2 research outputs found

    Automation of intracoronary continuous thermodilution for absolute coronary flow and microvascular resistance measurements

    Full text link
    Aim: Microvascular resistance reserve (MRR) as derived from continuous intracoronary thermodilution specifically quantifies microvasculature function. As originally described, the technique necessitates reinstrumentation of the artery and manual reprogramming of the infusion pump when performing resting and hyperemic measurements. To simplify and to render this procedure operator-independent, we developed a fully automated method. The aim of the present study is to validate the automated procedure against the originally described one. Methods and results: For the automated procedure, an infusion pump was preprogrammed to allow paired resting-hyperemic thermodilution assessment without interruption. To validate the accuracy of this new approach, 20 automated measurements were compared to those obtained in the same vessels with conventional paired resting-hyperemic thermodilution measurements (i.e., with a sensor pullback at each infusion rate and manual reprogramming of the infusion pump). A close correlation between the conventional and the automated measuring technique was found for resting flow (Qrest : r = 0.89, mean bias = 2.52; SD = 15.47), hyperemic flow (Qhyper : r = 0.88, mean bias = -2.65; SD = 27.96), resting microvascular resistance (Rμ-rest : r = 0.90, mean bias = 52.14; SD = 228.29), hyperemic microvascular resistance Rμ-hyper : r = 0.92, mean bias = 12.95; SD = 57.80), and MRR (MRR: r = 0.89, mean bias = 0.04, SD = 0.59). Procedural time was significantly shorter with the automated method (5'25″ ± 1'23″ vs. 4'36″ ± 0'33″, p = 0.013). Conclusion: Continuous intracoronary thermodilution-derived measurements of absolute flow, absolute resistance, and MRR can be fully automated. This further shortens and simplifies the procedure when performing paired resting-hyperemic measurements. Keywords: continuous intracoronary thermodilution; coronary flow reserve; coronary physiology; microvascular function; microvascular resistance reserv

    Hypothermia for Cardioprotection in Patients with St-Elevation Myocardial Infarction: Do Not Give It the Cold Shoulder Yet!

    Get PDF
    The timely revascularization of an occluded coronary artery is the cornerstone of treatment in patients with ST-elevation myocardial infarction (STEMI). As essential as this treatment is, it can also cause additional damage to cardiomyocytes that were still viable before reperfusion, increasing infarct size. This has been termed “myocardial reperfusion injury”. To date, there is still no effective treatment for myocardial reperfusion injury in patients with STEMI. While numerous attempts have been made to overcome this hurdle with various experimental therapies, the common denominator of these therapies is that, although they often work in the preclinical setting, they fail to demonstrate the same results in human trials. Hypothermia is an example of such a therapy. Although promising results were derived from experimental studies, multiple randomized controlled trials failed to do the same. This review includes a discussion of hypothermia as a potential treatment for myocardial reperfusion injury, including lessons learned from previous (negative) trials, advanced techniques and materials in current hypothermic treatment, and the possible future of hypothermia for cardioprotection in patients with STEMI
    corecore