329 research outputs found
Risk factors for musculoskeletal injuries in elite junior tennis players: a systematic review
Item does not contain fulltextThe objective was to systematically review the literature on risk factors and prevention programs for musculoskeletal injuries among tennis players. PubmedMedline, Embase, CINAHL, Cochrane, SportDiscus were searched up to February 2017. Experts in clinical and epidemiological medicine were contacted to obtain additional studies. For risk factors, prospective cohort studies (n > 20) with a statistical analysis for injured and non-injured players were included and studies with a RCT design for prevention programs. Downs&Black checklist was assessed for risk of bias for risk factors. From a total of 4067 articles, five articles met our inclusion criteria for risk factors. No studies on effectiveness of prevention programs were identified. Quality of studies included varied from fair to excellent. Best evidence synthesis revealed moderate evidence for previous injury regardless of body location in general and fewer years of tennis experience for the occurrence of upper extremity injuries. Moderate evidence was found for lower back injuries, a previous back injury, playing >6hours/week and low lateral flexion of the neck for risk factors. Limited evidence was found for male gender as a risk factor. The risk factors identified can assist clinicians in developing prevention-strategies. Further studies should focus on risk factor evaluation in recreational adult tennis players
Anatomy of the inferior extensor retinaculum and its role in lateral ankle ligament reconstruction: a pictorial essay
The inferior extensor retinaculum (IER) is an aponeurotic structure, which is in continuation with the anterior part of the sural fascia. The IER has often been used to augment the reconstruction of the lateral ankle ligaments, for instance in the Broström-Gould procedure, with good outcomes reported. However, its anatomy has not been described in detail and only a few studies are available on this structure. The presence of a non-constant oblique supero-lateral band appears to be important. This structure defines whether the augmentation of the lateral ankle ligaments reconstruction is performed using true IER or only the anterior part of the sural fascia. It is concluded that the use of this structure will have an impact on the resulting ankle stability
Clinical evaluation of a dynamic test for lateral ankle ligament laxity
The dynamic anterior ankle tester (DAAT) has shown a good reliability in testing anterior talar translation in earlier studies. The goal of the present study was first to evaluate the reliability of the DAAT in a clinical setting and second to analyze its ability to detect increased ligament laxity. In 39 patients with unilateral chronic lateral ankle instability, the anterior talar translation of the affected and non-affected side was measured pre and postoperatively using the DAAT, Telos stress radiographs, and the manual anterior drawer test. In contrast to both other tests, the DAAT was not able to accurately detect increased ligament laxity preoperatively or decreased laxity of the affected ankle postoperatively. The DAAT showed a low sensitivity to change (the difference between the mean pre and postoperative value) and a low reliability compared to both other tests. There were no correlations between the three tests. In conclusion, the DAAT showed a low reliability in effectively testing lateral ankle ligament laxity in a clinical setting. This is in contrast to earlier evaluations
High Rates of Return to Sports Activities and Work After Osteotomies Around the Knee: A Systematic Review and Meta-Analysis
© 2017, The Author(s). Background: Knee osteotomies are proven treatment options, especially in younger patients with unicompartmental knee osteoarthritis, for certain cases of chronic knee instability, or as concomitant treatment for meniscal repair or transplantation surgery. Presumably, these patients wish to stay active. Data on whether these patients return to sport (RTS) activities and return to work (RTW) are scarce. Objectives: Our aim was to systematically review (1) the extent to which patients can RTS and RTW after knee osteotomy and (2) the time to RTS and RTW. Methods: We systematically searched the MEDLINE and Embase databases. Two authors screened and extracted data, including patient demographics, surgical technique, pre- and postoperative sports and work activities, and confounding factors. Two authors assessed methodological quality. Data on pre- and postoperative participation in sports and work were pooled. Results: We included 26 studies, involving 1321 patients (69% male). Mean age varied between 27 and 62 years, and mean follow-up was 4.8 years. The overall risk of bias was low in seven studies, moderate in ten studies, and high in nine studies. RTS was reported in 18 studies and mean RTS was 85%. Reported RTS in studies with a low risk of bias was 82%. No studies reported time to RTS. RTW was reported in 14 studies; mean RTW was 85%. Reported RTW in studies with a low risk of bias was 80%. Time to RTW varied from 10 to 22 weeks. Lastly, only 15 studies adjusted for confounders. Conclusion: Eight out of ten patients returned to sport and work after knee osteotomy. No data were available on time to RTS. A trend toward performing lower-impact sports was observed. Time to RTW varied from 10 to 22 weeks, and almost all patients returned to the same or a higher workload
Design and Preliminary Evaluation of a Stiff Steerable Cutter for Arthroscopic Procedures
This article describes a novel and simple shaft actuated tip articulation (SATA) mechanism that allows arthroscopic instruments to articulate while remaining stiff. Since the SATA mechanism requires only independent rotation of two tubes for hinge articulation, cables, gears, or other internal components that are normally found in steerable endoscopic instruments become obsolete. The SATA mechanism was integrated in a new steerable cutter prototype and tested. Early user, mechanical strength and cadaver experiments were performed that indicate that this first prototype withstands an axial and sideways force of 100 N and 20 N, that trained users can (dis)assemble the instrument in less than 1.5 min and that a surgeon is able to reach all important locations on the menisci
