535 research outputs found
Magnetic induction mapping of magnetite chains in magnetotactic bacteria at room temperature and close to the Verwey transition using electron holography
Off-axis electron holography in the transmission electron microscope is used to record magnetic induction maps of closely spaced magnetite crystals in magnetotactic bacteria at room temperature and after cooling the sample using liquid nitrogen. The magnetic microstructure is related to the morphology and crystallography of the particles, and to interparticle interactions. At room temperature, the magnetic signal is dominated by interactions and shape anisotropy, with highly parallel and straight field lines following the axis of each chain of crystals closely. In contrast, at low temperature the magnetic induction undulates along the length of the chain. This behaviour may result from a competition between interparticle interactions and an easy axis of magnetisation that is no longer parallel to the chain axis. The quantitative nature of electron holography also allows the change in magnetisation in the crystals with temperature to be measured
Magnetic characterization of synthetic titanomagnetites: Quantifying the recording fidelity of ideal synthetic analogs
A series of four synthetic basalts comprising titanomagnetite (Fe3-xTixO4) grains of varied size and titanium content have been produced by a glass-ceramic method. Complementary characterization techniques of X-ray diffractometry, secondary electron microscopy, and transmission electron microscopy (TEM) demonstrate the reaction product composition consisted of mainly Fe3-xTixO4, pyroxene hedenbergite, fayalite, and SiO2. The samples exhibit bimodal distributions of larger (<2 ”m) and smaller Fe3-xTixO4 particles (<50 nm in diameter), the latter found inside pyroxene crystals, as well as the sporadic occurance of dendritic Fe3-xTixO4 structures. Magnetic measurements show their bulk characteristics fall into two groups: Ti-rich titanomagnetite samples with varying Ti content; and near-stoichiometric magnetite. The TEM technique of off-axis electron holography allowed for visualization of the magnetic behavior of the synthetic Fe3-xTixO4 grains. Energy dispersive X-ray analysis and off-axis electron holography confirmed the small Fe3-xTixO4 grains (<50 nm) confined within glassy pyroxene regions to be Fe-rich and single domain, carrying strong magnetic signals, compared to the relatively magnetically weak larger Fe3-xTixO4 grains (x ⌠0.6). The large grains in the pure magnetite sample are shown to be pseudo-single domain in nature. The quenching process involved in synthesis is considered similar to that of pillow basalts found at mid-ocean ridges and hence the reaction products are thought ideal in terms of characterization and understanding, for the purpose of studying natural systems
Hydrothermal synthesis, off-axis electron holography and magnetic properties of FeO nanoparticles
The hydrothermal synthesis of Fe3O4 nanoparticles (NPs) (< 50 nm) from mixed FeCl3 / FeCl2 precursor solution at pH ~ 12 has been confirmed using complementary characterisation techniques of transmission electron microscopy and X-ray diffractometry. Off-axis electron holography allowed for visualisation of their single domain (SD) nature, as well as inter-particle interactions, with the latter attributed to explain the pseudo-SD/multi-domain behaviour demonstrated by bulk magnetic measurements
Electron microscopy study of CeOxâPd/α-Al2O3 catalysts for methane dry reforming
We have investigated the interaction between Pd and Ce in a 0.47 wt % CeOxâPd 1 wt %/ -Al2O3 catalyst that is used in the reforming reaction of CH4 with CO2. The freshly reduced catalyst was characterized by various electron microscopy techniques, such as elemental mapping, Z-contrast imaging, and electron energy-loss spectroscopy to understand the role of Ce on a microscopic scale. The high spatial resolution elemental mapping indicates that CeOx is located in close proximity of the palladium nanoparticles. High-resolution lattice images and energy-loss spectra obtained in the vicinity of the Pd particles show an anisotropic distribution of CeOx crystallites limited to the interface region between Pd and the substrate but not covering the surface of the Pd nanoparticles. Energy-loss near edge fine structure of Pd M edges reveals that the Pd nanoparticles are not oxidized.Fil: Moreno, M. S.. ComisiĂłn Nacional de EnergĂa AtĂłmica. Centro AtĂłmico Bariloche; ArgentinaFil: Wang, Feiya. National Institute for Nanotechnology; CanadĂĄFil: Malac, M.. National Institute for Nanotechnology; CanadĂĄFil: Kasama, T.. University of Cambridge; Reino UnidoFil: Gigola, Carlos Eugenio. Consejo Nacional de Investigaciones CientĂficas y TĂ©cnicas. Centro CientĂfico TecnolĂłgico Conicet - BahĂa Blanca. Planta Piloto de IngenierĂa QuĂmica. Universidad Nacional del Sur. Planta Piloto de IngenierĂa QuĂmica; ArgentinaFil: Costilla, Ignacio Oscar. Consejo Nacional de Investigaciones CientĂficas y TĂ©cnicas. Centro CientĂfico TecnolĂłgico Conicet - BahĂa Blanca. Planta Piloto de IngenierĂa QuĂmica. Universidad Nacional del Sur. Planta Piloto de IngenierĂa QuĂmica; ArgentinaFil: SĂĄnchez, M. D.. Universidad Nacional del Sur. Departamento de FĂsica; Argentin
Measurement of the penetration depth and coherence length of MgB2 in all directions using transmission electron microscopy
We demonstrate that images of flux vortices in a superconductor taken with a
transmission electron microscope can be used to measure the penetration depth
and coherence length in all directions at the same temperature and magnetic
field. This is particularly useful for MgB, where these quantities vary
with the applied magnetic field and values are difficult to obtain at low field
or in the -direction. We obtained images of flux vortices from an MgB
single crystal cut in the plane by focussed ion beam milling and tilted to
with respect to the electron beam about its axis. A new method
was developed to simulate these images which accounted for vortices with a
non-zero core in a thin, anisotropic superconductor and a simplex algorithm was
used to make a quantitative comparison between the images and simulations to
measure the penetration depths and coherence lengths. This gave penetration
depths nm and nm at 10.8 K in a
field of 4.8 mT. The large error in is a consequence of tilting
the sample about and had it been tilted about , the errors would be
reversed. Thus, obtaining the most precise values requires taking images of the
flux lattice with the sample tilted in more than one direction. In a previous
paper, we obtained a more precise value using a sample cut in the plane.
Using this value gives nm, nm,
nm and nm which agree well with
measurements made using other techniques. The experiment required two days to
conduct and does not require large-scale facilities. It was performed on a very
small sample: microns and 200 nm thick so this method could prove
useful for characterising new superconductors where only small single crystals
are available.This work was funded by the Royal Society. Work at
Eidgenossische Technische Hochschule, ZĂŒrich was supported
by the Swiss National Science Foundation and the National
Center of Competence in Research programme âMaterials
with Novel Electronic Properties.âThis is the accepted manuscript for a paper published in Physical Review B, 91, 054505, 5 February 2015, DOI: 10.1103/PhysRevB.91.05450
Direct measurement of the charge distribution along a biased carbon nanotube bundle using electron holography
Nanowires and nanotubes can be examined in the transmission electron microscope under an applied bias. Here we introduce a model-independent method, which allows the charge distribution along a nanowire or nanotube to be measured directly from the Laplacian of an electron holographic phase image. We present results from a biased bundle of carbon nanotubes, in which we show that the charge density increases linearly with distance from its base, reaching a value of similar to 0.8 electrons/nm near its tip. (C) 2011 American Institute of Physics. [doi:10.1063/1.3598468
Internet Service Providers' and Individuals' Attitudes, Barriers, and Incentives to Secure IoT
Internet of Things (IoT) play a vital role in securing IoT.
However, encouraging them to do so is hard. Our study investigates ISPsâ and individualsâ attitudes towards the security
of IoT, the obstacles they face, and their incentives to keep
IoT secure, drawing evidence from Japan.
Due to the complex interactions of the stakeholders, we
follow an iterative methodology where we present issues and
potential solutions to our stakeholders in turn. For ISPs, we
survey 27 ISPs in Japan, followed by a workshop with representatives from government and 5 ISPs. Based on the findings
from this, we conduct semi-structured interviews with 20 participants followed by a more quantitative survey with 328
participants. We review these results in a second workshop
with representatives from government and 7 ISPs. The appreciation of challenges by each party has lead to findings that
are supported by all stakeholders.
