385 research outputs found

    Flow rate accuracy of infusion devices within healthcare settings: a systematic review

    Get PDF
    Background: One in five patients admitted to the hospital treated with intravenous (IV) fluid therapy suffer complications due to inappropriate administration. Errors have been reported in 13-84% of the preparation and administration of IV medications. The safe delivery of IV fluids requires precise rate administration. Objectives: This systematic review aims to determine the accuracy of infusion sets and devices and examine the factors that affect the flow rate accuracy of devices. Data sources and methods: Six databases (CINAHL, MEDLINE PubMed, EMBASE, Web of Science and Cochrane Database of systematic reviews) were systematically searched. Search terms included infusion pumps, infusion devices, flow rate accuracy, fluid administration rate, gravity-led infusion set and fluid balance. Studies were included if they examined infusion devices' flow rate accuracy and drop rates for fluids or non-oncological drugs. Findings were tabulated and synthesised qualitatively. The quality of the studies was examined based on the design of the studies due to their heterogeneity. Results: Eight studies were included: Four studies were conducted on human subjects in the hospital environment; studies recruited 182 participants between the ages of 18 and 94 years. Two studies examined flow rate accuracy in recruited patients across 509 observations and 2387 drip hours. No trials prospectively assessed the accuracy of infusion pumps in the clinical domain, and no studies were reported on patient safety outcomes. Four studies examined the impact of mechanical and physiological factors on the flow rate accuracies of infusion devices. Height and back pressure simulated vibrating conditions, the viscosity of IV fluid and the positions of patients were reported to have a significant impact on infusion volume and flow rates of infusion devices. Additionally, giving sets that vary from the manufacturer's specifications are reported to increase error percent by 10-20%. Conclusion: Infusion devices are an important source of error in administering IV fluids. Yet, there needs to be more prospective trial data to support their clinical accuracy and the impact on patient outcomes. Future flow variability and accuracy studies should capture their impact on patient safety and clinical outcomes

    Can mixed reality technologies teach surgical skills better than traditional methods? A prospective randomised feasibility study

    Get PDF
    Background Basic surgical skills teaching is often delivered with didactic audio-visual content, and new digital technologies may allow more engaging and effective ways of teaching to be developed. The Microsoft HoloLens 2 (HL2) is a multi-functional mixed reality headset. This prospective feasibility study sought to assess the device as a tool for enhancing technical surgical skills training. Methods A prospective randomised feasibility study was conducted. 36 novice medical students were trained to perform a basic arteriotomy and closure using a synthetic model. Participants were randomised to receive a structured surgical skills tutorial via a bespoke mixed reality HL2 tutorial (n = 18), or via a standard video-based tutorial (n = 18). Proficiency scores were assessed by blinded examiners using a validated objective scoring system and participant feedback collected. Results The HL2 group showed significantly greater improvement in overall technical proficiency compared to the video group (10.1 vs. 6.89, p = 0.0076), and a greater consistency in skill progression with a significantly narrower range of scores (SD 2.48 vs. 4.03, p = 0.026). Participant feedback showed the HL2 technology to be more interactive and engaging with minimal device related problems experienced. Conclusions This study has demonstrated that mixed reality technology may provide a higher quality educational experience, improved skill progression and greater consistency in learning when compared to traditional teaching methodologies for basic surgical skills. Further work is required to refine, translate, and evaluate the scalability and applicability of the technology across a broad range of skills-based disciplines

    Comparison of Accelerated Solvent Extraction (ASE) and Energized Dispersive Guided Extraction (EDGE) for the Analysis of Pesticides in Leaves

