25 research outputs found

    Dilation of the ascending aorta in Turner syndrome - a prospective cardiovascular magnetic resonance study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The risk of aortic dissection is 100-fold increased in Turner syndrome (TS). Unfortunately, risk stratification is inadequate due to a lack of insight into the natural course of the syndrome-associated aortopathy. Therefore, this study aimed to prospectively assess aortic dimensions in TS.</p> <p>Methods</p> <p>Eighty adult TS patients were examined twice with a mean follow-up of 2.4 ± 0.4 years, and 67 healthy age and gender-matched controls were examined once. Aortic dimensions were measured at nine predefined positions using 3D, non-contrast and free-breathing cardiovascular magnetic resonance. Transthoracic echocardiography and 24-hour ambulatory blood pressure were also performed.</p> <p>Results</p> <p>At baseline, aortic diameters (body surface area indexed) were larger at all positions in TS. Aortic dilation was more prevalent at all positions excluding the distal transverse aortic arch. Aortic diameter increased in the aortic sinus, at the sinotubular junction and in the mid-ascending aorta with growth rates of 0.1 - 0.4 mm/year. Aortic diameters at all other positions were unchanged. The bicuspid aortic valve conferred higher aortic sinus growth rates (p < 0.05). No other predictors of aortic growth were identified.</p> <p>Conclusion</p> <p>A general aortopathy is present in TS with enlargement of the ascending aorta, which is accelerated in the presence of a bicuspid aortic valve.</p

    Thoracic aortopathy in Turner syndrome and the influence of bicuspid aortic valves and blood pressure: a CMR study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p/> <p>To investigate aortic dimensions in women with Turner syndrome (TS) in relation to aortic valve morphology, blood pressure, karyotype, and clinical characteristics.</p> <p>Methods and results</p> <p>A cross sectional study of 102 women with TS (mean age 37.7; 18-62 years) examined by cardiovascular magnetic resonance (CMR- successful in 95), echocardiography, and 24-hour ambulatory blood pressure. Aortic diameters were measured by CMR at 8 positions along the thoracic aorta. Twenty-four healthy females were recruited as controls. In TS, aortic dilatation was present at one or more positions in 22 (23%). Aortic diameter in women with TS and bicuspid aortic valve was significantly larger than in TS with tricuspid valves in both the ascending (32.4 ± 6.7 vs. 26.0 ± 4.4 mm; p < 0.001) and descending (21.4 ± 3.5 vs. 18.8 ± 2.4 mm; p < 0.001) aorta. Aortic diameter correlated to age (R = 0.2 - 0.5; p < 0.01), blood pressure (R = 0.4; p < 0.05), a history of coarctation (R = 0.3; p = 0.01) and bicuspid aortic valve (R = 0.2-0.5; p < 0.05). Body surface area only correlated with descending aortic diameter (R = 0.23; p = 0.024).</p> <p>Conclusions</p> <p/> <p>Aortic dilatation was present in 23% of adult TS women, where aortic valve morphology, age and blood pressure were major determinants of the aortic diameter.</p

    Hemodynamic causes of exercise intolerance in Fontan patients.

    No full text
    Exercise intolerance is frequent among Fontan patients and an important determinant for quality of life. This study investigated the hemodynamic causes of impaired exercise capacity in Fontan patients with particular focus on the influence of stroke volume index (SVI) and heart rate (HR)

    Bosentan Improves Exercise Capacity in Adolescents and Adults After Fontan Operation: The TEMPO (Treatment With Endothelin Receptor Antagonist in Fontan Patients, a Randomized, Placebo-Controlled, Double-Blind Study Measuring Peak Oxygen Consumption) Study.

    No full text
    The Fontan procedure has improved survival in children with functionally univentricular hearts. With time, however, complications such as reduced exercise capacity are seen more frequently. Exercise intolerance is multifactorial, but pulmonary vascular resistance probably plays a crucial role. Elevated pulmonary vascular resistance has been associated with raised levels of endothelin-1, which are common both before and after Fontan operations. Treatment with endothelin-1 receptor antagonists could theoretically improve cardiopulmonary hemodynamics and exercise capacity. The aim of this study was therefore to examine the efficacy and safety of bosentan in Fontan patients
    corecore