77 research outputs found

    Sensor Calibration System for Enhancement of Quality of Information

    Get PDF
    Calibration of different types of industrial instruments is the prerequisite of any of the industrial installations before coming under operation. Modern calibration can be categorized based on the physical quantities they are designed to measure. The categorization may internationally vary but the basic notion of calibration is clear and straight forward whereas the associated standards of calibration vary from parameter to parameter under different physical environment. Here a data acquisition system has been developed using Arduino Uno R3 and infrared emitter- detector pair. An experimental set up has been build which can collect data from the sensor under calibration, namely ultrasonic sensor HC-SR04. The data acquisition system includes the set up called, the ground truth apparatus which specifically has been designed to carry out repeated experiments to collect data. The process of collection of data involves the infrared based obstacle detection technique. A number of errors compensation technique are being applied. These methods of error compensation technique involves feed-forward neural network with backpropagation, conjugate gradient and regularization training algorithm. Finally a parameter based analysis of performance for different error compensation techniques is done. Based on the performance analysis some novel approaches for calibrating the information generated by the sensor has been prescribed. A clear distinction in approach between data calibration and instrument calibration is established

    Seasonal Abundance and Host-Feeding Patterns of Anopheline Vectors in Malaria Endemic Area of Iran

    Get PDF
    Seasonal abundance and tendency to feed on humans are important parameters to measure for effective control of malaria vectors. The objective of this study was to describe relation between feeding pattern, abundance, and resting behavior of four malaria vectors in southern Iran. This study was conducted in ten indicator villages (based on malaria incidence and entomological indices) in mountainous/hilly and plain regions situated south and southeastern Iran. Mosquito vectors were collected from indoor as well as outdoor shelters and the blood meals were examined by ELISA test. Over all 7654 female Anopheles spp. were captured, the most common species were Anopheles stephensi, An. culicifacies, An. fluviatilis, and An. d'thali. The overall human blood index was 37.50%, 19.83%, 16.4%, and 30.1% for An. fluviatilis, An. stephensi, An. culicifacies, and An. d'thali, respectively. In addition, An. fluviatilis fed on human blood during the entire year but the feeding behavior of An. stephensi and An. culicifacies varied according to seasons. Overall, the abundance of the female mosquito positive to human blood was 4.25% per human shelter versus 17.5% per animal shelter. This result indicates that the vectors had tendency to rest in animal shelters after feeding on human. Therefore, vector control measure should be planned based on such as feeding pattern, abundance, and resting behavior of these vectors in the area

    The biomechanical effects of allograft wedges used for large corrections during medial opening wedge high tibial osteotomy

    Get PDF
    The inclusion of an allograft wedge during medial opening wedge high tibial osteotomy has been shown to lead to satisfactory time-to-union in larger corrections (>10°). Such large corrections are associated with greater incidences of intraoperative hinge fracture and reduced construct stability. The purpose of this study was to investigate the biomechanical stability that an allograft wedge brings to an osteotomy. Ten medium-size fourth generation artificial sawbone tibiae underwent 12 mm biplanar medial opening wedge high tibial osteotomy with a standard Tomofix plate. Five tibiae had an allograft wedge inserted into the osteotomy gap prior to plate fixation (allograft group). The gap in the remaining tibiae was left unfilled (control group). Each group underwent static compression testing and cyclical fatigue testing until failure of the osteotomy. Peak force, valgus malrotation, number of cycles, displacement and stiffness around the tibial head were analysed. Intraoperative hinge fractures occurred in all specimens. Under static compression, the allograft group withstood higher peak forces (6.01 kN) compared with the control group (5.12 kN). Valgus malrotation was lower, and stiffness was higher, in the allograft group. During cyclical fatigue testing, results within the allograft group were more consistent than within the control group. This may indicate more predictable results in large osteotomies with an allograft. Tibial osteotomies with allograft wedges appear beneficial for larger corrections, and in cases of intraoperative hinge fracture, due to the added construct stability they provide, and the consistency of results compared with tibial osteotomies without a graft

    Poor follow-up rates at a self-pay northern Indian tertiary AIDS clinic

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In many developing countries, out-of-pocket payment remains a primary mechanism by which patients infected with HIV access treatment. In India, this has been changing as the National AIDS Control Organization (NACO) has been rolling out free antiretroviral therapy throughout the country since 2004. The vast majority of patients, however, remain without access to free medicines.</p> <p>Methods</p> <p>A retrospective chart review was performed on data obtained from a registry of ninety-three (93) patients attending a self-pay clinic at the All India Institute of Medical Sciences in Delhi, India. Multivariable Cox proportional hazard and logistic regression models were explored to assess the relationship between lost-to-follow-up status and the predictor variables: age, sex, household income, baseline CD4 count, and distance from clinic.</p> <p>Results</p> <p>Lost-to-follow-up rates were very high; 68% (63/93) were lost-to-follow-up till the time of chart review, including 59% (55/93) who were lost within one year. In both regression models, younger age, low baseline CD4 counts, and low income level were significantly associated with increased risk of lost-to-follow-up. Additionally, there was a significant interaction between income and CD4 counts. The patients with both low CD4 counts and low income level were more likely to be lost-to-follow-up than would be predicted by each covariable alone.</p> <p>Conclusion</p> <p>In this small cohort of AIDS patients attending a self-pay antiretroviral clinic at a large tertiary care center in Delhi, India, follow-up rates were quite poor. Poorer patients tended to present to clinic with more depressed CD4 counts and were less likely to be retained in care. These findings indicate that greater strides must be taken to improve the recruitment and retention of poor patients. The expansion of free antiretrovirals is one step among many necessary to achieve this objective.</p

