Validation of four automatic devices for self-measurement of blood pressure according to the international protocol of the European Society of Hypertension
Jirar Topouchian1, Davide Agnoletti1, Jacques Blacher1, Ahmed Youssef1, Isabel Ibanez2,3, Jose Khabouth2, Salwa Khawaja2, Layale Beaino2, Roland Asmar1–31Centre de Diagnostic, Hôpital Hôtel-Dieu, Paris, France; 2Hôpital Libanais and Faculté Libanaise de Médecine, Beirut, Lebanon; 3Foundation-Medical Research Institutes, Geneva, SwitzerlandBackground: Four oscillometric devices for self-measurement of blood pressure (SBPM) were evaluated according to the European Society of Hypertension (ESH) international protocol and its 2010 revision in four separate studies. The Omron® M2, Omron M3, and Omron M6 measure blood pressure (BP) at the brachial level, while the Omron R2 measures BP at the wrist level.Methods: The international protocol requires a total number of 33 subjects in which the validation is performed. The Omron M2 and Omron R2 were validated in 2009 according to the ESH international protocol, while the Omron M3 and Omron M6 were validated in 2010–2011 according to the 2010 ESH international protocol revision. The protocol procedures were followed precisely.Results: All four tested devices passed the validation process. The mean differences between the device and mercury readings were 2.7 ± 5.0 and –1.4 ± 3.2 mmHg for systolic and diastolic BP, respectively, using the Omron M2 device, and 1.7 ± 3.2 and –0.9 ± 2.6 mmHg using the Omron M3, 1.6 ± 2.9 and -0.9 ± 2.5 mmHg using the Omron M6, and –1.1 ± 4.8 and –0.9 ± 4.3 mmHg using the Omron R2.Conclusion: Readings from the Omron M2, Omron M3, Omron M6, and Omron R2, differing by less than 5, 10, and 15 mmHg, fulfill the ESH international protocol and its 2010 revision requirements. Therefore, each of these four devices can be used by patients for SBPM.Keywords: Omron R2, M2, M3, M6, blood pressure measurement, validation, international protocol, European Society of Hypertensio
Adaptation and Implementation of the "Kidney Disease: Improving Global Outcomes (KDIGO)" Guidelines for Evaluation and Management of Mineral and Bone Disorders in Chronic Kidney Disease for Practice in the Middle East Countries
This review presents the views of an expert group of nephrologists from the Middle East along with an international expert on adaptation and implementation of the 2009 Kidney Disease: Improving Global Outcomes (KDIGO) guidelines for evaluation and manage-ment of mineral and bone disorders in chronic kidney disease (CKD-MBD) for practice in the Middle East countries. The members of the panel examined the KDIGO guidelines and formulated recommendations that can be implemented practically for the management of CKD-MBD in the Middle East. There was a broad agreement on most of the recommendations made by the KDIGO work-group. However, the panelists commented on specific areas and amplified certain concepts that might help the nephrologists in the Middle East. The final document was reviewed by all participants as well as by members of the Middle East task force implementation group for KDIGO guidelines. Their comments were incorporated. The guideline statements are presented along with detailed rationale and relevant discussion as well as limitations of the evidence. The panel recognized the need to upgrade the suggestion of KDIGO related to lateral abdominal radiograph and echocardiogram in patients with CKD stages 3-5D into a stronger recommendation. The panel underlined the risk of hyper-phosphatemia to CKD-MBD and the importance of prompt initiation or modification of therapy according to rising trends in para-thyroid hormone level. They recommended the use of non-calcium-based phosphate binders as the first-line therapy in CKD patients with signs of vascular calcification. The panel agreed that all aspects of the KDIGO recommendations concerning bone biopsy, evaluation and treatment of bone disease after kidney trans-plantation should be implemented as such