    Get PDF
    Various techniques have been evaluated for the extraction and cleanup of pesticides from environmental samples. In this work, a Selective Pressurized Liquid Extraction (SPLE) method for pesticides was developed using a Thermo Fisher Scientific Accelerated Solvent Extraction (ASE) system. This instrument was compared to the newly introduced (2017) extraction instrument, the Energized Dispersive Guided Extraction (EDGE) system, which combines Pressurized Liquid Extraction (PLE) and dispersive Solid Phase Extraction (dSPE). We first optimized the SPLE method using the ASE instrument for pesticide extraction from alfalfa leaves using layers of Florisil and graphitized carbon black (GCB) downstream of the leaf homogenate in the extraction cell (Layered ASE method). We then compared results obtained for alfalfa and citrus leaves with the Layered ASE method to those from a method in which the leaf homogenate and sorbents were mixed (Mixed ASE method) and to similar methods modified for use with EDGE (Layered EDGE and Mixed EDGE methods). The ASE and EDGE methods led to clear, colorless extracts with low residual lipid weight. No significant differences in residual lipid masses were observed between the methods. The UV-Vis spectra showed that Florisil removed a significant quantity of the light-absorbing chemicals, but that GCB was required to produce colorless extracts. Recoveries of spiked analytes into leaf homogenates were generally similar among methods, but in several cases, significantly higher recoveries were observed in ASE extracts. Nonetheless, no significant differences were observed among pesticide concentrations in field samples when calculated with the isotope dilution method in which labelled surrogates were added to samples before extraction. The extraction time with the ASE methods was ~45 minutes, which was ~4.5 times longer than with the EDGE methods. The EDGE methods used ~10 mL more solvent than the ASE methods. Based on these results, the EDGE is an acceptable extraction instrument and, for most compounds, the EDGE had a similar extraction efficiency to the ASE methods

    A novel methodology for in vivo endoscopic phenotyping of colorectal cancer based on real-time analysis of the mucosal lipidome: a prospective observational study of the iKnife

    Get PDF
    Background: This pilot study assessed the diagnostic accuracy of rapid evaporative ionization mass spectrometry (REIMS) in colorectal cancer (CRC) and colonic adenomas. Methods: Patients undergoing elective surgical resection for CRC were recruited at St. Mary’s Hospital London and The Royal Marsden Hospital, UK. Ex vivo analysis was performed using a standard electrosurgery handpiece with aspiration of the electrosurgical aerosol to a Xevo G2-S iKnife QTof mass spectrometer (Waters Corporation). Histological examination was performed for validation purposes. Multivariate analysis was performed using principal component analysis and linear discriminant analysis in Matlab 2015a (Mathworks, Natick, MA). A modified REIMS endoscopic snare was developed (Medwork) and used prospectively in five patients to assess its feasibility during hot snare polypectomy. Results: Twenty-eight patients were recruited (12 males, median age 71, range 35–89). REIMS was able to reliably distinguish between cancer and normal adjacent mucosa (NAM) (AUC 0.96) and between NAM and adenoma (AUC 0.99). It had an overall accuracy of 94.4 % for the detection of cancer versus adenoma and an adenoma sensitivity of 78.6 % and specificity of 97.3 % (AUC 0.99) versus cancer. Long-chain phosphatidylserines (e.g., PS 22:0) and bacterial phosphatidylglycerols were over-expressed on cancer samples, while NAM was defined by raised plasmalogens and triacylglycerols expression and adenomas demonstrated an over-expression of ceramides. REIMS was able to classify samples according to tumor differentiation, tumor budding, lymphovascular invasion, extramural vascular invasion and lymph node micrometastases (AUC’s 0.88, 0.87, 0.83, 0.81 and 0.81, respectively). During endoscopic deployment, colonoscopic REIMS was able to detect target lipid species such as ceramides during hot snare polypectomy. Conclusion: REIMS demonstrates high diagnostic accuracy for tumor type and for established histological features of poor prognostic outcome in CRC based on a multivariate analysis of the mucosal lipidome. REIMS could augment endoscopic and imaging technologies for precision phenotyping of colorectal cancer

    The use of mixed reality technology for the objective assessment of clinical skills: a validation study

