7 research outputs found

    Study of Photon Strength Function of Actinides : the Case of U-235, Np-238 and Pu-241

    Full text link
    The decay from excited levels in medium and heavy nuclei can be described in a statistical approach by means of Photon Strength Functions and Level Density distributions. The study of electromagnetic cascades following neutron capture based on the use of high efficiency detectors has been shown to be well suited for probing the properties of the Photon Strength Function of heavy (high level density) and/or radioactive (high background) nuclei. In this work we have investigated for the first time the validity of the recommended PSF of actinides, in particular U-235, Np-238 and Pu-241. Our study includes the search for resonance structures in the PSF below S-n and draws conclusions regarding their existence and their characteristics in terms of energy, width and electromagnetic nature.Peer reviewe

    Neutron Capture Measurements on Minor Actinides at the n_TOF Facility at CERN : Past, Present and Future

    Full text link
    The successful development of advanced nuclear systems for sustainable energy production and nuclear waste management depends on high quality nuclear data libraries. Recent sensitivity studies and reports [1-3] have identified the need for substantially improving the accuracy of neutron cross-section data for minor actinides. The n_TOF collaboration has initiated an ambitious experimental program for the measurement of neutron capture cross sections of minor actinides. Two experimental setups have been constructed for this purpose: a Total Absorption Calorimeter (TAC) [4] for measuring neutron capture cross-sections of low-mass and/or radioactive samples and a set of two low neutron sensitivity C(6)D(6) detectors for the less radioactive materials.Peer reviewe

    The Role of Fe and Ni for S-process Nucleosynthesis and Innovative Nuclear Technologies

    Full text link
    The accurate measurement of neutron capture cross sections of all Fe and Ni isotopes is important for disentangling the contribution of the s-process and the r-process to the stellar nucleosynthesis of elements in the mass range 60 < A < 120. At the same time, Fe and Ni are important components of structural materials and improved neutron cross section data is relevant in the design of new nuclear systems. With the aim of obtaining improved capture data on all stable iron and nickel isotopes, a program of measurements has been launched at the CERN Neutron Time of Flight Facility n_TOF

    Characterization of the New n TOF Neutron Beam: Fluence, Profile and Resolution

    Full text link
    kein Abstract verfügba

    Improved Neutron Capture Cross Section Measurements with the n_TOF Total Absorption Calorimeter

    Full text link
    The n_TOF collaboration operates a Total Absorption Calorimeter (TAC) [1] for measuring neutron capture cross-sections of low-mass and/or radioactive samples. The results obtained with the TAC have led to a substantial improvement of the capture cross sections of (237)Np and (240)Pu [2]. The experience acquired during the first measurements has allowed us to optimize the performance of the TAC and to improve the capture signal to background ratio, thus opening the way to more complex and demanding measurements on rare radioactive materials. The new design has been reached by a series of detailed Monte Carlo simulations of complete experiments and dedicated test measurements. The new capture setup will be presented and the main achievements highlighted

    Measurement of the 24,25,26 Mg (n,gamma) reaction cross-section at n_TOF

    Full text link

    New measurement of the astrophysically important reaction 62Ni(n,gamma) at n_TOF

    Full text link
    corecore