12 research outputs found

    The ACRA Anatomy Study (Assessment of Disability After Coronary Procedures Using Radial Access): A Comprehensive Anatomic and Functional Assessment of the Vasculature of the Hand and Relation to Outcome After Transradial Catheterization

    Get PDF
    BACKGROUND: The palmar arches serve as the most important conduits for digital blood supply, and incompleteness may lead to digital ischemia when the radial artery becomes obstructed after cardiac catheterization. The rate of palmar arch incompleteness and the clinical consequences after transradial access are currently unknown.METHODS AND RESULTS: The vascular anatomy of the hand was documented by angiography in 234 patients undergoing transradial cardiac catheterization. In all patients, a preprocedural modified Allen test and Barbeau test were performed. Upper-extremity function was assessed at baseline and 2-year follow-up by the QuickDASH. Incompleteness of the superficial palmar arch (SPA) was present in 46%, the deep palmar arch was complete in all patients. Modified Allen test and Barbeau test results were associated with incompleteness of the SPA (P=0.001 and P=0.001). The modified Allen test had a 33% sensitivity and 86% specificity for SPA incompleteness with a cutoff value of >10 seconds and a 59% sensitivity and 60% specificity with a cutoff value of >5 seconds. The Barbeau test had a 7% sensitivity and 98% specificity for type D and a 21% sensitivity and 93% specificity for types C and D combined. Upper-extremity dysfunction was not associated with SPA incompleteness (P=0.77).CONCLUSIONS: Although incompleteness of the SPA is common, digital blood supply is always preserved by a complete deep palmar arch. Preprocedural patency tests have thus no added benefit to prevent ischemic complications of the hand. Finally, incompleteness of the SPA is not associated with a loss of upper-extremity function after transradial catheterization

    First international new intravascular rigid-flex endovascular stent study (FINESS): Clinical and angiographic results after elective and urgent stent implantation

    Get PDF
    Objectives. The purpose of this study was to determine the feasibility, safety and efficacy of elective and urgent deployment of the new intravascular rigid-flex (NIR) stent in patients with coronary artery disease. Background. Stent implantation has been shown to be effective in the treatment of focal, new coronary stenoses and in restoring coronary flow after coronary dissection and abrupt vessel closure. However, currently available stents either lack flexibility, hindering navigation through tortuous arteries, or lack axial strength, resulting in suboptimal scaffolding of the vessel. The unique transforming multicellular design of the NIR stent appears to provide both longitudinal flexibility and radial strength. Methods. NIR stent implantation was attempted in 255 patients (341 lesions) enrolled prospectively in a multicenter international registry from December 1995 through March 1996. Nine-, 16- and 32-mm long NIR stents were manually crimped onto coronary balloons and deployed in native coronary (94%) and saphenous vein graft (6%) lesions. Seventy-four percent of patients underwent elective stenting for primary or restenotic lesions, 21% for a suboptimal angioplasty result and 5% for threatened or abrupt vessel closure. Fifty-two percent of patients presented with unstable angina, 48% had a previous myocardial infarction, and 45% had multivessel disease. Coronary lesions were frequently complex, occurring in relatively small arteries (mean [±SD] reference diameter 2.8 ± 0.6 mm). Patients were followed up for 6 months for the occurrence of major adverse cardiovascular events. Results. Stent deployment was accomplished in 98% of lesions. Mean minimal lumen diameter increased by 1.51 ± 0.51 mm (from 1.09 ± 0.43 mm before to 2.60 ± 0.50 mm after the procedure). Mean percent diameter stenosis decreased from 61 ± 13% before to 17 ± 7% after intervention. A successful interventional procedure with <50% diameter stenosis of all treatment site lesions and no major adverse cardiac events within 30 days occurred in 95% of patients. Event-free survival at 6 months was 82%. Ninety-four percent of surviving patients were either asymptomatic or had mild stable angina at 6 month follow-up. Conclusions. Despite unfavorable clinical and angiographic characteristics of the majority of patients enrolled, the acute angiographic results and early clinical outcome after NIR stent deployment were very promising. A prospective, randomized trial comparing the NIR stent with other currently available stents appears warranted

    Magnetically navigated percutaneous coronary intervention in distal and/or complex lesions may improve procedural outcome and material consumption

    No full text
    Aims: Comparison of magnetic guidewire navigation in percutaneous coronary intervention (magnetic PCI) across distal and /or complex lesions versus conventional navigation (conventional PCI). Methods and results: Forty-seven consecutive patients (age 61±10yr) undergoing elective single vessel magnetic PCI for distal and/or complex lesions were matched by age and lesion location with 45 patients undergoing conventional PCI (age 63±10yr). Technical success rate was defined

    Endothelial dysfunction and the occurrence of radial artery spasm during transradial coronary procedures: The ACRA-Spasm study