    Combating HIV stigma in health care settings: what works?

    Get PDF
    The purpose of this review paper is to provide information and guidance to those in the health care setting about why it is important to combat HIV-related stigma and how to successfully address its causes and consequences within health facilities. Research shows that stigma and discrimination in the health care setting and elsewhere contributes to keeping people, including health workers, from accessing HIV prevention, care and treatment services and adopting key preventive behaviours

    Persistence of G10P[11] neonatal rotavirus infections in southern India

    Get PDF
    BACKGROUND: Neonatal rotavirus infections are predominantly caused by distinct genotypes restricted to this age-group and are mostly asymptomatic. METHOD: Stool samples from neonates admitted for >48 h in neonatal intensive care units (NICUs) in Vellore (2014–2015) and Chennai (2015–2016) in southern India, and from neonates born at hospitals in Vellore but not admitted to NICUs (2015–2016) were tested for rotavirus by ELISA and genotyped by hemi-nested RT-PCR. RESULTS: Of 791 neonates, 150 and 336 were recruited from Vellore and Chennai NICUs, and 305 were born in five hospitals in Vellore. Positivity rates in the three settings were 49.3% (74/150), 29.5% (99/336) and 54% (164/305), respectively. G10P[11] was the commonly identified genotype in 87.8% (65/74), 94.9% (94/99) and 98.2% (161/164) of the neonates in Vellore and Chennai NICUs, and those born at Vellore hospitals, respectively. Neonates delivered by lower segment cesarian section (LSCS) at Vellore hospitals, not admitted to NICUs, had a significantly higher odds of acquiring rotavirus infection compared to those delivered vaginally [p = 0.002, OR = 2.4 (1.4–4.3)]. CONCLUSIONS: This report demonstrates the persistence of G10P[11] strain in Vellore and Chennai, indicating widespread neonatal G10P[11] strain in southern India and their persistence over two decades, leading to interesting questions about strain stability

    Minimally invasive total knee replacement : techniques and results

    Get PDF
    In this review, we outlined the definition of minimally invasive surgery (MIS) in total knee replacement (TKR) and described the different surgical approaches reported in the literature. Afterwards we went through the most recent studies assessing MIS TKR. Next, we searched for potential limitations of MIS knee replacement and tried to answer the following questions: Are there selective criteria and specific patient selection for MIS knee surgery? If there are, then what are they? After all, a discussion and conclusion completed this article. There is certainly room for MIS or at least less invasive surgery (LIS) for appropriate selected patients. Nonetheless, there are differences between approaches. Mini medial parapatellar is easy to master, quick to perform and potentially extendable, whereas mini subvastus and mini midvastus are trickier and require more caution related to risk of hematoma and VMO nerve damage. Current evidence on the safety and efficacy of mini-incision surgery for TKR does not appear fully adequate for the procedure to be used without special arrangements for consent and for audit or continuing research. There is an argument that a sudden jump from standard TKR to MIS TKR, especially without computer assistance such as navigation, patient specific instrumentation (PSI) or robotic, may breach a surgeon's duty of care toward patients because it exposes patients to unnecessary risks. As a final point, more evidence is required on the long-term safety and efficacy of this procedure which will give objective shed light on real benefits of MIS TKR

    Anterior Closing-Wedge High Tibial Osteotomy Using Patient-Specific Cutting Guide in Chronic Anterior Cruciate LigamenteDeficient Knees

    No full text
    An increased posterior tibial slope has been identified as an independent risk factor for anterior cruciate lig-ament (ACL) graft rupture, with a critical threshold of 12 degrees. Surgical slope correction by anterior closing wedge (ACW)-high tibial osteotomy (HTO) can reduce ACL force and anterior tibial translation with good clinical outcomes when combined with revision ACL reconstruction. Performing ACW-HTO preserving the tibial tubercule can be challenging for inexperienced surgeons. Patient-specific cutting guides have been shown to be effective in facilitating the surgeon's learning curve in medial opening wedge-HTO by reducing operative time and the use of fluoroscopy as well as decreasing anxiety. The present technique describes a retro-tibial tubercule ACW-HTO using a patient-specific cutting guide
    corecore