    Get PDF
    Background Mixed Reality technology may provide many advantages over traditional teaching methods. Despite its potential, the technology has yet to be used for the formal assessment of clinical competency. This study sought to collect validity evidence and assess the feasibility of using the HoloLens 2 mixed reality headset for the conduct and augmentation of Objective Structured Clinical Examinations (OSCEs). Methods A prospective cohort study was conducted to compare the assessment of undergraduate medical students undertaking OSCEs via HoloLens 2 live (HLL) and recorded (HLR), and gold-standard in-person (IP) methods. An augmented mixed reality scenario was also assessed. Results 13 undergraduate participants completed a total of 65 OSCE stations. Overall inter-modality correlation was 0.81 (p=0.01), 0.98 (p=0.01) and 0.82 (p=0.01) for IP vs. HLL, HLL vs. HLR and IP vs. HLR respectively. Skill based correlations for IP vs. HLR were assessed for history taking (0.82, p=0.01), clinical examination (0.81, p=0.01), procedural (0.88, p=0.01) and clinical skills (0.92, p=0.01), and assessment of a virtual mixed reality patient (0.74, p=0.01). The HoloLens device was deemed to be usable and practical (Standard Usability Scale (SUS) score = 51.5), and the technology was thought to deliver greater flexibility and convenience, and have the potential to expand and enhance assessment opportunities. Conclusions HoloLens 2 is comparable to traditional in-person examination of undergraduate medical students for both live and recorded assessments, and therefore is a valid and robust method for objectively assessing performance. The technology is in its infancy, and users need to develop confidence in its usability and reliability as an assessment tool. However, the potential to integrate additional functionality including holographic content, automated tracking and data analysis, and to facilitate remote assessment may allow the technology to enhance, expand and standardise examinations across a range of educational contexts

    Colorectal carcinogenesis: an archetype of gut microbiota-host interaction

    Get PDF
    Sporadic colorectal cancer (CRC) remains a major cause of worldwide mortality. Epidemiological evidence of markedly increased risk in populations that migrate to Western countries, or adopt their lifestyle, suggests that CRC is a disease whose aetiology is defined primarily by interactions between the host and his environment. The gut microbiome sits directly at this interface and is now increasingly recognised as a modulator of colorectal carcinogenesis. Bacteria such as Fusobacterium nucleatum and Escherichia coli (E. Coli) are found in abundance in patients with CRC and have been shown in experimental studies to promote neoplasia. A whole armamentarium of bacteria-derived oncogenic mechanisms has been defined, including the subversion of apoptosis and the production of genotoxins and pro-inflammatory factors. But the microbiota may also be protective: for example, they are implicated in the metabolism of dietary fibre to produce butyrate, a short chain fatty acid, which is anti-inflammatory and anti-carcinogenic. Indeed, although our understanding of this immensely complex, highly individualised and multi-faceted relationship is expanding rapidly, many questions remain: Can we define friends and foes, and drivers and passengers? What are the critical functions of the microbiota in the context of colorectal neoplasia

    Electrocautery, diathermy, and surgical energy devices: are surgical teams at risk during the COVID-19 pandemic?

    Get PDF
    OBJECTIVE: The aim of the study was to provide a rapid synthesis of available data to identify the risk posed by utilizing surgical energy devices intraoperatively due to the generation of surgical smoke, an aerosol. Secondarily it aims to summarize methods to minimize potential risk to operating room staff. SUMMARY BACKGROUND DATA: Continuing operative practice during the coronavirus disease-19 (COVID-19) pandemic places the health of operating theatre staff at potential risk. SARS-CoV2 is transmitted through inhaled droplets and aerosol particles, thus posing an inhalation threat even at considerable distance. Surgical energy devices generate an aerosol of biological particular matter during use. The risk to healthcare staff through use of surgical energy devices is unknown. METHODS: This review was conducted utilizing a rapid review methodology to enable efficient generation and dissemination of information useful for concurrent clinical practice. RESULTS: There are conflicting stances on the use of energy devices and laparoscopy by different surgical governing bodies and societies. There is no definitive evidence that aerosol generated by energy devices may carry active SARS-CoV2 virus. However, investigations of other viruses have demonstrated aerosolization through energy devise use. Measures to reduce potential transmission include appropriate personal protective equipment, evacuation and filtration of surgical plume, limiting energy device use if appropriate, and adjusting endoscopic and laparoscopic practice (low CO2 pressures, evacuation through ultrafiltration systems). CONCLUSIONS: The risk of transmission of SARS-CoV2 through aerosolized surgical smoke associated with energy device use is not fully understood, however transmission is biologically plausible. Caution and appropriate measures to reduce risk to healthcare staff should be implemented when considering intraoperative use of energy devices