Large variation in use of patient-reported outcome measures: A survey of 188 foot and ankle surgeons
Background: There is an increasing interest in the use of patient reported outcome measures (PROMs). However, there is a large variety of PROMs and a lack of consensus regarding preference for their use. Aim of this study is to determine how often PROMS are used for foot and ankle disorders, for what purpose PROMs are used, and what the preferences of the foot and ankle surgeons are, when choosing a PROM to use.Methods: Members of the Ankleplatform Study Group-Science of Variation Collaborative were invited to participate in this survey by email. The online survey consisted of six questions on the use and preferences regarding foot and ankle PROMs.Results: 188 participants completed the questionnaire. Of the respondents 17% reported not to use PROMs, 72% stated to use PROMS for research, 39% routinely for patient care and 34% for registration or quality assessment. The respondents were familiar with 30 different outcome measures, of which 20 were PROMs. One of the excluded outcome measures, the AOFAS Hindfoot scale was most commonly reported as preferred outcome measure. FAOS and MOXFQ were the preferred PROMs, reported by 9.7% of the surgeons. Subsequently followed by the FFI (4.3%), the FAAM (3.7%) and the VAS-FA (3.7%).Conclusions: A large majority of the foot and ankle surgeons uses PROMs. The AOFAS hindfoot scale is mentioned as the most preferred outcome measure, while in fact this is not a PROM. Of the twenty different PROMs mentioned in this study, most reported were the FAOS and MOXFQ both supported by only 9.7% of the surgeons. For proper comparison between patients in clinical practice and research, consensus is needed on which easy-to-use PROM with adequate clinimetric properties should be used. Therefore more evidence in the field of clinimetrics of foot and ankle outcome measures is needed. (C) 2017 Published by Elsevier Ltd on behalf of European Foot and Ankle Society
The ANKLE TRIAL (ANKLE treatment after injuries of the ankle ligaments): what is the benefit of external support devices in the functional treatment of acute ankle sprain? : a randomised controlled trial
<p>Abstract</p> <p>Background</p> <p>Acute lateral ankle ligament injuries are very common problems in present health care. Still there is no hard evidence about which treatment strategy is superior. Current evidence supports the view that a functional treatment strategy is preferable, but insufficient data are present to prove the benefit of external support devices in these types of treatment. The hypothesis of our study is that external ankle support devices will not result in better outcome in the treatment of acute ankle sprains, compared to a purely functional treatment strategy. Overall objective is to compare the results of three different strategies of functional treatment for acute ankle sprain, especially to determine the advantages of external support devices in addition to functional treatment strategy, based on balance and coordination exercises.</p> <p>Methods/design</p> <p>This study is designed as a randomised controlled multi-centre trial with one-year follow-up. Adult and healthy patients (N = 180) with acute, single sided and first inversion trauma of the lateral ankle ligaments will be included. They will all follow the same schedule of balancing exercises and will be divided into 3 treatment groups, 1. pressure bandage and tape, 2. pressure bandage and brace and 3. no external support. Primary outcome measure is the Karlsson scoring scale; secondary outcomes are FAOS (subscales), number of recurrent ankle injuries, Visual Analogue Scales of pain and satisfaction and adverse events. They will be measured after one week, 6 weeks, 6 months and 1 year.</p> <p>Discussion</p> <p>The ANKLE TRIAL is a randomized controlled trial in which a purely functional treated control group, without any external support is investigated. Results of this study could lead to other opinions about usefulness of external support devices in the treatment of acute ankle sprain.</p> <p>Trial registration</p> <p>Netherlands Trial Register (NTR): <a href="http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2151">NTR2151</a></p
Probing forces of menisci: what levels are safe for arthroscopic surgery
Purpose To facilitate effective learning, feedback on performance during arthroscopic training is essential. Less attention has been paid to feedback on monitoring safe handling of delicate tissues such as meniscus. The goal is to measure in vitro probing forces of menisci and compare them with a theoretical maximum probing force (TMPF). Method Menisci samples of ten cadavers were mounted on force platforms to measure probing forces up to 20 N in three directions. Nineteen subjects participated: six novices (experience 60 arthroscopies), and three faculty (>250 a year). All had to perform three tasks on each meniscus sample with an arthroscopic probe: push three times on the superior meniscal surface, perform one continuous run on the superior meniscal surface, and push three times on the inferior meniscal surface. The absolute maximum probing force (AMPF) was determined for each condition. A multivariable linear regression analysis was performed to assess the influence of experience on the force magnitude (P < 0.05). AMPFs were compared to the TMPF (estimated to be 8.5 N). Results The AMPF of the push task was on average 2.8 N (standard deviation (SD) of 0.8 N), of the continuous run task 2.5 N (SD 0.9 N), and of the pull task 3.9 N (SD 2.0 N). Significant difference was present between experts and novices (P < 0.05). The AMPFs are in the same order of magnitude as the TMPF. Conclusion The results indicate the necessity of using a safety level for tissue manipulation when training arthroscopy and a value for is magnitude.Biomechanical EngineeringMechanical, Maritime and Materials Engineerin
- …