    No full text
    Aims: The aim of this study was to analyse the relation between endothelial dysfunction (ED) and the occurrence of radial artery spasm (RAS) during transradial coronary procedures. Methods and results: From May 2014 to June 2015, endothelial function was assessed by EndoPAT and FMD before the procedure in 165 patients referred for coronary angiography or intervention. The primary endpoint was RAS, defined by patient's symptoms and procedural characteristics. The mean age of the study population was 63 years and 71% were male. In total 16% of the patients experienced RAS. The incidence of RAS did not differ between patients with and without ED (13.8% vs. 20.2%, OR 0.63, 95% CI: 0.25-1.58, p=0.32). The strongest predictors of RAS were a ratio of radial artery inner diameter and sheath outer diameter smaller than 1 (OR 4.7, 95% CI: 1.35-16.5, p=0.009) and a combination of clinical characteristics presented as an RAS risk score of at least 4 (p=0.007, OR 3.7, 95% CI: 1.37-9.89). Conclusions: Endothelial dysfunction was not found to be a predictor of the occurrence of radial artery spasm in a cohort of patients undergoing elective heart catheterisation. Radial artery-sheath mismatch is the strongest pre-procedural predictor of RAS

    Impact of sheath size and hemostasis time on radial artery patency after transradial coronary angiography and intervention in Japanese and non-Japanese patients: A substudy from RAP and BEAT (Radial Artery Patency and Bleeding, Efficacy, Adverse evenT) randomized multicenter trial

    No full text
    Background: During transradial (TR) access, it remains unclear whether differences in baseline patients characteristics and hemostasis care impact the rate of radial artery occlusion (RAO). We sought to compare the rate of RAO after TR access with the 6 French(Fr) Glidesheath Slender (GSS6Fr, Terumo, Japan) or a standard 5 Fr sheath in Japanese and non-Japanese patients. Methods and Results: The Radial Artery Patency and Bleeding, Efficacy, Adverse evenT (RAP and BEAT) trial randomized 1,836 patients undergoing TR coronary angiography and/or interventions to receive the GSS6Fr or the standard 5 Fr Glidesheath (GS5Fr, Terumo, Japan). Out of this study population, 1,087 were Japanese patients and 751 non-Japanese patients. The overall incidence of RAO was significantly higher in Japanese patients (3.6% vs. 1.2%, P = 0.002). Use of GSS6Fr was associated with higher rates of RAO than GS5Fr in Japanese patients (5% vs. 2.2%, P = 0.02) and with similar RAO rates in non-Japanese patients (1.3 vs. 1.1%, P = 1). The mean hemostasis time was significantly longer in Japanese patients (378 ± 253 vs. 159 ± 136 min, P < 0.001) and more Japanese patients had a hemostasis time of more than 6 hr (16.2% vs. 4.9%, P < 0.0001). Longer hemostasis time was an independent predictor of RAO (OR per additional hour 1.070, 95% CI 1.008–1.136, P = 0.03). Conclusions: Use of GSS6Fr was associated with a higher rate of RAO than a standard 5 Fr sheath in Japanese patients but not in non-Japanese patients. Whether improvement in post-procedural care and reduced hemostasis time could impact the incidence of RAO in Japanese patients should be further assessed

    ACRA perfusion study the impact of transradial intervention on digital hand perfusion

    No full text
    BACKGROUND: Transradial intervention (TRI) may impair digital perfusion with hand dysfunction as a result. However, the effect of TRI on digital perfusion has never been investigated, including the influence of variations of the collateral arterial network and the effect on hand dysfunction. METHODS AND RESULTS: We investigated the effect of TRI on digital perfusion by laser Doppler perfusion imaging. Laser Doppler perfusion imaging was performed at baseline, during radial access, TR band application, and at discharge. We compared tissue perfusion of the homolateral thumb (access site) with the contralateral thumb (comparator) during radial access as primary outcome. The hand circulation was assessed with angiography. Upper extremity function was evaluated with the validated QuickDASH questionnaire at baseline and follow-up. A significant reduction of tissue perfusion was observed during radial access and TR band application in the homolateral thumb (-32%, -32%, respectively) and contralateral thumb (-34%, -21%, respectively). We detected no perfusion difference between the homolateral and contralateral thumb during radial access (217; interquartile range, 112-364 versus 209; interquartile range, 99-369 arbitrary flux units; P=0.59). Reduced perfusion of the thumb during radial access was not associated with incompleteness of the superficial palmar arch ( P=0.13). Digital perfusion improved at discharge, though it remained below baseline levels (homolateral -11% and contralateral -14%). Hand dysfunction at 18 months was not associated with TRI-induced perfusion reduction ( P=0.54). CONCLUSIONS: TRI is safe. Digital perfusion is reduced in both hands during radial access and TR band application but is not associated with future loss of hand function and variations of the arterial hand supply

    A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease

    No full text
    Balloon-expandable coronary-artery stents were developed to prevent coronary restenosis after coronary angioplasty. These devices hold coronary vessels open at sites that have been dilated. However, it is unknown whether stenting improves long-term angiographic and clinical outcomes as compared with standard balloon angioplasty