3 research outputs found

    COMPARISON OF NON-MAXIMAL TESTS FOR ESTIMATING EXERCISE CAPACITY

    Get PDF
    Although maximal incremental exercise tests (GXT) are the gold standard for outcome assessment and exercise prescription, they are not widely available in either fitness or clinical exercise programs. This study compared the prediction of VO2max in healthy, sedentary volunteers using a non-exercise prediction (Matthews et al., 1999), RPE extrapolation to 19 and 20 and the Rockport Walking Test (RWT), and of ventilatory threshold (VT) using the Talk Test and RPE @ 13,14,15. Subjects performed a treadmill GXT with gas exchange, a submaximal treadmill with RPE and Talk Test, the RWT and Matthews. All methods provided reasonable estimates of both VO2max and VT, with correlations of >0.80 and SEE~1.3 METs. VO2max was best estimated with the extrapolation to RPE=19. VT was intermediate between the TT Last Positive and Equivocal stages and between RPE 13 and 14. Non-maximal evaluation can be used in place of maximal GXT with gas exchange to make reasonable estimates of both VO2max and V

    Effect of Face Masks on Physiological and Perceptual Responses during 30 Minutes of Self-Paced Exercise in Older Community Dwelling Adults

    No full text
    This study examined the effects of different types of masks (no mask, surgical mask (SM), and N95-mask) on physiological and perceptual responses during 30-min of self-paced cycle ergometer exercise. This study was a prospective randomly assigned experimental design. Outcomes included workload (Watts), oxygen saturation (SpO2), end-tidal carbon dioxide (PetCO2), heart rate (HR), respiratory rate (RR), rating of perceived exertion (RPE), and rating of perceived dyspnea (RPD). Volunteers (54–83 years (n = 19)) completed two familiarization sessions and three testing sessions on an air braked cycle ergometer. No significant difference was found for condition x time for any of the dependent variables. RPE, RPD, and PetCO2 were significantly higher with an N95-mask vs. no mask (NM) ((p = 0.012), (p = 0.002), (p < 0.001)). HR was significantly higher with the SM compared to the NM condition (p = 0.027) (NM 107.18 ± 9.96) (SM 112.34 ± 10.28), but no significant difference was found when comparing the SM to the N95 condition or when comparing the N95condition to the NM condition. Watts increased across time in each condition (p = 0.003). Initially RR increased during the first 3 min of exercise (p < 0.001) with an overall gradual increase noted across time regardless of mask condition (p < 0.001). SpO2 significantly decreased across time but remained within normal limits (>95%). No significant difference was found in Watts, RR, or SpO2 regardless of mask condition. Overall, the N95mask was associated with increased RPE, RPD, and PetCO2 levels. This suggests trapping of CO2 inside the mask leading to increased RPE and RPD
    corecore