Securing IoT devices is neither usersâ nor ISPsâ priority.
Individuals are keen on more interventions both from the
government as part of regulation and from ISPs in terms of
filtering malicious traffic. Participants are willing to pay for
enhanced monitoring and filtering. While ISPs do want to help
users, there appears to be a lack of effective technology to
aid them. ISPs would like to see more public recognition for
their efforts, but internally they struggle with executive buy-in
and effective means to communicate with their customers.
The majority of barriers and incentives are external to ISPs
and individuals, demonstrating the complexity of keeping IoT
secure and emphasizing the need for relevant stakeholders in
the IoT ecosystem to work in tandem
MTX and ETN Personal non-commercial use only
ABSTRACT. Objective. The aim of the Efficacy and Safety of Etanercept on Active Rheumatoid Arthritis Despite Methotrexate Therapy in Japan (JESMR) study is to compare the efficacy of continuation versus discontinuation of methotrexate (MTX) when starting etanercept (ETN) in patients with active rheumatoid arthritis (RA). Methods. In total, 151 patients with active RA who had been taking MTX were randomized to either ETN 25 mg twice a week with 6-8 mg/week MTX (the E+M group), or ETN alone (the E group). The primary endpoint at Week 52 was the radiographic progression assessed by van der Heijde-modified Sharp score. Results. The mean progression in total score at Week 52 was not significantly different, statistically, between the E+M group and the E group (0.8 vs 3.6, respectively; p = 0.06). However, a significant difference was observed in radiographic progression between Weeks 24 and 52 (0.3 vs 2.5; p = 0.03), and the mean progression of the erosion score was negative in the E+M group, which was significantly better than the E group at Week 52 (-0.2 vs 1.8; p = 0.02). Clinically, the cumulative probability plot of the American College of Rheumatology (ACR)-N values at Week 52 clearly demonstrated a superior response in the E+M group than in the E group. ACR20, 50, and 70 response rates at Week 52 in the E+M group (86.3%, 76.7%, and 50.7%) were significantly greater than those in the E group (63.8%; p = 0.003, 43.5%; p < 0.0001 and 29.0%; p = 0.01, respectively). Conclusion. MTX should be continued when starting ETN in patients with active RA
Continuation of Methotrexate Resulted in Better Clinical and Radiographic Outcomes Than Discontinuation upon Starting Etanercept in Patients with Rheumatoid Arthritis: 52-week Results from the JESMR Study
ABSTRACT. Objective. The aim of the Efficacy and Safety of Etanercept on Active Rheumatoid Arthritis Despite Methotrexate Therapy in Japan (JESMR) study is to compare the efficacy of continuation versus discontinuation of methotrexate (MTX) when starting etanercept (ETN) in patients with active rheumatoid arthritis (RA). Methods. In total, 151 patients with active RA who had been taking MTX were randomized to either ETN 25 mg twice a week with 6-8 mg/week MTX (the E+M group), or ETN alone (the E group). The primary endpoint at Week 52 was the radiographic progression assessed by van der Heijde-modified Sharp score. Results. The mean progression in total score at Week 52 was not significantly different, statistically, between the E+M group and the E group (0.8 vs 3.6, respectively; p = 0.06). However, a significant difference was observed in radiographic progression between Weeks 24 and 52 (0.3 vs 2.5; p = 0.03), and the mean progression of the erosion score was negative in the E+M group, which was significantly better than the E group at Week 52 (-0.2 vs 1.8; p = 0.02). Clinically, the cumulative probability plot of the American College of Rheumatology (ACR)-N values at Week 52 clearly demonstrated a superior response in the E+M group than in the E group. ACR20, 50, and 70 response rates at Week 52 in the E+M group (86.3%, 76.7%, and 50.7%) were significantly greater than those in the E group (63.8%; p = 0.003, 43.5%; p < 0.0001 and 29.0%; p = 0.01, respectively). Conclusion. MTX should be continued when starting ETN in patients with active RA
- âŠ