273 research outputs found

    Heavy-Fermions in LiV2O4: Kondo-Compensation vs. Spin-Liquid Behavior?

    Full text link
    7Li NMR measurements were performed in the metallic spinel LiV2O4. The temperature dependencies of the line width, the Knight shift and the spin-lattice relaxation rate were investigated in the temperature range 30 mK < T < 280 K. For temperatures T < 1 K we observe a spin-lattice relaxation rate which slows down exponentially. The NMR results can be explained by a spin-liquid behavior and the opening of a spin gap of the order 0.6 K

    Treatment of focal degenerative cartilage defects with polymer-based autologous chondrocyte grafts: four-year clinical results

    Get PDF
    INTRODUCTION: Second-generation autologous chondrocyte implantation with scaffolds stabilizing the grafts is a clinically effective procedure for cartilage repair. In this ongoing prospective observational case report study, we evaluated the effectiveness of BioSeed-C, a cell-based cartilage graft based on autologous chondrocytes embedded in fibrin and a stable resorbable polymer scaffold, for the treatment of clinical symptomatic focal degenerative defects of the knee. METHODS: Clinical outcome after 4-year clinical follow-up was assessed in 19 patients with preoperatively radiologically confirmed osteoarthritis and a Kellgren-Lawrence score of 2 or more. Clinical scoring was performed before implantation of the graft and 6, 12, and 48 months after implantation using the Lysholm score, the Knee injury and Osteoarthritis Outcome Score (KOOS), the International Knee Documentation Committee (IKDC) score, and the International Cartilage Repair Society (ICRS) score. Cartilage regeneration and articular resurfacing were assessed by magnetic resonance imaging (MRI) 4 years after implantation of the autologous cartilage graft. RESULTS: Significant improvement (P < 0.05) of the Lysholm and ICRS scores was observed as early as 6 months after implantation of BioSeed-C and remained stable during follow-up. The IKDC score showed significant improvement compared with the preoperative situation at 12 and 48 months (P < 0.05). The KOOS showed significant improvement in the subclasses pain, activities of daily living, and knee-related quality of life 6 months as well as 1 and 4 years after implantation of BioSeed-C in osteoarthritic defects (P < 0.05). MRI analysis showed moderate to complete defect filling with a normal to incidentally hyperintense signal in 16 out of 19 patients treated with BioSeed-C. Two patients without improvement in the clinical and MRI scores received a total knee endoprosthesis after 4 years. CONCLUSIONS: The results show that the good clinical outcome achieved 1 year after implantation of BioSeed-C remains stable over the course of a period of 4 years and suggest that implanting BioSeed-C is a promising treatment option for the repair of focal degenerative defects of the knee

    An Evaluation of Cross-Efficiency Methods, Applied to Measuring Warehouse Performance

    Get PDF
    In this paper method and practice of cross-efficiency calculation is discussed. The main methods proposed in the literature are tested not on a set of artificial data but on a realistic sample of input-output data of European ware- houses. The empirical results show the limited role which increasing automation investment and larger warehouse size have in increasing productive performance. The reason is the existence of decreasing returns to scale in the industry, resulting in sub-optimal scales and inefficiencies, regardless of the operational performance of the facilities. From the methodological perspective, and based on a multidimensional metric which considers the capability of the various methods to rank warehouses, their ease of implementation, and their robustness to sensitivity analyses, we conclude to the superiority of the classic Sexton et al. (1986) method over recently proposed, more sophisticated methods

    Treatment of posttraumatic and focal osteoarthritic cartilage defects of the knee with autologous polymer-based three-dimensional chondrocyte grafts: 2-year clinical results

