8 research outputs found
Integrating water quality index, GIS and multivariate statistical techniques towards a better understanding of drinking water quality
Groundwater is considered as an imperative component of the accessible water assets across the world. Due to urbanization,
industrialization and intensive farming practices, the groundwater resources have been exposed to large-scale depletion
and quality degradation. The prime objective of this study was to evaluate the groundwater quality for drinking purposes
in Mewat district of Haryana, India. For this purpose, twenty-five groundwater samples were collected from hand pumps
and tube wells spread over the entire district. Samples were analyzed for pH, electrical conductivity (EC), total dissolved
solids (TDS), total hardness (TH), turbidity, total alkalinity (TA), cations and anions in the laboratory using the standard
methods. Two different water quality indices (weighted arithmetic water quality index and entropy weighted water quality
index) were computed to characterize the groundwater quality of the study area. Ordinary Kriging technique was applied to
generate spatial distribution map of the WQIs. Four semivariogram models, i.e. circular, spherical, exponential and Gaussian
were used and found to be the best fit for analyzing the spatial variability in terms of weighted arithmetic index (GWQI) and
entropy weighted water quality index (EWQI). Hierarchical cluster analysis (HCA), principal component analysis (PCA)
and discriminant analysis (DA) were applied to provide additional scientific insights into the information content of the
groundwater quality data available for this study. The interpretation of WQI analysis based on GWQI and EWQI reveals
that 64% of the samples belong to the “poor” to “very poor” bracket. The result for the semivariogram modeling also shows
that Gaussian model obtains the best fit for both EWQI and GWQI dataset. HCA classified 25 sampling locations into three
main clusters of similar groundwater characteristics. DA validated these clusters and identified a total of three significant
variables (pH, EC and Cl) by adopting stepwise method. The application of PCA resulted in three factors explaining 69.81%
of the total variance. These factors reveal how processes like rock water interaction, urban waste discharge and mineral dissolution
affect the groundwater quality
Minimizing Errors in RT-PCR Detection and Quantification of SARS-CoV-2 RNA for Wastewater Surveillance
Wastewater surveillance for pathogens using the reverse transcription-polymerase chain reaction (RT-PCR) is an effective, resource-efficient tool for gathering additional community-level public health information, including the incidence and/or prevalence and trends of coronavirus disease-19 (COVID-19). Surveillance of SARS-CoV-2 in wastewater may provide an early-warning signal of COVID-19 infections in a community. The capacity of the world’s environmental microbiology and virology laboratories for SARS-CoV-2 RNA characterization in wastewater is rapidly increasing. However, there are no standardized protocols nor harmonized quality assurance and quality control (QA/QC) procedures for SARS-CoV-2 wastewater surveillance. This paper is a technical review of factors that can lead to false-positive and -negative errors in the surveillance of SARS-CoV-2, culminating in recommendations and strategies that can be implemented to identify and mitigate these errors. Recommendations include, stringent QA/QC measures, representative sampling approaches, effective virus concentration and efficient RNA extraction, amplification inhibition assessment, inclusion of sample processing controls, and considerations for RT-PCR assay selection and data interpretation. Clear data interpretation guidelines (e.g., determination of positive and negative samples) are critical, particularly during a low incidence of SARS-CoV-2 in wastewater. Corrective and confirmatory actions must be in place for inconclusive and/or potentially significant results (e.g., initial onset or reemergence of COVID-19 in a community). It will also be prudent to perform inter-laboratory comparisons to ensure results are reliable and interpretable for ongoing and retrospective analyses. The strategies that are recommended in this review aim to improve SARS-CoV-2 characterization for wastewater surveillance applications. A silver lining of the COVID-19 pandemic is that the efficacy of wastewater surveillance was demonstrated during this global crisis. In the future, wastewater will play an important role in the surveillance of a range of other communicable diseases.Highlights: Harmonized QA/QC procedures for SARS-CoV-2 wastewater surveillance are lacking; Wastewater analysis protocols are not optimized for trace analysis of viruses; False-positive and -negative errors have consequences for public health responses; Inter-laboratory studies utilizing standardized reference materials and protocols are needed.info:eu-repo/semantics/publishedVersio
A global review of the microbiological quality and potential health risks associated with roof-harvested rainwater tanks
