    Local treatment of cancellous bone grafts with BMP-7 and zoledronate increases both the bone formation rate and bone density: A bone chamber study in rats

    Get PDF
    Background and purpose The remodeling of morselized bone grafts in revision surgery can be enhanced by an anabolic substance such as a bone morphogenetic protein (BMP). On the other hand, BMPs boost catabolism and might cause a premature resorption, both of the graft and of the new-formed bone. Bisphosphonates inactivate osteoclasts and can be used to control the resorption. We studied a combination of both drugs as a local admix to a cancellous allograft. Methods Cancellous bone allografts were harvested and freeze-dried. Either saline, BMP-7, the bisphosphonate zoledronate, or a combination of BMP-7 and zoledronate were added in solution. The grafts were placed in bone conduction chambers and implanted in the proximal tibia of 34 rats. The grafts were harvested after 6 weeks and evaluated by histomorphometry. Results Bone volume/total volume (BV/TV) was 50% in the grafts treated with the combination of BMP-7 and zoledronate and 16% in the saline controls (p < 0.001). In the zoledronate group BV/TV was 56%, and in the BMP group it was 14%. The ingrowth distance of new bone into the graft was 3.5 mm for the combination of BMP-7 and zoledronate and 2.6 mm in the saline control (p = 0.002). The net amount of retained remodeled bone was more than 4 times higher when BMP-7 and zoledronate were combined than in the controls. Interpretation An anabolic drug like BMP-7 can be combined with an anti-catabolic bisphosphonate as local bone graft adjunct, and the combination increases the amount of remaining bone after remodeling is complete

    Wear and Loosening in Cemented Hip Arthroplasty

    No full text
    The mechanisms of loosening in total hip arthroplasty (THA) and the role of polyethylene (PE) wear debris in this process is unclear. Radiographic measurements showed that THA with 32 mm heads have about 3 times greater volumetric wear than those with 22 mm heads. If PE debris were the main cause of loosening, then there should be an obvious difference in revision rates between the prostheses with these two head sizes. However, the analysis of revision rates, due to aseptic loosening, showed no significant difference. These findings do not support the hypothesis that wear debris is the main cause of loosening. The intracapsular pressure and ultrasonographic synovitis in THA with loose components was studied. The pressure was high and with cyclic alterations dependent on hip joint movements. The synovitis in loose THA was more pronounced than in stable ones. There was a significant correlation between the intracapsular pressure with the hip in extension with inward rotation and synovitis. These results suggest that increased pressure and synovitis is important in loosening of THA. The correlation between synovitis, wear and radiographic loosening was studied. There was a significant correlation between volumetric wear and synovitis. Hips with cup loosening had significantly greater wear and synovitis than the others. In THA with loose cups the PE wear was higher than in those with loose stems. This indicates that PE debris is of certain importance in loosening of acetabular components, but of less significance in loosening of stems. The experimental study showed that bone cement, if left inside PE cups during curing, contaminates the articulating surface of the cups with cement debris. In clinical situations such contamination may predispose to increased wear

    Rinsing morcellised bone grafts with bisphosphonate solution prevents their resorption: A PROSPECTIVE RANDOMISED DOUBLE-BLINDED STUDY.

    No full text
    During revision total hip replacement using morcellised compacted bone allograft, 16 patients were randomised to receive a graft which had been rinsed in either an ibandronate solution or in saline. Patients were assessed by dual energy x-ray absorptiometry after operation and at 3, 6, 12 and 24 months. A region of interest between the tip of the femoral stem and the distal plastic plug was chosen to measure the changes in bone density over time. The study was double-blinded. In all the control patients the bone density decreased during the first three months and then remained constant at this lower level. A large proportion of the mass of the bone graft was lost. In contrast, all patients with grafts treated with bisphosphonate showed a slight increase in bone density. The difference between the groups was highly significant at all points in time. We conclude that rinsing the graft in a bisphosphonate solution prevents its resorption and may therefore reduce the risk of mechanical failure. The treatment is simple, inexpensive, and appears virtually free of risk

    No effect of femoral canal jet-lavage on the stability of cementless stems in primary hip arthroplasty : a randomised RSA study with 6 years follow-up

    No full text
    Introduction: In contrast to cemented hip prostheses, the effect of washing the bone bed with jet-lavage prior to insertion of cementless stem components in primary hip arthroplasty (THA) is unclear. Jet-lavage potentially decreases the risk of fat embolisation during rasping and stem insertion and might help in avoiding bacterial contamination. An earlier animal study has shown less debris and better-organised trabecular structure of new bone when jet-lavage was used. We hypothesised that the primary stability of cementless femoral stems implanted after jet-lavage of the femoral canal prior to stem insertion would improve with earlier stabilisation, as measured with Radiostereometry (RSA), compared with insertion without prior jet-lavage. Methods: 40 patients with primary osteoarthritis operated on with a cementless titanium grit blasted stem are included in the study. The patients were randomised to either jet-lavage or control without any lavage of the femoral canal prior to insertion of the prosthesis. The stem migration pattern was measured with RSA at 0, 3, 12, 24 and 72 months. Results: At 6 years, 19 patients remained for analysis in the jet-lavage and 18 in the control group. We found no difference in extent or pattern of migration as measured with RSA. Both groups seemed to have stabilised within 3 months after a slight subsidence and retroversion. No stem was revised or considered loose as measured with RSA. Conclusions: Washing the bone bed with jet-lavage prior to insertion of cementless stems does not affect the stability of cementless femoral components. No adverse effects were observed

