22 research outputs found

    Liver on a Chip; Engineering the Liver Sinusoid

    Full text link
    We have developed a novel microfluidic device using poly-dimethylsiloxane (PDMS) microchannels for long term, layered co-culture of primary rat hepatocytes (PRH) and endothelial cells (EC) to mimic the liver sinusoid. Three microfluidic configurations were investigated as shown in Figure 1. In configuration 1, where PRH and rat adrenal medullary endothelial cells (RAMEC) were cocultured with matrigel in layers in a single PDMS microchannel, cells remained viable for 30 days. In configuration 3, where PRH and liver sinusoidal endothelial cells (LSEC) were cultured on the opposite sides of the microporous membrane between two microchannels under static and dynamic conditions, PRH retained their viability and normal morphology up to 35 days and 63 days, respectively. Thus, our novel liver models that closely mimic the liver sinusoid have been proven to facilitate long-term layered co-cultures of PRH and EC

    Simulating the Effect of Gut Microbiome on Cancer Cell Growth Using a Microfluidic Device

    Full text link
    The imbalance in the gut microbiome plays a vital role in the progression of many dis-eases, including cancer, due to increased inflammation in the body. Since gut microbiome-induced inflammation can serve as a novel therapeutic strategy, there is an increasing need to identify novel approaches to investigate the effect of inflammation instigated by gut microbiome on cancer cells. However, there are limited biomimetic co-culture systems that allow testing of the causal relationship of the microbiome on cancer cells. Here we developed a microfluidic chip that can simulate the inter-action of the gut microbiome and cancer cells to investigate the effects of bacteria and inflammatory stress on cancer cells in vitro. To test the microfluidic chip, we used colorectal cancer cells, as an increased microbiome abundance has been associated with poor outcomes in colorectal cancer. We cultured colorectal cancer cells with Bacillus bacteria or lipopolysaccharide (LPS), a purified bacterial membrane that induces a significant inflammatory response, in the microfluidic device. Our results showed that both LPS and Bacillus significantly accelerated the growth of colorectal cancer cells, therefore supporting that the increased presence of certain bacteria promotes cancer cell growth. The microfluidic device included in this study may have significant implications in identifying new treatments for various cancer types in the future

    Layered Long Term Co-Culture of Hepatocytes and Endothelial Cells on a Transwell Membrane: Toward Engineering the Liver Sinusoid

    Full text link
    This paper presents a novel liver model that mimics the liver sinusoid where most liver activities occur. A key aspect of our current liver model is a layered co-culture of primary rat hepatocytes (PRHs) and primary rat liver sinusoidal endothelial cells (LSECs) or bovine aortic endothelial cells (BAECs) on a transwell membrane. When a layered co-culture was attempted with a thin matrigel layer placed between hepatocytes and endothelial cells to mimic the Space of Disse, the cells did not form completely separated monolayers. However, when hepatocytes and endothelial cells were cultured on the opposite sides of a transwell membrane, PRHs co-cultured with LSECs or BAECs maintained their viability and normal morphology for 39 and 57 days, respectively. We assessed the presence of hepatocyte-specific differentiation markers to verify that PRHs remained differentiated in the long-term co-culture and analyzed hepatocyte function by monitoring urea synthesis. We also noted that the expression of cytochrome P-450 remained similar in the cocultured system from Day 13 to Day 48. Thus, our novel liver model system demonstrated that primary hepatocytes can be cultured for extended times and retain their hepatocyte-specific functions when layered with endothelial cells

    Metabolic Patterning on a Chip: Towards in vitro Liver Zonation of Primary Rat and Human Hepatocytes