    The use of oral antibiotics and mechanical bowel preparation in elective colorectal resection for the reduction of surgical site infection.

    Get PDF
    Surgical site infection (SSI) is a major cause of morbidity following elective colorectal resection worldwide. Reduction in SSI rates can be achieved with the use of SSI reduction bundles. Debate about the role of mechanical bowel preparation and oral antibiotics (MOAB) in reducing SSI has persisted over decades with considerable variation in international practice. This article summarises the arguments for and against the routine use of MOAB in the elective setting, highlighting the areas of controversy and evidence gaps and provides pragmatic suggestions for colorectal practice.This topical debate paper was commissioned by the President and Executive of the Association of Coloproctology of Great Britain and Ireland. ACPGBI also funded the open access publication fee. The authors would like to thank Ms J Pipe for her comments from the patient perspective and Miss N Fearnhead for her support in developing this debate article

    Molecular Rotation in 3 Dimensions at an Air/Water Interface Using Femtosecond Time Resolved Sum Frequency Generation

    Get PDF
    This paper presents the first study of the rotations of rigid molecules in 3 dimensions at the air/water interface, using the femtosecond time resolved sum frequency generation (SFG) technique. For the purpose of this research, the aromatic dye molecule C153 was chosen as an example of a molecule having two functional groups that are SFG active, one being the hydrophilic −−C==O group and the other the hydrophobic −−CF3 group. From polarized SFG measurements, the orientations of the two chromophores with respect to the surface normal were obtained. On combining these results with the known relative orientation of the two chromophores in the molecule yields the absolute orientation of C153 at the air/water interface. It was found that the −−CF3 axis projected towards the bulk air at an angle of 59○ with respect to the interface normal and the −−C==O group projected towards the bulk water at an angle of 144○ . In order to observe the rotational motions of C153 at the air/water interface, the approach was used to perturb the ground electronic state equilibrium orientational distribution using a polarized resonant pump pulse, which preferentially excites ground state molecules that have their electronic S0 → S1 transition moment aligned closely to the electric field of the incident pump pulse. As a consequence of the photoselection perturbation, the orientational distribution of the remaining ground state molecules was not the equilibrium distribution. Similarly, the orientational distribution of the excited state molecules that were created by the polarized pump pulse was not in their final equilibrium orientational distribution. The rotational motions of the interfacial molecules towards equilibrium were obtained from time dependent measurements of the intensities of the SFG signal generated by the simultaneous incidence at the air/water interface of a visible probe pulse plus an IR probe pulse. In this way, the recovery times to achieve the orientational equilibrium of the two chromophores including the orientation of the normal of the C153 plane with respect to the interface were obtained. The photo-selection process shifts the average orientation angle of the hydrophilic −−C==O group by an increase of 4○ ± 0.6○ with a rotational recovery time constant of 130 ± 20 ps, which is the time to return to an orientational equilibrium distribution. The hydrophobic –CF3 group undergoes a shift that increases its angle by 8○ ± 1.5○ with a rotational recovery time constant of 210 ± 38 ps. We find that the orientational change of the molecular normal is 4○ ± 0.5○ and has a rotational recovery time constant of 125 ± 26 ps. The interface-specific time-dependent polarized measurements allowed us to monitor the orientational motions of molecules at interfaces, both in 3 dimensions and in real time
    • …
    corecore