9,875 research outputs found

    Motion sickness susceptibility under weightless and hypergravity conditions generated by parabolic flight

    Get PDF
    Motion sickness susceptibility under weightless and hypergravity conditions generated by parabolic fligh

    Precision of the calibration of the AXAF engineering test article (VETA) mirrors

    Get PDF
    Measurements of the VETA encircled energies have been performed at 5 energies within 16 radii ranging from 0.05 to 200 arcseconds. We report here on the analysis of the accuracy of those measurements. A common 'error tree' structure applies, and we present representative numbers for the larger terms. At 0.277, 1.5, and 2.07 keV, and for radii of 3 arcsec and larger, our measurements have estimated 1 sigma errors of 0.6 to 1.5 percent. Effects of measurement statistics and of the VETA test mount limit the accuracy at smaller angles, and modulation by the counter window support structure together with the imperfect position repeatability limit the accuracy for the 0.93 and 2.3 keV energies. We expect to mitigate these limitations when calibrating the complete AXAF flight mirror assembly

    Development of Replacement Heifers using Combinations of Three Forage Types and Feed Supplements (with or without Broiler Litter)

    Get PDF
    The proper management of replacement heifers is an essential component of successful cow/calf operations. The level of management and nutrition applied to replacement heifers as calves and yearlings can impact their subsequent reproductive performance and productivity

    Hydrodynamical simulations of the jet in the symbiotic star MWC 560 III. Application to X-ray jets in symbiotic stars

    Full text link
    In papers I and II in this series, we presented hydrodynamical simulations of jet models with parameters representative of the symbiotic system MWC 560. These were simulations of a pulsed, initially underdense jet in a high density ambient medium. Since the pulsed emission of the jet creates internal shocks and since the jet velocity is very high, the jet bow shock and the internal shocks are heated to high temperatures and should therefore emit X-ray radiation. In this paper, we investigate in detail the X-ray properties of the jets in our models. We have focused our study on the total X-ray luminosity and its temporal variability, the resulting spectra and the spatial distribution of the emission. Temperature and density maps from our hydrodynamical simulations with radiative cooling presented in the second paper are used together with emissivities calculated with the atomic database ATOMDB. The jets in our models show extended and variable X-ray emission which can be characterized as a sum of hot and warm components with temperatures that are consistent with observations of CH Cyg and R Aqr. The X-ray spectra of our model jets show emission line features which correspond to observed features in the spectra of CH Cyg. The innermost parts of our pulsed jets show iron line emission in the 6.4 - 6.7 keV range which may explain such emission from the central source in R Aqr. We conclude that MWC 560 should be detectable with Chandra or XMM-Newton, and such X-ray observations will provide crucial for understanding jets in symbiotic stars.Comment: 10 pages, 12 figures, accepted for publication in ApJ, uses emulateap

    VETA-I x ray test analysis

    Get PDF
    This interim report presents some definitive results from our analysis of the VETA-I x-ray testing data. It also provides a description of the hardware and software used in the conduct of the VETA-I x-ray test program performed at the MSFC x-ray Calibration Facility (XRCF). These test results also serve to supply data and information to include in the TRW final report required by DPD 692, DR XC04. To provide an authoritative compendium of results, we have taken nine papers as published in the SPIE Symposium, 'Grazing Incidence X-ray/EUV Optics for Astronomy and Projection Lithography' and have reproduced them as the content of this report

    Sentinel surveillance of HIV-1 transmitted drug resistance, acute infection and recent infection.

    Get PDF
    BackgroundHIV-1 acute infection, recent infection and transmitted drug resistance screening was integrated into voluntary HIV counseling and testing (VCT) services to enhance the existing surveillance program in San Francisco. This study describes newly-diagnosed HIV cases and characterizes correlates associated with infection.Methodology/principal findingsA consecutive sample of persons presenting for HIV VCT at the municipal sexually transmitted infections (STI) clinic from 2004 to 2006 (N = 9,868) were evaluated by standard enzyme-linked immunoassays (EIA). HIV antibody-positive specimens were characterized as recent infections using a less-sensitive EIA. HIV-RNA pooled testing was performed on HIV antibody-negative specimens to identify acute infections. HIV antibody-positive and acute infection specimens were evaluated for drug resistance by sequence analysis. Multivariable logistic regression was performed to evaluate associations. The 380 newly-diagnosed HIV cases included 29 acute infections, 128 recent infections, and 47 drug-resistant cases, with no significant increases or decreases in prevalence over the three years studied. HIV-1 transmitted drug resistance prevalence was 11.0% in 2004, 13.4% in 2005 and 14.9% in 2006 (p = 0.36). Resistance to non-nucleoside reverse transcriptase inhibitors (NNRTI) was the most common pattern detected, present in 28 cases of resistance (59.6%). Among MSM, recent infection was associated with amphetamine use (AOR = 2.67; p<0.001), unprotected anal intercourse (AOR = 2.27; p<0.001), sex with a known HIV-infected partner (AOR = 1.64; p = 0.02), and history of gonorrhea (AOR = 1.62; p = 0.03).ConclusionsNew HIV diagnoses, recent infections, acute infections and transmitted drug resistance prevalence remained stable between 2004 and 2006. Resistance to NNRTI comprised more than half of the drug-resistant cases, a worrisome finding given its role as the backbone of first-line antiretroviral therapy in San Francisco as well as worldwide. The integration of HIV-1 drug resistance, recent infection, and acute infection testing should be considered for existing HIV/STI surveillance and prevention activities, particularly in an era of enhanced efforts for early diagnosis and treatment

