135 research outputs found

    Direct Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry Improves Appropriateness of Antibiotic Treatment of Bacteremia

    Get PDF
    Matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) allows the identification of microorganisms directly from positive blood culture broths. Use of the MALDI-TOF MS for rapid identification of microorganisms from blood culture broths can reduce the turnaround time to identification and may lead to earlier appropriate treatment of bacteremia. During February and April 2010, direct MALDI-TOF MS was routinely performed on all positive blood cultures. During December 2009 and March 2010 no direct MALDI-TOF MS was used. Information on antibiotic therapy was collected from the hospital and intensive care units' information systems from all positive blood cultures during the study period. In total, 253 episodes of bacteremia were included of which 89 during the intervention period and 164 during the control period. Direct performance of MALDI-TOF MS on positive blood culture broths reduced the time till species identification by 28.8-h and was associated with an 11.3% increase in the proportion of patients receiving appropriate antibiotic treatment 24 hours after blood culture positivity (64.0% in the control period versus 75.3% in the intervention period (p0.01)). Routine implementation of this technique increased the proportion of patients on adequate antimicrobial treatment within 24 hours

    Power, norms and institutional change in the European Union: the protection of the free movement of goods

    Get PDF
    How do institutions of the European Union change? Using an institutionalist approach, this article highlights the interplay between power, cognitive limits, and the normative order that underpins institutional settings and assesses their impact upon the process of institutional change. Empirical evidence from recent attempts to reinforce the protection of the free movement of goods in the EU suggests that, under conditions of uncertainty, actors with ambiguous preferences assess attempts at institutional change on the basis of the historically defined normative order which holds a given institutional structure together. Hence, path dependent and incremental change occurs even when more ambitious and functionally superior proposals are on offer

    External quality assessment of the molecular diagnostics and genotyping of meticillin-resistant Staphylococcus aureus

    Get PDF
    Two multicentre external quality assessments (EQA) for the molecular detection and genotyping of meticillin-resistant Staphylococcus aureus (MRSA) were arranged. Firstly, 11 samples containing various amounts of inactivated MRSA strains, meticillin-susceptible S. aureus (MSSA), meticillin-resistant coagulase-negative staphylococci (MRCoNS) or Escherichia coli were distributed to 82 laboratories. Samples containing 102 or 103 MRSA cells were correctly scored in only 16 and 46% of the datasets returned, respectively. Two of the used MSSA strains contained an SCCmec cassette lacking the mecA gene. There was a marked difference in the percentage of correct results for these two MSSA strains (37 and 39%) compared to the MSSA strain lacking the SCCmec cassette (88%). Secondly, a panel for MRSA genotyping, consisting of ten samples (two identical, three genetically related and five unique strains) was distributed to 19 laboratories. Seventy-three percent of the datasets recorded all samples correctly. Most pulsed-field gel electrophoresis (PFGE) protocols proved to be suboptimal, resulting in inferior resolution in the higher or lower fragment regions. The performance of molecular diagnostics for MRSA shows no significant changes since our first EQA in 2006. The first molecular typing results are encouraging. Both assessments indicate that programme expansion is required and that major performance discrepancies continue to exist

    The Development of Practice Recommendations for Drug-Disease Interactions by Literature Review and Expert Opinion

    Get PDF
    Background: Drug-disease interactions negatively affect the benefit/risk ratio of drugs for specific populations. In these conditions drugs should be avoided, adjusted, or accompanied by extra monitoring. The motivation for many drug-disease interactions in the Summary of Product Characteristics (SmPC) is sometimes insufficiently supported by (accessible) evidence. As a consequence the translation of SmPC to clinical practice may lead to non-specific recommendations. For the translation of this information to the real world, it is necessary to evaluate the available knowledge about drug-disease interactions, and to formulate specific recommendations for prescribers and pharmacists. The aim of this paper is to describe a standardized method how to develop practice recommendations for drug-disease interactions by literature review and expert opinion. Methods: The development of recommendations for drug-disease interactions will follow a six-step plan involving a multidisciplinary expert panel (1). The scope of the drug-disease interaction will be specified by defining the disease and by describing relevant effects of this drug-disease interaction. Drugs possibly involved in this drug-disease interaction are selected by checking the official product information, literature, and expert opinion (2). Evidence will be collected from the official product information, guidelines, handbooks, and primary literature (3). Study characteristics and outcomes will be evaluated and presented in standardized reports, including preliminary conclusions on the clinical relevance and practice recommendations (4). The multidisciplinary expert panel will discuss the reports and will either adopt or adjust the conclusions (5). Practice recommendations will be integrated in clinical decision support systems and published (6). The results of the evaluated drug-disease interactions will remain up-to-date by screening new risk information, periodic literature review, and (re)assessments initiated by health care providers. Actionable Recommendations: The practice recommendations will result in advices for specific DDSI. The content and considerations of these DDSIs will be published and implemented in all Clinical Decision Support Systems in the Netherlands. Discussion: The recommendations result in professional guidance in the context of individual patient care. The professional will be supported in the decision making in concerning pharmacotherapy for the treatment of a medical problem, and the clinical risks of the proposed medication in combination with specific diseases

    Meta-analysis of the clinical performance of commercial SARS-CoV-2 nucleic acid and antibody tests up to 22 August 2020

    Get PDF
    Background: Reliable testing for SARS-CoV-2 is key for the management of the COVID-19 pandemic. Aim: We estimate diagnostic accuracy for nucleic acid and antibody tests 5 months into the COVID-19 pandemic, and compare with manufacturer-reported accuracy. Methods: We reviewed the clinical performance of SARS-CoV-2 nucleic acid and antibody tests based on 93,757 test results from 151 published studies and 20,205 new test results from 12 countries in the European Union and European Economic Area (EU/ EEA). Results: Pooling the results and considering only results with 95% confidence interval width ≀ 5%, we found four nucleic acid tests, including one pointof- care test and three antibody tests, with a clinical sensitivity ≄ 95% for at least one target population (hospitalised, mild or asymptomatic, or unknown). Nine nucleic acid tests and 25 antibody tests, 12 of them point-of-care tests, had a clinical specificity of ≄ 98%. Three antibody tests achieved both thresholds. Evidence for nucleic acid point-of-care tests remains scarce at present, and sensitivity varied substantially. Study heterogeneity was low for eight of 14 sensitivity and 68 of 84 specificity results with confidence interval width ≀ 5%, and lower for nucleic acid tests than antibody tests. Manufacturer-reported clinical performance was significantly higher than independently assessed in 11 of 32 and four of 34 cases, respectively, for sensitivity and specificity, indicating a need for improvement in this area. Conclusion: Continuous monitoring of clinical performance within more clearly defined target populations is needed.</p
    • 

    corecore