23 research outputs found
Clinical Management of Implant Prostheses in Patients with Bruxism
There is general agreement that excessive stress to the bone-implant interface may result in implant overload and failure. Early failure of the implant due to excessive loading occurs shortly after uncovering the implant. Excess load on a final restoration after successful implant integration can result in physical failure of the implant structure. Many clinicians believe that overload of dental implants is a risk factor for vertical peri-implant bone loss and/or may be detrimental for the suprastructure in implant prostheses. It has been documented that occlusal parafunction, such as, bruxism (tooth grinding and clenching) affects the outcome of implant prostheses, but there is no evidence for a causal relation between the failures and overload of dental implants. In spite of this lack of evidence, often metal restorations are preferred instead of porcelain for patients in whom bruxism is presumed on the basis of tooth wear. The purpose of this paper is to discuss the importance of the occlusal scheme used in implant restorations for implant longevity and to suggest a clinical approach and occlusal materials for implant prostheses in order to prevent complications related to bruxism
Clinical application of removable partial dentures using thermoplastic resin—Part I: Definition and indication of non-metal clasp dentures
AbstractThis position paper proposes a definition and naming standard for removable partial dentures (RPDs) using thermoplastic resin, and presents a guideline for clinical application. A panel of 14 experts having broad experience with clinical application of RPDs using thermoplastic resin was selected from members of the Japan Prosthodontic Society. At a meeting of the panel, “non-metal clasp denture” was referred as the generic name of RPDs with retentive elements (resin clasps) made of thermoplastic resin. The panel classified non-metal clasp dentures into two types: one with a flexible structure that lacks a metal framework and the other having a rigid structure that includes a metal framework. According to current prosthetic principles, flexible non-metal clasp dentures are not recommended as definitive dentures, except for limited cases such as patients with a metal allergy. Rigid non-metal clasp dentures are recommended in cases where patients will not accept metal clasps for esthetic reasons. Non-metal clasp dentures should follow the same design principles as conventional RPDs using metal clasps
Clinical application of removable partial dentures using thermoplastic resin. Part II: Material properties and clinical features of non-metal clasp dentures
This position paper reviews physical and mechanical properties of thermoplastic resin usedfor non-metal clasp dentures, and describes feature of each thermoplastic resin in clinicalapplication of non-metal clasp dentures and complications based on clinical experience ofexpert panels. Since products of thermoplastic resin have great variability in physical andmechanical properties, clinicians should utilize them with careful consideration of thespecific properties of each product. In general, thermoplastic resin has lower color-stabilityand higher risk for fracture than polymethyl methacrylate. Additionally, the surface ofthermoplastic resin becomes roughened more easily than polymethyl methacrylate. Studiesrelated to material properties of thermoplastic resin, treatment efficacy and follow-up areinsufficient to provide definitive conclusions at this time. Therefore, this position papershould be revised based on future studies and a clinical guideline should be provided
Lip muscle training improves obstructive sleep apnea and objective sleep: a case report
The present study assessed the potential of lip muscle training for
improving sleep. A patient with heavy snoring, daytime sleepiness and dry mouth
underwent lip muscle training. Lip closure force LCFmax increased by 67.3% and LCFmin by
152% post-training. AHI decreased from 12.2 to 3.9 events/h by reducing hypopneic
episodes. TST, sleep stage N3 and REM sleep increased, and WASO, sleep stage N1, and AI
decreased. The patient switched from mouth to nose breathing during sleep and stopped
snoring. Improved LCF, by moving the tongue into the anterior-superior oral cavity, may
increase upper airway space and reduce the hypopnea index
Lip muscle training improves obstructive sleep apnea and objective sleep: a case report
The present study assessed the potential of lip muscle training for
improving sleep. A patient with heavy snoring, daytime sleepiness and dry mouth
underwent lip muscle training. Lip closure force LCFmax increased by 67.3% and LCFmin by
152% post-training. AHI decreased from 12.2 to 3.9 events/h by reducing hypopneic
episodes. TST, sleep stage N3 and REM sleep increased, and WASO, sleep stage N1, and AI
decreased. The patient switched from mouth to nose breathing during sleep and stopped
snoring. Improved LCF, by moving the tongue into the anterior-superior oral cavity, may
increase upper airway space and reduce the hypopnea index