    Full text link
    An important number of healthy and diseased tissues shows spatial variations in their metabolic capacities across the tissue. The liver is a prime example of such heterogeneity where the gradual changes in various metabolic activities across the liver sinusoid is termed as “zonation” of the liver. Here, we introduce the Metabolic Patterning on a Chip (MPOC) platform capable of dynamically creating metabolic patterns across the length of a microchamber of liver tissue via actively enforced gradients of various metabolic modulators such as hormones and inducers. Using this platform, we were able to create continuous liver tissues of both rat and human origin with gradually changing metabolic activities. The gradients we have created in nitrogen, carbohydrate and xenobiotic metabolisms recapitulated an in vivo like zonation and zonal toxic response. Beyond its application in recapitulation of liver zonation in vitro as we demonstrate here, the MPOC platform can be used and expanded for a variety of purposes including better understanding of heterogeneity in many different tissues during developmental and adult stages

    Progressive Hypoxia-on-a-chip: An In Vitro Oxygen Gradient Model for Capturing the Effects of Hypoxia on Primary Hepatocytes in Health and Disease

    Full text link
    Oxygen is vital to the function of all tissues including the liver and lack of oxygen, that is, hypoxia can result in both acute and chronic injuries to the liver in vivo and ex vivo. Furthermore, a permanent oxygen gradient is naturally present along the liver sinusoid, which plays a role in the metabolic zonation and the pathophysiology of liver diseases. Accordingly, here, we introduce an in vitro microfluidic platform capable of actively creating a series of oxygen concentrations on a single continuous microtissue, ranging from normoxia to severe hypoxia. This range approximately captures both the physiologically relevant oxygen gradient generated from the portal vein to the central vein in the liver, and the severe hypoxia occurring in ischemia and liver diseases. Primary rat hepatocytes cultured in this microfluidic platform were exposed to an oxygen gradient of 0.3–6.9%. The establishment of an ascending hypoxia gradient in hepatocytes was confirmed in response to the decreasing oxygen supply. The hepatocyte viability in this platform decreased to approximately 80% along the hypoxia gradient. Simultaneously, a progressive increase in accumulation of reactive oxygen species and expression of hypoxia‐inducible factor 1α was observed with increasing hypoxia. These results demonstrate the induction of distinct metabolic and genetic responses in hepatocytes upon exposure to an oxygen (/hypoxia) gradient. This progressive hypoxia‐on‐a‐chip platform can be used to study the role of oxygen and hypoxia‐associated molecules in modeling healthy and injured liver tissues. Its use can be further expanded to the study of other hypoxic tissues such as tumors as well as the investigation of drug toxicity and efficacy under oxygen‐limited conditions

    Flow-Induced Voltage Generation Over Monolayer Graphene in the Presence of Herringbone Grooves

    Full text link
    While flow-induced voltage over a graphene layer has been reported, its origin remains unclear. In our previous study, we suggested different mechanisms for different experimental configurations: phonon dragging effect for the parallel alignment and an enhanced out-of-plane phonon mode for the perpendicular alignment (Appl. Phys. Lett. 102:063116, 2011). In order to further examine the origin of flow-induced voltage, we introduced a transverse flow component by integrating staggered herringbone grooves in the microchannel. We found that the flow-induced voltage decreased significantly in the presence of herringbone grooves in both parallel and perpendicular alignments. These results support our previous interpretation

    Liver Sinusoid on a Chip: Long-Term Layered Co-Culture of Primary Rat Hepatocytes and Endothelial Cells in Microfluidic Platforms

    Full text link
    We describe the generation of microfluidic platforms for the co-culture of primary hepatocytes and endothelial cells; these platforms mimic the architecture of a liver sinusoid. This paper describes a progressional study of creating such a liver sinusoid on a chip system. Primary rat hepatocytes (PRHs) were co-cultured with primary or established endothelial cells in layers in single and dual microchannel configurations with or without continuous perfusion. Cell viability and maintenance of hepatocyte functions were monitored and compared for diverse experimental conditions. When primary rat hepatocytes were co-cultured with immortalized bovine aortic endothelial cells (BAECs) in a dual microchannel with continuous perfusion, hepatocytes maintained their normal morphology and continued to produce urea for at least 30 days. In order to demonstrate the utility of our microfluidic liver sinusoid platform, we also performed an analysis of viral replication for the hepatotropic hepatitis B virus (HBV). HBV replication, as measured by the presence of cell-secreted HBV DNA, was successfully detected. We believe that our liver model closely mimics the in vivo liver sinusoid and supports long-term primary liver cell culture. This liver model could be extended to diverse liver biology studies and liver-related disease research such as drug induced liver toxicology, cancer research, and analysis of pathological effects and replication strategies of various hepatotropic infectious agents

