3 research outputs found
3D-printed saw guides for lower arm osteotomy, a comparison between a synthetic CT and CT-based workflow
BACKGROUND: Three-dimensional (3D)-printed saw guides are frequently used to optimize osteotomy results and are usually designed based on computed tomography (CT), despite the radiation burden, as radiation-less alternatives like magnetic resonance imaging (MRI) have inferior bone visualization capabilities. This study investigated the usability of MR-based synthetic-CT (sCT), a novel radiation-less bone visualization technique for 3D planning and design of patient-specific saw guides. METHODS: Eight human cadaveric lower arms (mean age: 78y) received MRI and CT scans as well as high-resolution micro-CT. From the MRI scans, sCT were generated using a conditional generative adversarial network. Digital 3D bone surface models based on the sCT and general CT were compared to the surface model from the micro-CT that was used as ground truth for image resolution. From both the sCT and CT digital bone models saw guides were designed and 3D-printed in nylon for one proximal and one distal bone position for each radius and ulna. Six blinded observers placed these saw guides as accurately as possible on dissected bones. The position of each guide was assessed by optical 3D-scanning of each bone with positioned saw guide and compared to the preplanning. Eight placement errors were evaluated: three translational errors (along each axis), three rotational errors (around each axis), a total translation (∆T) and a total rotation error (∆R). RESULTS: Surface models derived from micro-CT were on average smaller than sCT and CT-based models with average differences of 0.27 ± 0.30 mm for sCT and 0.24 ± 0.12 mm for CT. No statistically significant positioning differences on the bones were found between sCT- and CT-based saw guides for any axis specific translational or rotational errors nor between the ∆T (p = .284) and ∆R (p = .216). On Bland-Altman plots, the ∆T and ∆R limits of agreement (LoA) were within the inter-observer variability LoA. CONCLUSIONS: This research showed a similar error for sCT and CT digital surface models when comparing to ground truth micro-CT models. Additionally, the saw guide study showed equivalent CT- and sCT-based saw guide placement errors. Therefore, MRI-based synthetic CT is a promising radiation-less alternative to CT for the creation of patient-specific osteotomy surgical saw guides
Nationwide Association of Surgical Performance of Minimally Invasive Esophagectomy With Patient Outcomes
IMPORTANCE: Suboptimal surgical performance is hypothesized to be associated with less favorable patient outcomes in minimally invasive esophagectomy (MIE). Establishing this association may lead to programs that promote better surgical performance of MIE and improve patient outcomes.OBJECTIVE: To investigate associations between surgical performance and postoperative outcomes after MIE.DESIGN, SETTING, AND PARTICIPANTS: In this nationwide cohort study of 15 Dutch hospitals that perform more than 20 MIEs per year, 7 masked expert MIE surgeons assessed surgical performance using videos and a previously developed and validated competency assessment tool (CAT). Each hospital submitted 2 representative videos of MIEs performed between November 4, 2021, and September 13, 2022. Patients registered in the Dutch Upper Gastrointestinal Cancer Audit between January 1, 2020, and December 31, 2021, were included to examine patient outcomes.EXPOSURE: Hospitals were divided into quartiles based on their MIE-CAT performance score. Outcomes were compared between highest (top 25%) and lowest (bottom 25%) performing quartiles. Transthoracic MIE with gastric tube reconstruction.MAIN OUTCOME AND MEASURE: The primary outcome was severe postoperative complications (Clavien-Dindo ≥3) within 30 days after surgery. Multilevel logistic regression, with clustering of patients within hospitals, was used to analyze associations between performance and outcomes.RESULTS:In total, 30 videos and 970 patients (mean [SD] age, 66.6 [9.1] years; 719 men [74.1%]) were included. The mean (SD) MIE-CAT score was 113.6 (5.5) in the highest performance