35 research outputs found

    Deficiency of triad junction and contraction in mutant skeletal muscle lacking junctophilin type 1

    Get PDF
    In skeletal muscle excitation–contraction (E–C) coupling, the depolarization signal is converted from the intracellular Ca2+ store into Ca2+ release by functional coupling between the cell surface voltage sensor and the Ca2+ release channel on the sarcoplasmic reticulum (SR). The signal conversion occurs in the junctional membrane complex known as the triad junction, where the invaginated plasma membrane called the transverse-tubule (T-tubule) is pinched from both sides by SR membranes. Previous studies have suggested that junctophilins (JPs) contribute to the formation of the junctional membrane complexes by spanning the intracellular store membrane and interacting with the plasma membrane (PM) in excitable cells. Of the three JP subtypes, both type 1 (JP-1) and type 2 (JP-2) are abundantly expressed in skeletal muscle. To examine the physiological role of JP-1 in skeletal muscle, we generated mutant mice lacking JP-1. The JP-1 knockout mice showed no milk suckling and died shortly after birth. Ultrastructural analysis demonstrated that triad junctions were reduced in number, and that the SR was often structurally abnormal in the skeletal muscles of the mutant mice. The mutant muscle developed less contractile force (evoked by low-frequency electrical stimuli) and showed abnormal sensitivities to extracellular Ca2+. Our results indicate that JP-1 contributes to the construction of triad junctions and that it is essential for the efficiency of signal conversion during E–C coupling in skeletal muscle

    Lipomatous Pseudohypertrophy of the Pancreas Taking the Form of Huge Massive Lesion of the Pancreatic Head

    Get PDF
    A 70-year-old woman presented with hypogastric pain. Computed tomography and magnetic resonance imaging revealed a retroperitoneal tumor 18.0 cm in diameter with fatty tissue density, ventrally compressing the pancreatic head. We suspected a well-differentiated liposarcoma compressing the pancreas. At laparotomy, the tumor mass was the size of an infant's head; its center was located in the area corresponding to the pancreatic uncus. It was continuous with the pancreatic parenchyma through a poorly demarcated border, and we resected as much of the tumor mass as possible while conserving the pancreatic capsule. Histopathological examination indicated lipomatous pseudohypertrophy of the pancreas with proliferation of mature fatty tissue as the main constituent. At the periphery, islands of acinar tissue were retained among the fatty infiltration, which also contained branches of the pancreatic duct and islets of Langerhans. Previous reports have stated that this disorder only causes fatty replacements throughout the pancreas or in the pancreatic body and tail; however, in this patient, imaging and macroscopic examination revealed no fatty replacements in the pancreatic body and tail. We report this case, which we consider extremely rare, along with a brief review of the literature

    Fluorescent Cytochemical Detection of Polyphosphates Associated with Human Platelets

    No full text
    Polyphosphate (polyP) is released from activated platelets and activates the intrinsic coagulation pathway. However, polyP may also be involved in various pathophysiological functions related to platelets. To clarify these functions, we established a cytochemical method to reproducibly visualize polyP in platelets. Platelets obtained from healthy non-smoking donors were suspended in phosphate-buffered saline and quickly immobilized on glass slides using a Cytospin. After fixation and membrane permeabilization, platelets were treated with 4′,6- diamidino-2-phenylindole (DAPI) and examined using a fluorescence microscope with a blue-violet excitation filter block (BV-2A). Fixed platelets were also subjected to immunocytochemical examination to visualize serotonin distribution. Under the optimized conditions for polyP visualization, immobilized platelets were fixed with 10% neutral-buffered formalin for 4 h or longer and treated with DAPI at a concentration of 10 µg/mL in 0.02% saponin- or 0.1% Tween-20-containing Hanks balanced salt solution as a permeabilization buffer for 30 min at room temperature (22–25 °C). Based on the results obtained by using activated platelets, treatment with alkaline phosphatases, and serotonin release, the DAPI+ targets were identified as polyP. Therefore, this cytochemical method is useful for determining the amount and distribution of polyP in platelets

    Platelet Adhesion on Commercially Pure Titanium Plates in Vitro II. Immunofluorescence Visualization of PDGF-B, TGFβ1, and PPARγ Released from Activated Adherent Platelets

    No full text
    Recent progress in the industrial development of dental implants has improved their surface bio-affinity, while clinical implantologists attempt to improve it through coating with various compounds, including platelet-rich plasma (PRP) in clinical settings. However, it is poorly understood how PRP acts on titanium surfaces. To validate this surface modification method and demonstrate how platelet-derived soluble biomolecules released from the activated adherent platelets act on plain, commercially pure-titanium (cp-Ti) plates, we evaluated the distribution of biomolecules by immunofluorescence. PPARγ, PDGF-B, and TGFβ1 were similarly released at immunofluorescence levels from activated adherent platelets, retained in the surrounding extra-platelet spaces for a while, and did not immediately diffuse away to distant spaces. Exogenously added CaCl2 augmented release and retention of those biomolecules along with activation and aggregation. Taken together with our previous data regarding platelet adhesion, these findings suggest that especially when treated with CaCl2, platelets immediately adhere on cp-Ti plates to release their stored biomolecules in the absence of plasma proteins and that these biomolecules do not diffuse away, but stay longer in extra-platelet spaces around the platelets by newly formed, immature fibrin fiber fragments. Consequently, these retained biomolecules are anticipated to cooperatively stabilize implants by stimulating alveolar bone regeneration and integration

