Current Practice of Heart Donor Evaluation in Germany: Multivariable Risk Factor Analysis Confirms Practicability of Guidelines
Background. Organ shortage has liberalised the acceptance criteria of grafts for heart transplantation, but which donor characteristics ultimately influence the decision to perform transplantation? For the first time this was evaluated using real-time donor data from the German organ procurement organization (DSO). Observed associations are discussed with regard to international recommendations and guidelines. Methods. 5291 German donors (2006–2010) were formally eligible for heart donation. In logistic regression models 160 donor parameters were evaluated to assess their influence on using grafts for transplantation (random split of cases: 2/3 study sample, 1/3 validation sample). Results. Successful procurement was determined by low donor age (OR 0.87 per year; 95% CI [0.85–0.89], P<0.0001), large donor height (OR 1.04 per cm; 95% CI [1.02–1.06], P<0.0001), exclusion of impaired left ventricular function or wall motion (OR 0.01; 95% CI [0.002–0.036], P<0.0001), arrhythmia (OR 0.05; 95% CI [0.009–0.260], P=0.0004), and of severe coronary artery disease (OR 0.003; 95% CI [<0.001–0.01], P<0.0001). Donor characteristics differed between cases where the procedure was aborted without and with allocation initiated via Eurotransplant
Machine perfusion versus cold storage for preservation of kidneys from expanded criteria donors after brain death
P>The purpose of this study was to analyze the possible effects of machine perfusion (MP) versus cold storage (CS) on delayed graft function (DGF) and early graft survival in expanded criteria donor kidneys (ECD). As part of the previously reported international randomized controlled trial 91 consecutive heart-beating deceased ECDs - defined according to the United Network of Organ Sharing definition - were included in the study. From each donor one kidney was randomized to MP and the contralateral kidney to CS. All recipients were followed for 1 year. The primary endpoint was DGF. Secondary endpoints included primary nonfunction and graft survival. DGF occurred in 27 patients in the CS group (29.7%) and in 20 patients in the MP group (22%). Using the logistic regression model MP significantly reduced the risk of DGF compared with CS (OR 0.460, P = 0.047). The incidence of nonfunction in the CS group (12%) was four times higher than in the MP group (3%) (P = 0.04). One-year graft survival was significantly higher in machine perfused kidneys compared with cold stored kidneys (92.3% vs. 80.2%, P = 0.02). In the present study, MP preservation clearly reduced the risk of DGF and improved 1-year graft survival and function in ECD kidneys. (Current Controlled Trials number: ISRCTN83876362)
Machine Perfusion or Cold Storage in Deceased-Donor Kidney Transplantation
BACKGROUND Static cold storage is generally used to preserve kidney allografts from deceased donors. Hypothermic machine perfusion may improve outcomes after transplantation, but few sufficiently powered prospective studies have addressed this possibility. METHODS In this international randomized, controlled trial, we randomly assigned one kidney from 336 consecutive deceased donors to machine perfusion and the other to cold storage. All 672 recipients were followed for 1 year. The primary end point was delayed graft function ( requiring dialysis in the first week after transplantation). Secondary end points were the duration of delayed graft function, delayed graft function defined by the rate of the decrease in the serum creatinine level, primary nonfunction, the serum creatinine level and clearance, acute rejection, toxicity of the calcineurin inhibitor, the length of hospital stay, and allograft and patient survival. RESULTS Machine perfusion significantly reduced the risk of delayed graft function. Delayed graft function developed in 70 patients in the machine- perfusion group versus 89 in the cold- storage group ( adjusted odds ratio, 0.57; P = 0.01). Machine perfusion also significantly improved the rate of the decrease in the serum creatinine level and reduced the duration of delayed graft function. Machine perfusion was associated with lower serum creatinine levels during the first 2 weeks after transplantation and a reduced risk of graft failure ( hazard ratio, 0.52; P = 0.03). One- year allograft survival was superior in the machine- perfusion group ( 94% vs. 90%, P = 0.04). No significant differences were observed for the other secondary end points. No serious adverse events were directly attributable to machine perfusion. CONCLUSIONS Hypothermic machine perfusion was associated with a reduced risk of delayed graft function and improved graft survival in the first year after transplantation. (Current Controlled Trials number, ISRCTN83876362.)