6 research outputs found

    Carotid CT angiography: comparison of image quality for left versus right arm injections

    No full text
    WOS: 000294197400002PubMed ID: 20698005PURPOSE To evaluate the differences in image quality of carotid computed tomographic angiography (CTA) of patients injected with contrast material in their right arms versus patients injected with contrast material in their left arms. MATERIALS AND METHODS Patients who had cerebrovascular accidents and subsequently underwent CTA were included in the study. Contrast material was injected into the right arms of 44 patients and into the left arms of 46 patients. Source images of a total of 90 CTAs were retrospectively evaluated for perivenous streak artifacts and contrast material reflux into the veins of the neck and upper thorax. After adjusting for differences in gender, the relationship between the injection site and the intensity of perivenous streak artifacts and venous reflux was determined. RESULTS Perivenous streak artifacts and venous reflux were demonstrated in patients who underwent either right or left arm injections. However, the intensity of perivenous streak artifacts was stronger in patients who were injected with contrast material in the left arm. Venous reflux into the neck and upper thorax veins was also more severe and more frequent with left arm injections. A decreased retrosternal distance facilitated reversed flow into the veins when the left arm injection was used. CONCLUSION Perivenous beam hardening streak artifacts and venous reflux could not be prevented with right or left arm injections. However, patients who were injected with contrast material in their right arms showed fewer artifacts, thus allowing for better quality images on CTA

    Thyroid Function and Ultrasonography Abnormalities in Lithium-Treated Bipolar Patients: A Cross-sectional Study with Healthy Controls

    No full text
    WOS: 000404296300004PubMed ID: 28680307Introduction: Lithium has many effects on thyroid physiology. Although these side effects have been known for a long time, large sample studies of lithium-treated patients using ultrasonography are lacking. The aim of this study is to investigate the detailed thyroid mor-phologies, hormone levels, and antibodies of lithium-treated patients compared with healthy controls. Methods: This cross-sectional study involved 84 lithium-treated patients with bipolar disorder and 65 gender and age similar controls who had never been exposed to lithium. Subjects between 18 and 65 years of age were eligible for the study. Venous blood samples were acquired to determine the levels of free thyroxine (fT4), thyroid stimulating hormone (TSH), and thyroid antibodies; also, ultrasonographic examinations of the patients' thyroid glands were performed. Results: There were no statistically significant differences in smoking habits, known thyroid disease, thyroid medication use, familial thyroid disease, fT4 level, autoimmunity, thyroid nodule presence, or Hashimoto's thyroiditis between the lithium and control groups. The median TSH level and thyroid volume were significantly higher in the lithium group. In the lithium group, 14 cases (16.7%) of hypothyroidism, seven cases (8.3%) of subclinical hypothyroidism, and one case (1.2%) of subclinical hyperthyroidism were defined; in the control group, seven cases (10.8%) of hypothyroidism and two cases (3.1%) of subclinical hyperthyroidism were defined. Thyroid dysfunction, goiter, parenchymal abnormality, ultrasonographically defined thyroid abnormality, and thyroid disorder were found to be more prevalent in the lithium group. 90% of patients with goiter and 74.3% of patients with ultrasonographic pathologies were euthyroid. Conclusion: It is important to note that 90% of the patients with goiter were euthyroid. This indicates that monitoring by blood test alone is insufficient. The prevalence rates of 47.6% for goiter and 83.3% for ultrasonographic pathology demonstrate that ultasonographic follow-up may be useful in lithium-treated patients. To determine whether routine ultrasonographic examination is necessary, large sample prospective studies are necessary due to the limitations of this study.Ege University Scientific Research Project Grant; Psychiatric Association of TurkeyThis study was supported by Ege University Scientific Research Project Grant and Psychiatric Association of Turkey

    Hepatic and splenic sonographic and sonoelastographic findings in pulmonary arterial hypertension

    No full text
    Ozbek, Suha Sureyya/0000-0002-3351-4150; orman, mehmet/0000-0003-3544-9329WOS:000632857500012PubMed: 32660202Purpose: The aim of this study was to evaluate the associations of sonographic and sonoelastographic parameters with clinical cardiac parameters, as well as to assess their value in predicting survival in patients with pulmonary arterial hypertension (PAH). Methods: Thirty-six patients with PAH and normal liver function were prospectively enrolled in this prospective study along with 26 healthy controls, all of whom underwent ultrasound and point shear wave elastography examinations. Additionally, the portal vein pulsatility index (PVPI), inferior vena cava collapsibility index, and clinical cardiac variables were obtained in PAH patients. The values of hepatic (LVs) and splenic shear wave velocity (SVs) were compared between PAH patients and controls. The relationships between all sonographic and clinical parameters in the PAH patients were analyzed. Furthermore, their prognostic value in predicting survival was investigated. Results: LV, values in PAH patients (median, 1.62 m/s) were significantly higher than in controls (median, 0.99 m/s), while no significant difference was observed in SVs values. Patients with higher grades of tricuspid regurgitation (TR) had significantly different values of PVPI (P=0.010) and sonoelastographic parameters (P<0.001 for LVs and P=0.004 for SVs) compared to those with less severe TR. Tricuspid annular plane systolic excursion values were the only investigated parameter found to be associated with survival (hazard ratio, 0.814; 95% confidence interval, 0.694 to 0.954; P=0.011). Conclusion: Our results demonstrated a direct association between cardiac congestion (i.e., the severity of TR) and liver stiffness, which should be kept in mind during the assessment of fibrosis in patients with PAH

