122 research outputs found
Hierarchical Control of Production Flow based on Capacity Allocation for Real-Time Scheduling of Manufacturing System
8International audienceThis paper considers the modelling and simulation of a hierarchical production-flow control system. It uses a continuous control approach for machine capacity allocation at the design level and real time scheduling at the shop-floor level. Particularly, at the design level, the control of machine throughput has been addressed by a set of distributed and supervised fuzzy controllers. The objective is to adjust the machine's production rates in such a way that satisfies the demand while maintaining the overall performances within acceptable limits. At the shop-floor level, the problem of scheduling of jobs is considered. In this case, the priority of jobs (actual dispatching times) is determined from the continuous production rates through a discretization procedure. A case study demonstrates the efficiency of the proposed methodology through a simulation case study
Pilotage Flou Distribué et Supervisé pour la Régulation des Flux de Production
National audienceDans cet article, une structure de pilotage distribuée et supervisée pour la régulation des flux de production est proposée. Partant de la décomposition d'un système de production en un ensemble de modules élémentaires, une structure de pilotage distribuée de type multi-contrôleurs est déployée au niveau " local ". A ce niveau, chaque module de production est piloté par un contrôleur flou afin de satisfaire la demande et d'éviter les phénomènes de rupture et de blocage. Afin d'améliorer les performances de cette structure, un niveau de supervision est intégré. Ce dernier a pour rôle de coordonner les actions locales et de réaliser des compromis entre les objectifs globaux. La conception du superviseur s'appuie sur l'exploitation des opérateurs d'agrégation et la quantification des objectifs par des intervalles flous. Un exemple de simulation est considéré pour illustrer les performances de la méthodologie proposée
INTELLIGENT CONTROL IN THE SIMULATION OF MANUFACTURING SYSTEM
International audienceA particular characteristic of a manufacturing system concerns the complexity and the presence of uncertainties along with the difficulties in building analytical models that capture the system in all its important aspects. Hence, simulation remains one of the most widely used tools to fill this need. The objective of this article is related to the potential improvement of computer simulation as applied to the control of manufacturing system by introducing a two-level fuzzy-logic based control structure. On the lower level of the hierarchy, there is an adaptive fuzzy controller for each specific production module which can automatically sythesize itself to regulate the flow of the material into a system, and in the upper level, a supervisor has the task of coordinating and tuning the local controllers by using the performance measurements characterizing the overall system's current behavior to achieve better performance and restrict the system in admissible domain
Supervisory Control based Fuzzy Interval Arithmetic Applied for Discrete Scheduling of Manufacturing Systems
6 pagesInternational audienceThis paper considers the modelling and designing of a production-flow scheduler based on fuzzy interval system. Particularly, the supervisory control is built according to the satisfaction degree of conflicting objectives which are quantified by fuzzy intervals. The control system aims at adjusting the machine's production rates in such a way that satisfies the demand while maintaining the overall performances within acceptable limits. At the shop-floor level, the actual dispatching times are determined from the continuous production rates through a sampling procedure. A decision for the actual part to be processed is taken using some criterions which represent a measure of the job's priority. A case study demonstrates the efficiency of the proposed control approach
Application of a continuous supervisory fuzzy control on a discrete scheduling of manufacturing systems.