    Layered Hepatocytes and Endothelial Cells on a Transwell Membrane: Toward Engineering the Liver Sinusoid

    Full text link
    This paper presents a novel liver model that mimics the liver sinusoid where most liver activities occur. A key aspect of our current liver model is a layered co-culture of primary rat hepatocytes (PRHs) and primary rat liver sinusoidal endothelial cells (LSECs) or bovine aortic endothelial cells (BAECs) on a transwell membrane. When a layered co-culture was attempted with a thin Matrigel layer placed between hepatocytes and endothelial cells to mimic the space of Disse, the cells did not form completely separated monolayers. However, when hepatocytes and endothelial cells were cultured on the opposite sides of a transwell membrane, PRHs co-cultured with LSECs or BAECs maintained their viability and normal morphology for 39 and 57 days, respectively. We assessed the presence of hepatocyte-specific differentiation markers to verify that PRHs remained differentiated in the long-term co-culture and analyzed hepatocyte function by monitoring urea synthesis. We also noted that the expression of cytochrome P-450 remained similar in the co-cultured system from day 1 to day 48. Thus, our novel liver model system demonstrated that primary hepatocytes can be cultured for extended times and retain their hepatocyte-specific functions when layered with endothelial cells

    Characterization of GDP-mannose Pyrophosphorylase from Escherichia Coli O157:H7 EDL933 and Its Broad Substrate Specificity

    Full text link
    GDP-mannose pyrophosphorylase gene (ManC) of Escherichia coli (E. coli) O157 was cloned and expressed as a highly soluble protein in E. coli BL21 (DE3). The enzyme was subsequently purified using hydrophobic and ion exchange chromatographies. ManC showed very broad substrate specificities for four nucleotides and various hexose-1-phosphates, yielding ADP-mannose, CDP-mannose, UDP-mannose, GDP-mannose, GDP-glucose and GDP-2-deoxy-glucose

    Preparative Synthesis of dTDP-L-Rhamnose Through Combined Enzymatic Pathways

    Full text link
    dTDP-L-rhamnose, an important precursor of O-antigen, was prepared on a large scale from dTMP by executing an one-pot reaction in which six enzymes are involved. Two enzymes, dTDP-4-keto-6-deoxy-D-glucose 3,5-epimerase and dTDP-4-keto-rhamnose reductase, responsible for the conversion of dTDP-4-keto-6-deoxy- D-glucose to dTDP-L-rhamnose, were isolated from their putative sequences in the genome of Mesorhizobium loti, functionally expressed in Escherichia coli, and their enzymatic activities were identified. The two enzymes were combined with an enzymatic process for dTDP-4- keto-6-deoxy-D-glucose involving TMP kinase, acetate kinase, dTDP-glucose synthase, and dTDP-glucose 4,6- dehydratase, which allowed us to achieve a preparative scale synthesis of dTDP-L-rhamnose using dTMP and glucose-1-phosphate as starting materials. About 82% yield of dTDP-L-rhamnose was obtained based on initial dTMP concentration at 20 mM dTMP, 1 mM ATP, 10 mM NADH, 60 mM acetyl phosphate, and 80 mM glucose-1- phosphate. From the reaction with 20 ml volume, approximately 180 mg of dTDP-L-rhamnose was obtained in an overall yield of 60% after two-step purification, that is, anion exchange chromatography and gel filtration for desalting. The purified product was identifiedbyHPLC, ESI-MS,andNMR,showingabout95%purity
    corecore