    Variable sonographic spectrum of parathyroid adenoma with a novel ultrasound finding: dual concentric echo sign

    No full text
    WOS: 000355378000002PubMed ID: 26052562Aims: To review the detailed gray-scale and Doppler ultrasonography features of histologically proven parathyroid adenomas (PAs) evaluated with high-end ultrasonography devices and to present a novel ultrasonography finding called the dual concentric echo sign in PA with histopathologic correlation which was encountered during detailed analysis. Material and methods: Fifty-six PAs with histopathological result were enrolled. The longest dimension, shape, distance to skin surface, internal echo and Doppler US features obtained with high-end US devices were evaluated. Results: PAs had variable range of shape including oval, irregular, fusiform, lobulated, crescent-shaped, and nodular configuration. In nine patients the lesions were shown to have cystic components and calcifications were seen in four cases. Dual concentric echo sign was detected in 18% PAs. Histological reevaluation of this subgroup demonstrated significantly increased edema (p<0.01), and ectatic vessels (p=0.02) in the central part of the lesion compared to the rest of the PAs. Conclusions: The results of the study led to the conclusion that PAs have variable gray-scale and Doppler findings. Typical sonographic features like ovoid shape, homogeneously hypoechoic pattern may not be present in all PAs. Dual concentric echo sign which is a novel sonographic pattern may be suggestive of a PA

    Variable sonographic spectrum of parathyroid adenoma with a novel ultrasound finding: dual concentric echo sign

    No full text
    Abstract Aims: To review the detailed gray-scale and Doppler ultrasonography features of histologically proven parathyroid adenomas (PAs) evaluated with high-end ultrasonography devices and to present a novel ultrasonography finding called the dual concentric echo sign in PA with histopathologic correlation which was encountered during detailed analysis. Material and methods: Fifty-six PAs with histopathological result were enrolled. The longest dimension, shape, distance to skin surface, internal echo and Doppler US features obtained with high-end US devices were evaluated. Results: PAs had variable range of shape including oval, irregular, fusiform, lobulated, crescent-shaped, and nodular configuration. In nine patients the lesions were shown to have cystic components and calcifications were seen in four cases. Dual concentric echo sign was detected in 18% PAs. Histological reevaluation of this subgroup demonstrated significantly increased edema (p&lt;0.01), and ectatic vessels (p=0.02) in the central part of the lesion compared to the rest of the PAs. Conclusions: The results of the study led to the conclusion that PAs have variable gray-scale and Doppler findings. Typical sonographic features like ovoid shape, homogeneously hypoechoic pattern may not be present in all PAs. Dual concentric echo sign which is a novel sonographic pattern may be suggestive of a PA

    Is overactive bladder microvasculature disease a component of systemic atheroscleorosis?

    No full text
    WOS: 000443777500022PubMed ID: 29140571Aims: To evaluate the relationship between overactive bladder (OAB) and systemic atherosclerosis in a cohort of women. Methods: In this case-control study, we assessed atherosclerosis indicators, such as Framingham risk scores and carotid and femoral artery intima-media thickness, and evaluated possible bladder wall responses to atherosclerosis using endovaginal color Doppler ultrasound and the detection of urinary cytokines in women with OAB and in controls. Quantitative assessment of blood perfusion at the bladder neck was performed using a method that allows for the dynamic monitoring of flow in a predefined region of interest at every point of the cardiac cycle. The independent samples t-test was used to evaluate the relationship between OAB and the atherosclerotic findings when parametric conditions were met, and the Mann-Whitney U test was used when parametric conditions were not met. Kendall's Tau was used to assess the correlation between OAB severity and the atherosclerotic variables. P < 0.05 was considered statistically significant. Results: There were 74 OAB patients and 73 controls; in total, 147 women were evaluated. We found that all atherosclerosis indicators were significantly associated with OAB and that there was a significant relationship between OAB and decreased bladder neck perfusion. Additionally, there were correlations of OAB severity with systemic atherosclerosis and impaired vascular perfusion of the bladder. Conclusions: Decreased perfusion at the bladder neck, the Framingham scores in severe OAB, and the correlation between them suggest that OAB microvascular disease may be a component of systemic atherosclerosis rather than a separate process
    corecore