    Platelet adhesion on commercially pure titanium plates in vitro I: effects of plasma components and involvement of the von Willebrand factor and fibronectin

    No full text
    Abstract Background Platelet-rich plasma (PRP) is widely used in regenerative dentistry. Furthermore, it is often applied in the pretreatment of titanium implants to improve their surface bioaffinity and initial stability. However, effects of PRP application on implant surface at cellular and molecular levels remain poorly understood. Therefore, we examined platelet adhesion on commercially pure titanium (cp-Ti) plates, with a particular focus on fibrinogen (FGN), von Willebrand factor (vWF), and fibronectin (FN), in the presence or absence of plasma components. Methods Citrated blood samples were obtained from six healthy male volunteers, and pure-PRP (P-PRP) and pure platelet suspensions in phosphate-buffered saline (PBS) were prepared. Platelet adhesion on cp-Ti plate surface was evaluated by phalloidin staining and tetrazolium dye assay. Distribution of FGN, vWF, FN, albumin, CD62P, and CD63 was examined by immunocytochemical analysis. Results Platelets in PBS suspensions rapidly and time-dependently adhered to cp-Ti plate surface, but this adhesion was substantially disturbed by the presence of plasma components. FGN was most preferably adsorbed regardless of the presence or absence of plasma components, while vWF and FN showed greater accumulation on platelet adhesion area. Conclusions Although FGN is rapidly and abundantly adsorbed on cp-Ti plate surface, vWF and FN function as major platelet adhesion molecules in citrated blood samples. After pretreatment with P-PRP, however, platelets adhered to cp-Ti much less efficiently. Therefore, P-PRP pretreatment might not directly contribute to surface functionalization, initial stabilization, and osseointegration of machined or similar types of implants

    Evidence for Contamination of Silica Microparticles in Advanced Platelet-Rich Fibrin Matrices Prepared Using Silica-Coated Plastic Tubes

    No full text
    Platelet-rich fibrin (PRF) therapy has been widely applied in regenerative dentistry, and PRF preparation has been optimized to efficiently form fibrin clots using plain glass tubes. Currently, a shortage of commercially available glass tubes has forced PRF users to utilize silica-coated plastic tubes. However, most plastic tubes are approved by regulatory authorities only for diagnostic use and remain to be approved for PRF therapy. To clarify this issue, we quantified silica microparticles incorporated into the PRF matrix. Blood samples were collected into three different brands of silica-containing plastic tubes and were immediately centrifuged following the protocol for advanced-PRF (A-PRF). Advanced-PRF-like matrices were examined using a scanning electron microscope (SEM), and silica microparticles were quantified using a spectrophotometer. Each brand used silica microparticles of specific size and appearance. Regardless of tube brands and individual donors, significant, but not accidental, levels of silica microparticles were found to be incorporated into the A-PRF-like matrix, which will be consequently incorporated into the implantation sites. Presently, from the increasing data for cytotoxicity of amorphous silica, we cannot exclude the possibility that such A-PRF-like matrices negatively influence tissue regeneration through induction of inflammation. Further investigation should be performed to clarify such potential risks

    Distribution and quantification of activated platelets in platelet-rich fibrin matrices.

    No full text
    Platelet-rich fibrin (PRF) has been widely applied in regenerative therapy owing to its simple preparation protocol. To date, the original protocol for preparing leukocyte-rich (L)-PRF has been modified to produce derivatives such as advanced (A)-PRF, concentrated growth factors (CGF), and horizontal (H)-PRF. However, these derivatives have not been rigorously compared to explore possible differences. We previously developed and validated a nondestructive near-infrared (NIR) imaging method to quantitatively examine the platelet distribution in PRF matrices. To further evaluate the characteristics of platelets in PRF, we herein examined the distribution of activated platelets. Four types of PRF matrices were prepared under different centrifugal conditions from blood samples obtained from the same healthy donors. After fixation and compression, the matrices were stained immunohistochemically without sectioning and visualized using an NIR imager. Qualitative morphological analysis revealed that whole platelets were distributed widely and homogeneously in H-PRF and A-PRF, but localized along the distal tube surface in L-PRF and CGF. Activated platelets were distributed as were whole platelets in A-PRF, L-PRF, and CGF, but localized mainly in the "buffy coat" region in H-PRF. Quantitative analysis revealed that there was no significant difference in the ratio of activated to whole platelets between PRF derivatives. These findings suggest that platelet activation is similarly induced in fibrin matrices regardless of centrifugal speed or rotor angulation. However, only the H-PRF group was distinguishable from the other PRF derivatives in terms of activated platelet distribution
    corecore