131 research outputs found

    Medicinal Plants of Chile: Evaluation of their Anti-Trypanosoma cruzi Activity

    Get PDF
    San Martin, J (San Martin, Jose). Univ Talca, Inst Biol Vegetal & Biotecnol, Talca, ChileThe extracts of several plants of Central Chile exhibited anti-Trypanosoma cruzi trypomastigotes activity. Most active extracts were those obtained from Podanthus ovatifolius, Berberis microphylla, Kageneckia oblonga, and Drimys winteri. The active extract of Drimys winteri (IC50 51.2 mu g/mL) was purified and three drimane sesquiterpenes were obtained: polygodial, drimenol, and isodrimenin. Isodrimenin and drimenol were found to be active against the trypomastigote form of T cruzi with IC50 values of 27.9 and 25.1 mu M, respectivel

    Response of a Li-glass/multi-anode photomultiplier detector to collimated thermal-neutron beams

    Get PDF
    The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved perpendicularly through the neutron beams in 0.5 to 1.0 mm horizontal and vertical steps. Scintillation was detected in an 8 X 8 pixel multi-anode photomultiplier tube on an event-by-event basis. In general, several pixels registered large signals at each neutron-beam location. The number of pixels registering signal above a set threshold was investigated, with the maximization of the single-hit efficiency over the largest possible area of the detector as the primary goal. At a threshold of ~50% of the mean of the full-deposition peak, ~80% of the events were registered in a single pixel, resulting in an effective position resolution of ~5 mm in X and Y. Lower thresholds generally resulted in events demonstrating higher pixel multiplicities, but these events could also be localized with ~5 mm position resolution.Comment: 23 pages, 8 figure

    Distributive politics and regional development: assessing the territorial distribution of Turkey’s public investment

    Get PDF
    Turkey is often perceived as a country with low bureaucratic capacity and prone to political manipulation and ‘pork-barrel’. This article tests whether this is the case, by analysing the extent to which politics, rather than equity and efficiency criteria, have determined the geographical allocation of public investment across the 81 provinces of Turkey between 2005 and 2012. The results show that although the Turkish government has indeed channelled public expenditures to reward its core constituencies, socioeconomic factors remained the most relevant predictors of investment. Moreover, in contrast to official regional development policy principles, we uncover the concentration of public investment in areas with comparatively higher levels of development. We interpret this as the state bureaucracy’s intentional strategy of focussing on efficiency by concentrating resources on ‘the better off among the most in need’

    Search for a dark photon in the π0e+eγ\pi^0 \to e^+e^-\gamma decay

    Full text link
    The presently world largest data sample of pi0 --> gamma e+e- decays containing nearly 5E5 events was collected using the WASA detector at COSY. A search for a dark photon U produced in the pi0 --> gamma U --> gamma e+e- decay from the pp-->pp\pi^0 reaction was carried out. An upper limit on the square of the U-gamma mixing strength parameter epsilon^2 of 5e-6 at 90% CL was obtained for the mass range 20 MeV <M_U< 100 MeV. This result together with other recent experimental limits significantly reduces the M_U vs. \epsilon^2 parameter space preferred by the measured value of the muon anomalous magnetic moment.Comment: 16 pages, 8 figures; improved analysis extending the exclusion region to 20 MeV<M_U< 100 MeV; implemented changes requested by referee

    Feasibility studies of time-like proton electromagnetic form factors at PANDA at FAIR

    Get PDF
    Simulation results for future measurements of electromagnetic proton form factors at \PANDA (FAIR) within the PandaRoot software framework are reported. The statistical precision with which the proton form factors can be determined is estimated. The signal channel pˉpe+e\bar p p \to e^+ e^- is studied on the basis of two different but consistent procedures. The suppression of the main background channel, i.e.\textit{i.e.} pˉpπ+π\bar p p \to \pi^+ \pi^-, is studied. Furthermore, the background versus signal efficiency, statistical and systematical uncertainties on the extracted proton form factors are evaluated using two different procedures. The results are consistent with those of a previous simulation study using an older, simplified framework. However, a slightly better precision is achieved in the PandaRoot study in a large range of momentum transfer, assuming the nominal beam conditions and detector performance

    Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets

    Full text link
    This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their anticipated performance. It precedes the tender and procurement of the magnets and, hence, is subject to possible modifications arising during this process.Comment: 10 pages, 14MB, accepted by FAIR STI in May 2009, editors: Inti Lehmann (chair), Andrea Bersani, Yuri Lobanov, Jost Luehning, Jerzy Smyrski, Technical Coordiantor: Lars Schmitt, Bernd Lewandowski (deputy), Spokespersons: Ulrich Wiedner, Paola Gianotti (deputy

    Response of a Li-glass/multi-anode photomultiplier detector to α-particles from <sup>241</sup>Am

    Get PDF
    The response of a position-sensitive Li-glass scintillator detector to -particles from a collimated ²⁴¹Am source scanned across the face of the detector has been measured. Scintillation light was read out by an 8 x 8 pixel multi-anode photomultiplier and the signal amplitude for each pixel has been recorded for every position on a scan. The pixel signal is strongly dependent on position and in general several pixels will register a signal (a hit) above a given threshold. The effect of this threshold on hit multiplicity is studied, with a view to optimize the single-hit efficiency of the detector

    Measurement of the ηπ+ππ0\eta\to\pi^+\pi^-\pi^0 Dalitz plot distribution

    Full text link
    Dalitz plot distribution of the ηπ+ππ0\eta\to\pi^+\pi^-\pi^0 decay is determined using a data sample of 1.21071.2\cdot 10^7 η\eta mesons from pd3Heηpd\to ^3\textrm{He}\eta reaction at 1 GeV collected by the WASA detector at COSY.Comment: 13 pages, 6 figure
    corecore