or had very poor quality of life despite TAVR. Predictive models based on a combination of clinical factors as well as disability and frailty may provide insight into the optimal patient population for whom TAVR is beneficial. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902
    corecore