    Get PDF
    Autologous chondrocyte implantation (ACI) is an effective clinical procedure for the regeneration of articular cartilage defects. BioSeed®-C is a second-generation ACI tissue engineering cartilage graft that is based on autologous chondrocytes embedded in a three-dimensional bioresorbable two-component gel-polymer scaffold. In the present prospective study, we evaluated the short-term to mid-term efficacy of BioSeed-C for the arthrotomic and arthroscopic treatment of posttraumatic and degenerative cartilage defects in a group of patients suffering from chronic posttraumatic and/or degenerative cartilage lesions of the knee. Clinical outcome was assessed in 40 patients with a 2-year clinical follow-up before implantation and at 3, 6, 12, and 24 months after implantation by using the modified Cincinnati Knee Rating System, the Lysholm score, the Knee injury and Osteoarthritis Outcome Score, and the current health assessment form (SF-36) of the International Knee Documentation Committee, as well as histological analysis of second-look biopsies. Significant improvement (p < 0.05) in the evaluated scores was observed at 1 and/or 2 years after implantation of BioSeed-C, and histological staining of the biopsies showed good integration of the graft and formation of a cartilaginous repair tissue. The Knee injury and Osteoarthritis Outcome Score showed significant improvement in the subclasses pain, other symptoms, and knee-related quality of life 2 years after implantation of BioSeed-C in focal osteoarthritic defects. The results suggest that implanting BioSeed-C is an effective treatment option for the regeneration of posttraumatic and/or osteoarthritic defects of the knee

    Staggered magnetism in LiV2_2O4_4 at low temperatures probed by the muon Knight shift

    Full text link
    We report on the muon Knight shift measurement in single crystals of LiV2O4. Contrary to what is anticipated for the heavy-fermion state based on the Kondo mechanism, the presence of inhomogeneous local magnetic moments is demonstrated by the broad distribution of the Knight shift at temperatures well below the presumed "Kondo temperature" (T∗≃30T^*\simeq 30 K). Moreover, a significant fraction (≃10\simeq10 %) of the specimen gives rise to a second component which is virtually non-magnetic. These observations strongly suggest that the anomalous properties of LiV2O4 originates from frustration of local magnetic moments.Comment: 11 pages, 5 figures, sbmitted to J. Phys.: Cond. Mat

    Factors associated with shunt dynamic in patients with cryptogenic stroke and patent foramen ovale: an observational cohort study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>As previously reported there is evidence for a reduction in right to left shunt (RLS) in stroke patients with patent foramen ovale (PFO). This occurs predominantly in patients with cryptogenic stroke (CS). We therefore analysed factors associated with a shunt reduction on follow-up in stroke patients suffering of CS.</p> <p>Methods</p> <p>On index event PFO and RLS were proven by transesophageal echocardiography and contrast-enhanced transcranial Doppler-sonography (ce-TCD). Silent PE was proved by ventilation perfusion scintigraphy (V/Q) within the stroke work-up on index event; all scans were re-evaluated in a blinded manner by two experts. The RLS was re-assessed on follow-up by ce-TCD. A reduction in shunt volume was defined as a difference of ≥20 microembolic signals (MES) or the lack of evidence of RLS on follow-up. For subsequent analyses patients with CS were considered; parameters such as deep vein thrombosis (DVT) and silent pulmonary embolism (PE) were analysed.</p> <p>Results</p> <p>In 39 PFO patients suffering of a CS the RLS was re-assessed on follow-up. In all patients (n = 39) with CS a V/Q was performed; the median age was 40 years, 24 (61.5%) patients were female. In 27 patients a reduction in RLS was evident. Silent PE was evident in 18/39 patients (46.2%). Factors such as atrial septum aneurysm, DVT or even silent PE were not associated with RLS dynamics. A greater time delay from index event to follow-up assessment was associated with a decrease in shunt volume (median 12 vs. 6 months, <it>p </it>= 0.013).</p> <p>Conclusions</p> <p>In patients with CS a reduction in RLS is not associated with the presence of a venous embolic event such as DVT or silent PE. A greater time delay between the initial and the follow-up investigation increases the likelihood for the detection of a reduction in RLS.</p
    • …
    corecore