19 research outputs found

    Cerebral iodized lipid embolization via a pulmonary arteriovenous shunt: rare complication of transcatheter arterial embolization for hepatocellular carcinoma

    Get PDF
    We report the first European case of cerebral iodized lipid embolism post transcatheter arterial embolization for hepatocellular carcinoma. Lipiodol emboli and corresponding multifocal brain ischemia were documented with computed tomography (CT) and magnetic resonance (MR) in the acutely symptomatic patient. Transcranial Doppler sonography with contrast indicated a right-to-left shunt, while on a follow-u

    Diffusion weighted magnetic resonance imaging demonstrates tumor response following palliative embolization of a recurrent shoulder plasmacytoma

    Get PDF
    We report the palliative embolization and functional imaging follow-up of a recurrent shoulder plasmacytoma. The multiple myeloma patient complained of severe pain and discomfort, while he could not tolerate further chemotherapy. The left shoulder lesion had earlier received a high dose of irradiation. Thus, the well-vascularized lesion was embolized via feeding arteries branching off from the left subclavian artery in two sessions. The patient's symptoms rapidly improved post-embolization and the serum free light chain ratio stabilized at a lower level. The follow-up magnetic resonance image showed increased diffusivity in previously restricted tumor foci. This has negatively correlated with the decreased fludeoxyglucose uptake on PET, suggesting post-embolization necrosis

    Interobserver agreement and diagnostic accuracy of shearwave elastography for the staging of hepatitis C virus-associated liver fibrosis

    Get PDF
    Abstract PURPOSE: Our study aimed to evaluate the technical success rate, interobserver reproducibility, and accuracy of shearwave elastography (SWE) in the staging of hepatitis C virus (HCV)-associated liver fibrosis. METHODS: A total of 10 healthy controls and 49 patients with chronic liver disease were enrolled prospectively. Two examiners performed point shearwave elastography (pSWE) and two-dimensional shearwave elastography (2D-SWE) measurements with an RS85A ultrasound scanner using the S-Shearwave application (Samsung Medison, Hongcheon, Korea). The performance of S-Shearwave in the staging (METAVIR F0-F4) of liver fibrosis was compared with prior transient elastography (TE) with receiver operating characteristic (ROC) curve analysis. RESULTS: The interobserver reproducibility was excellent with pSWE (ICC = 0.92, 95% CI: 0.86-0.95, P < .001). A very good agreement was found between pSWE and TE measurements (ICC =0.85, 95% CI: 0.78-0.89, P < .001). The ROC analysis determined the optimal cut-off values of pSWE for the staging of chronic hepatitis C-associated fibrosis (F2, 1.46 m/s; F3, 1.63 m/s; F4, 1.95 m/s). Both observers achieved excellent diagnostic accuracy (AUROC: 94% vs 97%) in the detection of significant (≥F2) liver fibrosis. CONCLUSION: The interobserver agreement is excellent with S-Shearwave pSWE, and observers can diagnose significant liver fibrosis with a comparable accuracy to TE

    Prognostic value of pre-embolisation MRI features of uterine fibroids in uterine artery embolisation