quartile vs 94.1 (5.9) in the lowest. Severe postoperative complications occurred in 18.7% (41 of 219) of patients in the highest performance quartile vs 39.2% (40 of 102) in the lowest (risk ratio [RR], 0.50; 95% CI, 0.24-0.99). The highest vs the lowest performance quartile showed lower rates of conversions (1.8% vs 8.9%; RR, 0.21; 95% CI, 0.21-0.21), intraoperative complications (2.7% vs 7.8%; RR, 0.21; 95% CI, 0.04-0.94), and overall postoperative complications (46.1% vs 65.7%; RR, 0.54; 95% CI, 0.24-0.96). The R0 resection rate (96.8% vs 94.2%; RR, 1.03; 95% CI, 0.97-1.05) and lymph node yield (mean [SD], 38.9 [14.7] vs 26.2 [9.0]; RR, 3.20; 95% CI, 0.27-3.21) increased with oncologic-specific performance (eg, hiatus dissection, lymph node dissection). In addition, a high anastomotic phase score was associated with a lower anastomotic leakage rate (4.6% vs 17.7%; RR, 0.14; 95% CI, 0.06-0.31).CONCLUSIONS AND RELEVANCE: These findings suggest that better surgical performance is associated with fewer perioperative complications for patients with esophageal cancer on a national level. If surgical performance of MIE can be improved with MIE-CAT implementation, substantially better patient outcomes may be achievable.</p
Nationwide Association of Surgical Performance of Minimally Invasive Esophagectomy With Patient Outcomes
IMPORTANCE: Suboptimal surgical performance is hypothesized to be associated with less favorable patient outcomes in minimally invasive esophagectomy (MIE). Establishing this association may lead to programs that promote better surgical performance of MIE and improve patient outcomes.OBJECTIVE: To investigate associations between surgical performance and postoperative outcomes after MIE.DESIGN, SETTING, AND PARTICIPANTS: In this nationwide cohort study of 15 Dutch hospitals that perform more than 20 MIEs per year, 7 masked expert MIE surgeons assessed surgical performance using videos and a previously developed and validated competency assessment tool (CAT). Each hospital submitted 2 representative videos of MIEs performed between November 4, 2021, and September 13, 2022. Patients registered in the Dutch Upper Gastrointestinal Cancer Audit between January 1, 2020, and December 31, 2021, were included to examine patient outcomes.EXPOSURE: Hospitals were divided into quartiles based on their MIE-CAT performance score. Outcomes were compared between highest (top 25%) and lowest (bottom 25%) performing quartiles. Transthoracic MIE with gastric tube reconstruction.MAIN OUTCOME AND MEASURE: The primary outcome was severe postoperative complications (Clavien-Dindo ≥3) within 30 days after surgery. Multilevel logistic regression, with clustering of patients within hospitals, was used to analyze associations between performance and outcomes.RESULTS:In total, 30 videos and 970 patients (mean [SD] age, 66.6 [9.1] years; 719 men [74.1%]) were included. The mean (SD) MIE-CAT score was 113.6 (5.5) in the highest performance quartile vs 94.1 (5.9) in the lowest. Severe postoperative complications occurred in 18.7% (41 of 219) of patients in the highest performance quartile vs 39.2% (40 of 102) in the lowest (risk ratio [RR], 0.50; 95% CI, 0.24-0.99). The highest vs the lowest performance quartile showed lower rates of conversions (1.8% vs 8.9%; RR, 0.21; 95% CI, 0.21-0.21), intraoperative complications (2.7% vs 7.8%; RR, 0.21; 95% CI, 0.04-0.94), and overall postoperative complications (46.1% vs 65.7%; RR, 0.54; 95% CI, 0.24-0.96). The R0 resection rate (96.8% vs 94.2%; RR, 1.03; 95% CI, 0.97-1.05) and lymph node yield (mean [SD], 38.9 [14.7] vs 26.2 [9.0]; RR, 3.20; 95% CI, 0.27-3.21) increased with oncologic-specific performance (eg, hiatus dissection, lymph node dissection). In addition, a high anastomotic phase score was associated with a lower anastomotic leakage rate (4.6% vs 17.7%; RR, 0.14; 95% CI, 0.06-0.31).CONCLUSIONS AND RELEVANCE: These findings suggest that better surgical performance is associated with fewer perioperative complications for patients with esophageal cancer on a national level. If surgical performance of MIE can be improved with MIE-CAT implementation, substantially better patient outcomes may be achievable.</p