    A comparison of spectral element and finite difference methods using statically refined nonconforming grids for the MHD island coalescence instability problem

    Full text link
    A recently developed spectral-element adaptive refinement incompressible magnetohydrodynamic (MHD) code [Rosenberg, Fournier, Fischer, Pouquet, J. Comp. Phys. 215, 59-80 (2006)] is applied to simulate the problem of MHD island coalescence instability (MICI) in two dimensions. MICI is a fundamental MHD process that can produce sharp current layers and subsequent reconnection and heating in a high-Lundquist number plasma such as the solar corona [Ng and Bhattacharjee, Phys. Plasmas, 5, 4028 (1998)]. Due to the formation of thin current layers, it is highly desirable to use adaptively or statically refined grids to resolve them, and to maintain accuracy at the same time. The output of the spectral-element static adaptive refinement simulations are compared with simulations using a finite difference method on the same refinement grids, and both methods are compared to pseudo-spectral simulations with uniform grids as baselines. It is shown that with the statically refined grids roughly scaling linearly with effective resolution, spectral element runs can maintain accuracy significantly higher than that of the finite difference runs, in some cases achieving close to full spectral accuracy.Comment: 19 pages, 17 figures, submitted to Astrophys. J. Supp

    VETA-1 x ray detection system

    Get PDF
    The alignment and X-ray imaging performance of the Advanced X-ray Astrophysics Facility (AXAF) Verification Engineering Test Article-I (VETA-I) was measured by the VETA-I X-Ray Detection System (VXDS). The VXDS was based on the X-ray detection system utilized in the AXAF Technology Mirror Assembly (TMA) program, upgraded to meet the more stringent requirements of the VETA-I test program. The VXDS includes two types of X-ray detectors: (1) a High Resolution Imager (HRI) which provides X-ray imaging capabilities, and (2) sealed and flow proportional counters which, in conjunction with apertures of various types and precision translation stages, provide the most accurate measurement of VETA-I performance. Herein we give an overview of the VXDS hardware including X-ray detectors, translation stages, apertures, proportional counters and flow counter gas supply system and associated electronics. We also describe the installation of the VXDS into the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF). We discuss in detail the design and performance of those elements of the VXDS which have not been discussed elsewhere; translation systems, flow counter gas supply system, apertures and thermal monitoring system

    Stability of sub-surface oxygen at Rh(111)

    Full text link
    Using density-functional theory (DFT) we investigate the incorporation of oxygen directly below the Rh(111) surface. We show that oxygen incorporation will only commence after nearly completion of a dense O adlayer (\theta_tot = 1.0 monolayer) with O in the fcc on-surface sites. The experimentally suggested octahedral sub-surface site occupancy, inducing a site-switch of the on-surface species from fcc to hcp sites, is indeed found to be a rather low energy structure. Our results indicate that at even higher coverages oxygen incorporation is followed by oxygen agglomeration in two-dimensional sub-surface islands directly below the first metal layer. Inside these islands, the metastable hcp/octahedral (on-surface/sub-surface) site combination will undergo a barrierless displacement, introducing a stacking fault of the first metal layer with respect to the underlying substrate and leading to a stable fcc/tetrahedral site occupation. We suggest that these elementary steps, namely, oxygen incorporation, aggregation into sub-surface islands and destabilization of the metal surface may be more general and precede the formation of a surface oxide at close-packed late transition metal surfaces.Comment: 9 pages including 9 figure files. Submitted to Phys. Rev. B. Related publications can be found at http://www.fhi-berlin.mpg.de/th/paper.htm

    Harvester-Forwarder and Harvester-Yarder Systems for Fuel Reduction Treatments

    Get PDF
    Two harvesting systems were compared for reducing fuel loadings in overstocked conifer stands in eastern Oregon; forest managers also set a high priority on minimizing soil disturbance. Both employed cut-to-length (CTL) harvesters; one used a forwarder and the other a small skyline yarder. Both systems produced very similar and acceptable results in terms of fuels reduction and soil disturbance, but at different stump-to-mill costs: 46/greentonfortheforwardersystemversus46/green ton for the forwarder system versus 80/green ton for the yarder system
    corecore