10 pagesInternational audienceThis paper considers the modelling and simulation of a hierarchical production-flow control system. Particularly, the system capacity allocation has been addressed by a set of distributed and supervised fuzzy controllers. The objective is to adjust the machine's production rates in such a way that satisfies the demand while maintaining the overall performances within acceptable limits. Given the adjusted production rates, the problem of scheduling of jobs is considered at the shop-floor level. In this case, the actual dispatching times are determined from the continuous production rates through a sampling procedure. To deal with conflicts between jobs at a shared machine, a decision for the actual part to be processed is taken using some criteria which represent a measure of the job's priority. A case study demonstrates the efficiency of the proposed control approach
Construction and characterization of a phototherapy radiometer for optical radiation measurements
It is necessary to measure the irradiance levels to evaluate the effective dose delivered to the neonate from phototherapy devices. For such purpose, a broadband phototherapy radiometer has been used for measuring these phototherapy irradiance doses of plurality types of phototherapy sources. A phototherapy radiometer has been designed and during the construction its optical characteristics has been tested in collaboration between the National Institute of Standards in Egypt (NIS) and Department of Research And Development, Medical Engineering Group (MEG) Company. The most parameters required to characterize the performance of radiometer are the responsivity and uniformity. Then the present radiometer has been compared to other two available portable phototherapy radiometers in irradiance levels measurement. The calibration has been settled and the expanded uncertainties has been calculated according to the Guide to the expression of uncertainty in measurement (GUM) at coverage factor k = 2. The designed radiometer has responsivity range 415-495 nm with FWHM 35 nm which covers the phototherapy blue band. The radiometer results output summarized as; quantum efficiency is 84%, the uniformity 72% and measuring irradiance range 100-2500 µW.cm-2
Neurorétinite unilatérale: une manifestation rare du syndrome post streptococcique
La streptocoque β hémolytique est responsable de plusieurs complications d'origine immunitaire, de localisation cardiaque, articulaire, dermatologique, rénale, cérébrale et oculaire. Nous rapportons le premier cas au Maroc d'une uvéite postérieure unilatérale post- streptococcique présentant une vascularite rétinienne avec oedème papillaire et des hémorragies rétiniennes en tache profondes et superficielles .Notre patient âgé de 56 ans, ayant comme antécédents pathologiques une notion d'angine et d' érythème noueux à répétition d'origine streptococcique. Le bilan étiologique d'uvéite est revenu normal. En revanche, le titrage des anticorps antistreptococciques était significativement élevé: 430 IU /ml. Le patient a été mis sous amoxicilline protégée à une dose de 2 g par jour pendant 10 jours, associée à une corticothérapie à dose régressive sur un mois. L'évolution était favorable avec récupération totale de l'acuité visuelle (AV) et disparition des lésions neurorétiniennesKey words: Vascularite, oedème papillaire, hémorragies rétiniennes, neurorétinite, érythème noueux, streptocoqu
Severe ischemic retinopathy in a patient with systemic lupus erythematosus without antiphospholipid syndrome: A case report
AbstractSystemic lupus erythematosus (SLE) is a chronic, autoimmune, multisystem disease which may affect the eyes and/or visual system in up to a third of patients. Severe retinal vaso-occlusive diseases have been rarely reported as manifestation in patients with SLE. We report the case of a 35-year-old female treated for systemic lupus erythematosus for 6months, presented a sudden loss of vision. Fundus examination and fluorescein angiography revealed severe retinal vascular occlusion. This has motivated the search for antiphospholipid antibody syndrome and this was confirmed without the presence of anticardiolipin antibodies. And the treatment consisted in a laser therapy. The purpose of this case report is to demonstrate that an ocular vascular event can reveal the disease and that its diagnosis is important because this disease generally affects young people and may endanger ocular and vital prognosis
Photokératoconjonctivite par coup d′arc
La photokératite est une kératite douloureuse causée par l'exposition non-protégée des yeux aux rayons ultraviolets (UV). On parle de «coup d'arc» quand la photokératite est induite par le rayonnement UV émis par l′arc électrique pendant le soudage à l′arc électrique. Nous rapportons le cas d′un patient de 35 ans, sans antécédents notables, cavalier de profession qui se dit avoir regardé pendant quelques minutes, un arc électrique durant le soudage des portes du stable suite à laquelle, il a présenté une douleur oculaire bilatérale à type de brûlure associé à des larmoiements photophobie et blépharospasme. Son examen clinique a montré une acuité visuelle avec correction à 8/10 et 9/10, une hyperhémie conjonctivale avec une kératite érosive ponctuée limité à la fente palpébrale après instillation de la fluorescéine. Vu le contexte, le diagnostic d'une kératoconjonctivite par coup d'arc a été retenu. Le patient a été mis sous antibiotique topique, agents mouillants et cicatrisants. L′évolution a été marquée, par la disparition totale des signes avec une acuité visuelle qui est remonté à 10/10 en bilatérale. A travers ce cas, on illustre l′intérêt d′une prévention par un port d′équipements de protection adaptés
Céphalée : faut-il demander une imagerie ?
La céphalée est un motif fréquent de consultation. Elle est primaire dans la majorité des cas et ne nécessite aucune exploration radiologique, et moins fréquemment secondaire en rapport des étiologies très variées. Dans cet article, à travers trois observations cliniques, les auteurs mettent le point sur les indications de l’imagerie devant les céphalées, ceci afin d’éviter les retards du diagnostic des céphalées secondaires pouvant aboutir à des séquelles parfois irréversibles notamment ophtalmologiques
- …