Abstract A broad body of literature has been published regarding roof-harvested rainwater quality around the world. In particular, the presence of fecal indicator bacteria and pathogenic microorganisms has raised concerns regarding the acceptability of rainwater for potable and non-potable uses. As the use of molecular assays has improved understanding of the diverse microbial communities present in rainwater tanks and their role in providing benefits or harm to human health, a comprehensive review is needed to summarize the state of the science in this area. To provide a summary of microbial contaminants in rainwater tanks and contextual factors, a comprehensive review was conducted here to elucidate the uses of rainwater, factors affecting water quality, concentrations of fecal indicators and pathogens, the attribution of pathogens to host sources using microbial source tracking, microbial ecology, human health risks determined using epidemiological approaches and quantitative microbial risk assessment, and treatment approaches for mitigating risks. Research gaps were identified for pathogen concentration data, microbial source tracking approaches for identifying the sources of microbial contamination, limitations to current approaches for assessing viability, treatment, and maintenance practices. Frameworks should be developed to assess and prioritize these factors in order to optimize public health promotion for roof-harvested rainwater
Minimizing errors in RT-PCR detection and quantification of SARS-CoV-2 RNA for wastewater surveillance
Wastewater surveillance for pathogens using reverse transcription-polymerase chain reaction (RT-PCR) is an effective and resource-efficient tool for gathering community-level public health information, including the incidence of coronavirus disease-19 (COVID-19). Surveillance of Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) in wastewater can potentially provide an early warning signal of COVID-19 infections in a community. The capacity of the world's environmental microbiology and virology laboratories for SARS-CoV-2 RNA characterization in wastewater is increasing rapidly. However, there are no standardized protocols or harmonized quality assurance and quality control (QA/QC) procedures for SARS-CoV-2 wastewater surveillance. This paper is a technical review of factors that can cause false-positive and false-negative errors in the surveillance of SARS-CoV-2 RNA in wastewater, culminating in recommended strategies that can be implemented to identify and mitigate some of these errors. Recommendations include stringent QA/QC measures, representative sampling approaches, effective virus concentration and efficient RNA extraction, PCR inhibition assessment, inclusion of sample processing controls, and considerations for RT-PCR assay selection and data interpretation. Clear data interpretation guidelines (e.g., determination of positive and negative samples) are critical, particularly when the incidence of SARS-CoV-2 in wastewater is low. Corrective and confirmatory actions must be in place for inconclusive results or results diverging from current trends (e.g., initial onset or reemergence of COVID-19 in a community). It is also prudent to perform interlaboratory comparisons to ensure results' reliability and interpretability for prospective and retrospective analyses. The strategies that are recommended in this review aim to improve SARS-CoV-2 characterization and detection for wastewater surveillance applications. A silver lining of the COVID-19 pandemic is that the efficacy of wastewater surveillance continues to be demonstrated during this global crisis. In the future, wastewater should also play an important role in the surveillance of a range of other communicable diseases. Crown Copyright (C) 2021 Published by Elsevier B.V.Peer reviewe
Minimizing errors in RT-PCR detection and quantification of SARS-CoV-2 RNA for wastewater surveillance
Wastewater surveillance for pathogens using reverse transcription-polymerase chain reaction (RT-PCR) is an effective and resource-efficient tool for gathering community-level public health information, including the incidence of coronavirus disease-19 (COVID-19). Surveillance of Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) inwastewater can potentially provide an earlywarning signal of COVID-19 infections in a community. The capacity of the world's environmental microbiology and virology laboratories for SARS-CoV-2 RNA characterization in wastewater is increasing rapidly. However, there are no standardized protocols or harmonized quality assurance and quality control (QA/QC) procedures for SARS-CoV-2 wastewater surveillance. This paper is a technical review of factors that can cause false-positive and false-negative errors in the surveillance of SARS-CoV-2 RNA inwastewater, culminating in recommended strategies that can be implemented to identify and mitigate some of these errors. Recommendations include stringent QA/QC measures, representative sampling approaches, effective virus concentration and efficient RNA extraction, PCR inhibition assessment, inclusion of sample processing controls, and considerations for RT-PCR assay selection and data interpretation. Clear data interpretation guidelines (e.g., determination of positive and negative samples) are critical, particularlywhen the incidence of SARS-CoV-2 inwastewater is low. Corrective and confirmatory actionsmust be in place for inconclusive results or results diverging fromcurrent trends (e.g., initial onset or reemergence of COVID-19 in a community). It is also prudent to perform interlaboratory comparisons to ensure results' reliability and interpretability for prospective and retrospective analyses. The strategies that are recommended in this review aim to improve SARS-CoV-2 characterization and detection for wastewater surveillance applications. A silver lining of the COVID-19 pandemic is that the efficacy of wastewater surveillance continues to be demonstrated during this global crisis. In the future, wastewater should also play an important role in the surveillance of a range of other communicable diseases