    Stable migration pattern of an ultra-short anatomical uncemented hip stem : A prospective study with 2 years radiostereometric analysis follow-up

    No full text
    Introduction: Shorter, anatomically shaped and proximally loading stems have been developed to achieve better stress distribution and be more bone preserving. The purpose of this prospective study was to evaluate the migration pattern of the Proxima™ ultra-short uncemented stem using radiostereometric analysis (RSA), and to review the literature regarding the migration of short stemmed hip arthroplasty. Methods: 25 patients (28 hips) with hip osteoarthritis received a Proxima stem during total hip arthroplasty (THA). To measure stem migration, repeated RSA examinations were done during a 2 year follow up period. The patients were evaluated with the hip specific (HOOS) and the generic health (EQ5D) scores up to 1 year, and clinically for 6 years postoperatively. Results: Almost all migration occurred within the first 3 months, with mean subsidence of 0.22 mm and varus rotation of 1.04°, being the primary effect variables. After the third postoperative month and up to the 2 year RSA follow up no further significant migration occurred. The outcome scores showed substantial improvement after 1 year. No revisions were performed or indicated for any stem after a mean clinical follow up of 72.1 months. Conclusions: Like many other uncemented stems, the Proxima showed early migration up to 3 months hereafter osseointegration seems to have occurred. The achieved stability and clinical outcomes indicate favorable early results for this stem in younger patients who have good bone quality and average BMI. We found, however, the surgical technique to be slightly more demanding compared to conventional stems owing to the unique implant design that necessitates specific adjusted femoral cutting and broaching procedures

    Is removal of subchondral bone plate advantageous in cemented cup fixation? A randomized RSA study.

    No full text
    There is uncertainty regarding whether and how the subchondral bone plate should be treated during acetabular preparation for cemented cup fixation in a total hip arthroplasty. We hypothesized that removing the bone plate would improve the cement-bone interface without jeopardizing the initial cup stability, and therefore, be advantageous to long-term cup survival. We randomized 50 patients with primary osteoarthritis into two groups, one for removal and one for retention of the subchondral bone plate. The patients were evaluated during 2 years followup using repeated radiostereometric examinations, analyses of radiolucent lines, and clinical followups. Patient scoring was done using the Western Ontario and McMaster Universities Osteoarthritis Index, the Short Form-12, and the Harris hip score. Removal of the subchondral bone plate resulted in a superior cement-bone interface with less development of radiolucent lines. The radiostereometry results showed small migrations in both groups. We found no differences in cup stability between groups, although a difference was observed in rotational behavior with the removal group stabilizing in a slightly vertical position whereas the retention group showed slight but progressive rotation into a more horizontal position. No differences were found during clinical followups. Removing the subchondral bone plate, where possible, improves the cement-bone interface without jeopardizing the stability, implying better long-term cup survival. However, it is a more demanding surgical technique

    Similar migration for medial congruent and cruciate-retaining tibial components in an anatomic TKA system : a randomized controlled trial of 60 patients followed with RSA for 2 years

    No full text
    Background and purpose — There is an ongoing debate regarding the appropriate level of constraint in primary TKA. To provide increased stability and better kinematics, more resembling a natural knee, a medial congruent (MC) tibial insert has been introduced. To investigate potential impact on implant migration, we evaluated the cemented Persona TKA, randomizing between MC and cruciate-retaining (CR) tibial designs. Patients and methods — 60 patients with primary osteoarthritis were randomized to either the CR or MC tibial component. Radiostereometric analysis (RSA) examinations, evaluating translational and rotational migration as well as maximal total point motion (MTPM), were performed on the first postoperative day, at 3 months, and 1 and 2 years after surgery. Preoperative, and 1- and 2-year patient-reported outcome measures (PROMs) data (KOOS and FJS) were collected. Results — The mean tibial MTPM at 3 months were 0.48 mm (95% CI 0.37–0.58) and 0.56 mm (0.45–0.67) for the CR and MC respectively. 2 years postoperatively the respective values were 0.62 mm (0.50–0.73) and 0.73 mm (0.49–0.96). There was no statistically significant difference in migration between groups, for either the femoral or the tibial component, regarding x-, y-, and z-translations or rotations. Both CR and MC groups improved as expected in PROM scores pre- to postoperatively, but without a statistically significant difference between groups. There were no revisions or other serious adverse events related to surgery. Interpretation — The results are promising, indicating good fixation for both designs, and this is in line with other well-performing TKAs on the market. The increased medial congruity of the MC inlay does not seem to affect the migration or the PROMs up to 2 years