    No full text
    Abstract AIM: To evaluate the prognostic value of pretreatment pelvic magnetic resonance imaging (MRI) features in uterine artery embolisation (UAE) for symptomatic fibroids. MATERIALS AND METHODS: MRI characteristics of 109 fibroids (≥3 cm) in 70 patients were analysed retrospectively. Imaging was performed 1.8±1.3 (SD) months before and 6.6±1.8 months after UAE. On pretreatment images, signal intensity (SI) of fibroids was compared with that of the myometrium and skeletal muscle on T1- and T2-weighted sequences; the contrast enhancement pattern and localisation of fibroids were also analysed. Fibroid volume reduction (VR) was assessed by control imaging. The numerical analogue quality-of-life score was obtained before and after UAE. Statistical analysis was performed using the Mann-Whitney U-test, Kruskal-Wallis test, and Wilcoxon signed-rank test. RESULTS: The mean fibroid volume decreased by 51.1±30.8% during the 6.6±1.8 months (p<0.001). Mean quality-of-life score improved by 48.2±27.6 points (p<0.001). The mean VR of submucosal fibroids (82.1±18.5%) was greater than that of intramural (49.4±30.7%) and subserosal (43±28.3%) fibroids (p<0.001 for both). Fibroids that were isointense/hyperintense to myometrium on T2-weighted images showed a better response than hypointense fibroids (63.7±25.8% versus 48.6±31.3%, respectively; p=0.041). On contrast-enhanced images, isointense/hyperintense fibroids showed a better VR than hypointense fibroids (61.3±27.4% versus 47.6±31.6%, respectively; p=0.035). Baseline fibroid volume of <50 cm3 was also associated with favourable imaging outcome (p=0.021). T2 SI compared to skeletal muscle and T1 SI compared to myometrium or skeletal muscle did not show association with VR. CONCLUSIONS: Localisation, T2 SI, contrast enhancement, and <50 cm3 fibroid volume were associated with better VR; these may help with treatment decisions

    High frequency of brachiocephalic trunk stent fractures does not impair clinical outcome

    Get PDF
    Abstract OBJECTIVE: Stenting is the preferred, minimally invasive treatment for innominate artery (IA) stenosis or occlusion. Stent fractures in the IA have not been assessed in larger cohorts. In this retrospective study, we examined the frequency and risk factors of IA stent fractures. METHODS: The final analysis included 32 patients (15 women; mean age, 59.4 ± 12.0 years) with 32 balloon-expandable stents (2000 to 2009). In 2010, the patients were asked to come back for a fluoroscopic examination of the implanted stents. Stent fractures and their relationship to atherosclerotic risk factors, lesion characteristics, postprocedural symptoms, and in-stent restenosis were analyzed. Fisher exact test and univariate Cox regression analysis were used in the statistical evaluation. RESULTS: Lesions were >20 mm in 14 patients (44%) or heavily calcified in 13 (41%). The mean follow-up time was 33.4 ± 21.0 months. Postprocedural symptoms were noted in nine patients (28%). Significant restenosis was detected in 22% of the implanted stents, and 11 stent fractures (34%) were found. The prevalence of heavily calcified lesions, postprocedural symptoms, and in-stent restenosis did not differ significantly between groups with and without fracture. Long lesions were associated with an increased incidence of stent fracture (hazard ratio, 5.09; 95% confidence interval, 1.33-19.48; P = .017). No correlation was observed between stent fractures and old age (≥70 years), female gender, smoking, hypertension, hyperlipidemia, or diabetes mellitus. CONCLUSIONS: IA stent fractures are common but seem to have no effect on symptoms and in-stent restenosis rates

    Comparison of Vendor-Independent Software Tools for Liver Proton Density Fat Fraction Estimation at 1.5 T

    No full text
    (1) Background: Open-source software tools are available to estimate proton density fat fraction (PDFF). (2) Methods: We compared four algorithms: complex-based with graph cut (GC), magnitude-based (MAG), magnitude-only estimation with Rician noise modeling (MAG-R), and multi-scale quadratic pseudo-Boolean optimization with graph cut (QPBO). The accuracy and reliability of the methods were evaluated in phantoms with known fat/water ratios and a patient cohort with various grades (S0–S3) of steatosis. Image acquisitions were performed at 1.5 Tesla (T). (3) Results: The PDFF estimates showed a nearly perfect correlation (Pearson r = 0.999, p p p p = 0.005) were lower than MAG-R. The field inhomogeneity artifacts were most frequent in MAG-R (70%) and GC (39%) and absent in QPBO images. (4) Conclusions: The tested algorithms all accurately estimate PDFF in vitro. Meanwhile, QPBO is the least affected by field inhomogeneity artifacts in vivo
    corecore