    Catheter ablation of atrial fibrillation : radiofrequency catheter ablation for redo procedures after cryoablation

    Get PDF
    Aim: To evaluate the effectiveness of two different strategies using radiofrequency catheter ablation for redo procedures after cryoablation of atrial fibrillation. Methods: Thirty patients (paroxysmal atrial fibrillation: 22 patients, persistent atrial fibrillation: 8 patients) had to undergo a redo procedure after initially successful circumferential pulmonary vein (PV) isolation with the cryoballoon technique (Arctic Front Balloon, CryoCath Technologies/Medtronic). The redo ablation procedures were performed using a segmental approach or a circumferential ablation strategy (CARTO; Biosense Webster) depending on the intra-procedural findings. After discharge, patients were scheduled for repeated visits at the arrhythmia clinic. A 7-day Holter monitoring was performed at 3, 12 and 24 mo after the ablation procedure. Results: During the redo procedure, a mean number of 2.9 re-conducting pulmonary veins (SD ± 1.0 PVs) were detected (using a circular mapping catheter). In 20 patients, a segmental approach was sufficient to eliminate the residual pulmonary vein conduction because there were only a few recovered pulmonary vein fibres. In the remaining 10 patients, a circumferential ablation strategy was used because of a complete recovery of the PV-LA conduction. All recovered pulmonary veins could be isolated successfully again. At 2-year follow-up, 73.3% of all patients were free from an arrhythmia recurrence (22/30). There were no major complications. Conclusion: In patients with an initial circumferential pulmonary vein isolation using the cryoballoon technique, a repeat ablation procedure can be performed safely and effectively using radiofrequency catheter ablation

    Catheter ablation of atrial fibrillation facilitated by preprocedural three-dimensional transesophageal echocardiography : long-term outcome

    No full text
    Aim: To evaluate the long-term outcome of catheter ablation of atrial fibrillation (AF) facilitated by preprocedural three-dimensional (3-D) transesophageal echocardiography. Methods: In 50 patients, 3D transesophageal echocardiography (3D TEE) was performed immediately prior to an ablation procedure (paroxysmal AF: 30 patients, persistent AF: 20 patients). The images were available throughout the ablation procedure. Two different ablation strategies were used. In most of the patients with paroxysmal AF, the cryoablation technique was used (Arctic Front Balloon, CryoCath Technologies/Medtronic; group A2). In the other patients, a circumferential pulmonary vein ablation was performed using the CARTO system [Biosense Webster; group A1 (paroxysmal AF), group B (persistent AF)]. Success rates and complication rates were analysed at 4-year follow-up. Results: A 3D TEE could be performed successfully in all patients prior to the ablation procedure and all four pulmonary vein ostia could be evaluated in 84% of patients. The image quality was excellent in the majority of patients and several variations of the pulmonary vein anatomy could be visualized precisely (e.g., common pulmonary vein ostia, accessory pulmonary veins, varying diameter of the left atrial appendage and its distance to the left superior pulmonary vein). All ablation procedures could be performed as planned and almost all pulmonary veins could be isolated successfully. At 48-mo follow-up, 68.0% of all patients were free from an arrhythmia recurrence (group A1: 72.7%, group A2: 73.7%, group B: 60.0%). There were no major complications. Conclusion: 3D TEE provides an excellent overview over the left atrial anatomy prior to AF ablation procedures and these procedures are associated with a favourable long-term outcome
    corecore